Commit Graph

270 Commits

Author SHA1 Message Date
Seth Hillbrand f73039cb18 Fix wire endings both too small and too large
Junctions should only be wire endings when ending directly on the wire.
This is the requirement for netlisting, so we need to follow it in the
auto-end as well.

SCH_LABEL needs to allow ending because any wire that touches the label
will be connected, so there's a use case for this.  However, the
bounding box for local labels did not include their connection point, so
we increase that box a bit.  Note that this might have the opposite
effect to https://gitlab.com/kicad/code/kicad/-/issues/7689

Fixes https://gitlab.com/kicad/code/kicad/issues/7714
2021-02-25 16:27:05 -08:00
Wayne Stambaugh 1786ae8773 Eeschema: use symbol nomenclature for object file naming. 2021-02-24 08:48:02 -05:00
Jeff Young 7e2b0e63f1 Fix junction logic when splitting two wires. 2021-02-23 21:43:41 +00:00
Jeff Young d70cebcd62 Allow clicking on terminal point to finish a bus unfold.
Fixes https://gitlab.com/kicad/code/kicad/issues/7413
2021-02-07 00:31:00 +00:00
Jeff Young 1c6c0bf8cf Null-ptr safety.
Fixes https://gitlab.com/kicad/code/kicad/issues/7266
2021-02-02 23:09:35 +00:00
Jeff Young bbb8173b61 Remove and re-add saved-as libraries when Syncing tree.
Also removes the aForce parameter as it was always true anyway.

Fixes https://gitlab.com/kicad/code/kicad/issues/7357
2021-01-31 23:00:17 +00:00
Jeff Young dfc6070178 Unify schematic file version checking with PCBNew.
This also makes sure that the user gets a warning before saving over
an older s-expr format.  While that won't always be wanted, it's now
in the infobar (like in PCBNew), so it's not too onerous.§

Fixes https://gitlab.com/kicad/code/kicad/issues/7347
2021-01-31 17:28:14 +00:00
Mikolaj Wielgus 8eca23aabe Mark null project initial screen as zoom-initialized
The variable `m_Initialized` in `BASE_SCREEN` is used by
`SCH_EDIT_FRAME` to mark whether a screen had its zoom level initialized
by the "zoom to fit screen" action. When this variable is `false`, the
function `SCH_EDIT_FRAME::DisplayCurrentSheet()` performs "zoom to fit
screen", modifying the zoom level. This function is indirectly called in
the undo routines, so if `m_Initialized` is not set to `true`, a zoom
change will occur when the user undoes an operation, a behavior that is
undesired.

`m_Initialized` was not initialized to `true` for the null schematic
(the schematic that is loaded if no project is loaded), causing the
aforementioned undesired behavior.

To prevent this, I've changed the `SCH_EDIT_FRAME` constructor to set
`m_Initialized` to `true`, since it zooms to fit screen already. I've
moved `m_Initialized` from `BASE_SCREEN` to `SCH_SCREEN`, as it is used
only in Eeschema, and renamed it to `m_zoomInitialized`, a name I
believe that better describes what this variable does.

I've also introduced the function `SCH_EDIT_FRAME::initScreenZoom()` to
group the "zoom to fit screen" action with setting `m_Initialized` to
`true`, as they often should occur together.

I'd also like to say that I'm not confident whether
`SCH_EDIT_FRAME::DisplayCurrentSheet()` should perform the zoom level
initialization at this point, but I have decided to not change this
behavior for now, as the commit history suggests it's several years old.

