With hash character starting the reference value, schematic components
are considered as virtual and therefore netlist updater do not warn about
an unsigned footprint anymore. This approach is useful to handle logos,
frames or other virtual Eagle components.
Fixes: lp:1756281
* https://bugs.launchpad.net/kicad/+bug/1756281
- vias were always left selected, include vias in tracks filter - as in legacy
- make text filtering work
- cleanup drawings filtering code
- hide checkbox "Include items on invisible layers" because it does not work in GAL
ngSpice frequently ends up a simulation with an error:
"Error: ngspice.dll cannot recover and awaits to be detached"
The only way forward is to reload the shared library and
reinitialize ngSpice.
Fixes: lp:1753101
* https://bugs.launchpad.net/kicad/+bug/1753101
Clearing bClError flag in NumericEvaluator::parseOk() made the
expression look valid, even if the flag has been set for a previous
token. Now it is cleared before an expression is parsed and verified
after parser finishes.
Fixes: lp:1756995
* https://bugs.launchpad.net/kicad/+bug/1756995
If objects are at the clearance limit, they qualify as passing DRC.
Therefore, all comparison functions that indicate failure should be
strictly greater than or less than while all comparison functions that
indicate success (in the DRC) should be greater/equal or less/equal.
This also corrects a rounding error at the nm scale and handles
scaling zero-length and large segments correctly.
Fixes: lp:1756403
* https://bugs.launchpad.net/kicad/+bug/1756403
Fixes: lp:1593373
* https://bugs.launchpad.net/kicad/+bug/1593373
For some DRC checks, the location of the marker is not the location
of the first item in the resulting DRC_ITEM, so centering the screen
on PointA of the DRC_ITEM can be confusing.
DIALOG_SHIM stores the dialog position, so every time it is shown, it is
displayed in the same location. This caused problems on multidisplay
setups, as dialogs could show up off the screen if the original display
has been detached in the meantime, effectively making them inaccesible
to the user.
Fixes: lp:1756623
* https://bugs.launchpad.net/kicad/+bug/1756623
Add a check to see if the folder selected by the user contains a
project template meta data folder and use that folder instead of
assuming that it is a folder containing sub-folders with project
templates. The normal behavior is preserved when no meta data
folder is detected.
Fixes lp:1751465
https://bugs.launchpad.net/kicad/+bug/1751465