Fixes https://gitlab.com/kicad/code/kicad/issues/7343
2021-01-31 00:49:11 +00:00
Jeff Young ff7742c6b8 File naming and include cleanup. 2021-01-28 11:35:18 +00:00
jean-pierre charras e10025db64 Hierarchy navigation: keep the last used zoom level in a sheet when go back to this sheet.
Fixes #7107
https://gitlab.com/kicad/code/kicad/issues/7107
2021-01-17 09:41:49 +01:00
Dominik Wernberger dc02ec9758 Remove a few const_cast 2021-01-12 20:51:31 +00:00
Dominik Wernberger bb2881a5ab Make RENDER_SETTINGS argument const 2021-01-12 20:51:31 +00:00
jean-pierre charras e66451c56e I18n: remove useless trailing spaces in strings. 2020-12-28 08:43:47 +01:00
Jon Evans 0830f87ef4 Break wire segments on bus-wire entry endpoints
Fixes https://gitlab.com/kicad/code/kicad/-/issues/6173
2020-12-20 10:22:59 -05:00
Jeff Young 92db1d35e1 Formatting. 2020-12-15 17:11:14 +00:00
Jeff Young 126d40f9d3 "Sheet label" too confusing w/ sheet names and fields. Use "sheet pin". 2020-12-13 22:43:09 +00:00
Jeff Young ad281f7538 Remove duplicated TestDanglingEnds routines.
Also adds a changedItemHandler so that the single remaining version
can update the view.

Fixes https://gitlab.com/kicad/code/kicad/issues/6581
2020-12-06 21:24:16 +00:00
Roberto Fernandez Bautista afcaa60faa Remove "Order" field hack (partly reverts da1a89fc) 2020-11-30 16:49:33 +00:00
Jeff Young 8c5c902fa3 Re-write IntersheetRefs on top of SCH_FIELDs and textVars.
1) Generalize SCH_ITEM owners (SCH_COMPONENT, SCH_SHEET, and now
SCH_GLOBALLABEL)
2) Generalize hypertext items
3) Use SCH_FIELD autoplace infrastructure for placing intersheet
references
4) Use textVar infrastructure for buildin intersheet references.

As an important side-effect this also fixes the undo issues with
intersheet refs.
2020-11-17 16:05:49 +00:00
Jeff Young b227d2b910 More component -> symbol. 2020-11-15 20:23:15 +00:00
Jeff Young f0d0e17aab Prepare for MODULE -> FOOTPRINT. 2020-11-13 15:16:24 +00:00
Jeff Young bddc97df30 LibEdit -> SymbolEditor 2020-10-31 10:28:21 +00:00
Wayne Stambaugh 8ff51d8899 Eeschema: add schematic sheet page number.
The groundwork has now been laid for per sheet instance data.  Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.

ADDED: Support for user defined schematic page numbers.
2020-10-19 14:05:45 -04:00
jean-pierre charras 7865d8de43 more cleanup about removing useless include 2020-10-02 15:50:46 +02:00
Jeff Young a25dfb2ac9 Stop setting modify from ClearAnnotation().
It's a side-effect, and as it turns out every current caller has
special-case code to reset it afterwards.
2020-09-06 11:26:39 +01:00
Jeff Young be15053745 Allow back-annotation of differing values and footprints.
Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)

Fixes https://gitlab.com/kicad/code/kicad/issues/5397
2020-09-04 15:21:56 +00:00
Jon Evans 30b402bc02 Don't set modify flag when deleting markers
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5418
2020-08-31 22:07:19 -04:00
Jon Evans 38a4e4ad5a Remove the last bits of the old netlist system 2020-08-30 16:30:04 -04:00
Seth Hillbrand c2847e00d8 eeschema: Fix crash when rescuing during update 2020-08-18 06:34:34 -07:00
Tomasz Wlostowski d937fadd6f Migrate RC_ITEM to use shared_ptr 2020-08-13 14:50:59 +02:00
Jeff Young f4ab14f32d Performance improvements for SchematicCleanup().
Fixes https://gitlab.com/kicad/code/kicad/issues/4563
2020-08-10 12:41:52 +01:00
Jeff Young c56599ab07 Allow ERC/DRC markers to be deleted without deleting exclusions.
Fixes https://gitlab.com/kicad/code/kicad/issues/4953
2020-08-02 22:45:48 +01:00
Jeff Young 7340c97ef9 Undo for schematic-wide operations.
Editing value/footprint fields of multi-unit components.
Find/Change.
Annotation.
Back annotation.

Fixes https://gitlab.com/kicad/code/kicad/issues/2122

Fixes https://gitlab.com/kicad/code/kicad/issues/4869

Fixes https://gitlab.com/kicad/code/kicad/issues/3933

Fixes https://gitlab.com/kicad/code/kicad/issues/4871

Fixes https://gitlab.com/kicad/code/kicad/issues/3899
2020-07-13 12:32:17 +01:00
Jeff Young c48f4272f3 Collapse a level out of the zoom settings.
The APP_SETTINGS_BASE now holds the list of zoom factors, and
the old legacy (screen-based) code has been removed.
2020-06-13 22:44:16 +01:00
Jeff Young f84406009b Push a couple of layers of indirection out of grid settings. 2020-06-13 11:35:56 +01:00
Jon Evans 2164501b06 Don't reparent symbol fields
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4540
2020-05-25 17:47:50 -04:00
Jon Evans 7c7b7f41da Move SCH_SCREEN project access to SCHEMATIC
SCH_SCREEN no longer needs to be a KIWAY_HOLDER
2020-05-20 22:27:48 -04:00
Jon Evans b6d7bc36d0 Ensure component bounding boxes are correct
This was causing junctions to not always be added on wire
segments that overlapped component pins, because the pin
might not be part of the component bounding box before
UpdateLocalLibSymbolLinks() is called.  When the bbox
was never updated, these symbols weren't collected by
the rtree query for objects overlapping a point.
2020-05-20 18:50:09 -04:00
Jon Evans fbc42a8cb5 Move schematic defaults to SCHEMATIC and add some missing settings entries 2020-05-20 00:03:23 -04:00
Jon Evans f4d7c323f5 Coverity fixes 2020-05-18 22:58:28 -04:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Jeff Young 301ac3461c Fix some more pen width issues from global removal.
Fixes https://gitlab.com/kicad/code/kicad/issues/4408
2020-05-12 15:20:17 +01:00
jean-pierre charras bc24d8e957 Fix typo and I18N string 2020-05-10 16:55:15 +02:00
Jon Evans c92181621e Use strong check for bus label when netlisting
Fixes #4318
2020-05-06 18:27:03 -04:00
Wayne Stambaugh aa9e74493f Eeschema: fix netlist creation crash when opening spice simulator. 2020-05-05 18:35:27 -04:00
Wayne Stambaugh a06fa22b8a Eeschema: remove rogue calls to SCH_SCREEN::UpdateSymbolLinks().
SCH_SCREEN::UpdateSymbolLinks() should only be called when working with
the legacy schematic file format.  Add schematic symbol library symbol
links should be set using SCH_COMPONENT::SetLibSymbol() which updates
the symbol link and pin map accordingly.

Change the schematic symbol LIB_ID edit dialog to properly use the new
SCH_COMPONENT::SetLibSymbol() function.
2020-05-05 12:52:17 -04:00
Wayne Stambaugh 169f63a6c0 Eeschema: make schematic sharing truly safe across all designs.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects.  It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic).  This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet.  This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references.  It also allows the root schematic from one project
to be uses as a sub-sheet in another project.

When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs.  This is done to ensure there
are no sheet path instance clashes between projects.  That being said,
there are no checks for this.  It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Jeff Young da1a89fc7e Allow users to control the order of sheets through sheet fields.
Fixes https://gitlab.com/kicad/code/kicad/issues/2394
2020-05-03 23:27:30 +01:00
Jeff Young 0370eff7ba Add sheet number processing to sheet fields.
Also fixes a bug where we were depending on the old deque stuff's
deterministic traversal, which isn't provided by the new RTree stuff.

Fixes https://gitlab.com/kicad/code/kicad/issues/2433
2020-05-03 20:56:32 +01:00