Seth Hillbrand 7b9c21e290 Not connected pins should not get connected
This prevents splitting wires/busses on the NC pin end.  It also keeps
NC pins out of the netlist.

Fixes https://gitlab.com/kicad/code/kicad/issues/6777
2020-12-17 11:56:42 -08:00
Jeff Young 10e68daa37 Fix some bugs in Change Symbol and Update Symbols.
In particular, there was a typo that kept library values from being
updated, and there was missing logic to fetch the various field names
from the library parts (and the change-to part).

Also implements some performance gains by desisting from copying
LIB_FIELDs around every time we want to look at them.

Fixes https://gitlab.com/kicad/code/kicad/issues/6733

Fixes https://gitlab.com/kicad/code/kicad/issues/6749
2020-12-15 16:12:17 +00:00
Jeff Young 55d0b79746 Make sure current sheet gets set when creating BOM.
Fixes https://gitlab.com/kicad/code/kicad/issues/6418
2020-11-18 17:32:40 +00:00
Jeff Young c1d1c12b41 Simplify message panel code.
We've had the colours turned off for two releases now without any
screaming or gnashing of teeth, so it's time to clean up the code.
2020-11-18 17:32:40 +00:00
Marek Roszko 16e3e59495 Split out arrayDim and MIRROR templates from macros.h
These were not macros
2020-11-17 20:21:04 -05:00
Jeff Young c89676e39d Require client to specify whether they want resolved values or not.
Fixes https://gitlab.com/kicad/code/kicad/issues/6408
2020-11-17 21:36:48 +00:00
Jeff Young 8c5c902fa3 Re-write IntersheetRefs on top of SCH_FIELDs and textVars.
1) Generalize SCH_ITEM owners (SCH_COMPONENT, SCH_SHEET, and now
SCH_GLOBALLABEL)
2) Generalize hypertext items
3) Use SCH_FIELD autoplace infrastructure for placing intersheet
references
4) Use textVar infrastructure for buildin intersheet references.

As an important side-effect this also fixes the undo issues with
intersheet refs.
2020-11-17 16:05:49 +00:00
Jeff Young d616d5ad1f Naming conventions. 2020-11-17 16:05:49 +00:00
Jeff Young b227d2b910 More component -> symbol. 2020-11-15 20:23:15 +00:00
Jeff Young 7bd31d5237 Naming conventions. 2020-11-14 18:26:03 +00:00
Jeff Young 8bae52d1c3 Correct naming conventions. 2020-11-14 14:29:11 +00:00
Jeff Young f0d0e17aab Prepare for MODULE -> FOOTPRINT. 2020-11-13 15:16:24 +00:00
Jeff Young bfd8a62852 Formatting and naming conventions. 2020-11-07 18:50:30 +00:00
Marek Roszko a785f70ea1 msgpanel is a widget, shove it to the right folder. 2020-10-25 20:01:12 -04:00
Seth Hillbrand 661e85d705 Standardize "Key words" to "Keywords" 2020-10-20 13:18:48 -07:00
Jeff Young 8f67557a65 Separate display and canonical names in Edit Symbol Fields.
Fixes https://gitlab.com/kicad/code/kicad/issues/6066
2020-10-19 23:58:07 +01:00
Marek Roszko 12d21e34e2 Remove trigo.h from eda_text.h 2020-10-13 23:37:48 -04:00
jean-pierre charras 7865d8de43 more cleanup about removing useless include 2020-10-02 15:50:46 +02:00
Jeff Young 64fa400b19 Ease translation a bit.
Also improves the SNR and consistency of the menu item text.  For
instance, a position is rarely useful, while relative sizes can be.

Also removes some unnecessary repitition, such as "Graphic Rectangle"
when "Rectangle" communicates the necessary information.
2020-09-19 18:49:06 +01:00
Wayne Stambaugh d45c11b4b5 Exclude from bill of materials and board netlist to library symbols.
ADDED: Support for exclude from bill of materials and board netlist to
library symbols.

Fixes https://gitlab.com/kicad/code/kicad/issues/4915
2020-09-09 09:03:37 -04:00
Seth Hillbrand 02a5d47de9 Avoid passing references in EESchema
This returns the connection list by value.  This allows easier Python
use

Also renames m_End() to GetEnd()
2020-09-08 06:29:27 -07:00
Jeff Young 054b5aa475 Fix copy-pasta. 2020-09-08 11:02:09 +01:00
Jeff Young 7b05e456cc Bug fixes for multiple symbol instances in complex hierarchies
1) use SCH_COMPONENT::GetRef(), GetValue() and GetFootprint() when
instance-specific info is needed
2) update UpdateAllScreenReferences() to handle value and footprint.
3) BACKANNO is CvPcb's handler, not back annotation's handler.  Which
means it needs GUI behaviour, not back annotation behaviour.

Fixes https://gitlab.com/kicad/code/kicad/issues/5520
2020-09-06 13:57:14 +01:00
Jeff Young a25dfb2ac9 Stop setting modify from ClearAnnotation().
It's a side-effect, and as it turns out every current caller has
special-case code to reset it afterwards.
2020-09-06 11:26:39 +01:00
Jeff Young be15053745 Allow back-annotation of differing values and footprints.
Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)

Fixes https://gitlab.com/kicad/code/kicad/issues/5397
2020-09-04 15:21:56 +00:00
Jon Evans 38a4e4ad5a Remove the last bits of the old netlist system 2020-08-30 16:30:04 -04:00
Jeff Young 97c34e2516 ADDED alternate pin definitions and assignments.
Fixes https://gitlab.com/kicad/code/kicad/issues/2002
2020-08-21 18:29:36 +01:00
PJM f58221ca98 Add 'GetBoundingBox' that optionally only calcs w visible fields
Cross-probing from Pcbnew to Eeschema revealed that EEschema was
including all fields, visible or not, when calculating the bounding
box of the probed componentt.  This caused problems with long strings
such as URLs that were not set as visible.  The cross-probing code
tries to minimize 'Zoom to Fit' operations when it's not necessary,
and the overly large bbox values often resulted in zooms not being
performed and components displayed very small.

This code adds a version of 'GetBoundingBox' that takes a boolean
to tell it to include invisble fields or not.

Addresses issue: https://gitlab.com/kicad/code/kicad/-/issues/5149
2020-08-15 22:15:30 +00:00
Jeff Young 2b0b7a5153 Clear pin net-name-driving cache when changing annotation.
Also update connectivity after clear annotation, annotate or back
annotate.

Also update status bar for highlighted nets.

Fixes https://gitlab.com/kicad/code/kicad/issues/5170
2020-08-14 12:41:20 +01:00
Jeff Young e325d2e18f Allow Net Inspector to create, rename and delete nets.
ADDED: create/edit/delete nets in PCBnew Net Inspector
ADDED: update from PCB now allows updating of changed nets

Fixes https://gitlab.com/kicad/code/kicad/issues/1996
2020-07-11 21:19:49 +01:00
Jeff Young 32c3ea4edd Flags cleanup.
Remove extraneous use of FLAG0 from tracks cleaner (it was checked but
never set).

Fix issue in expand connections where two parts of it couldn't agree
on the same flag (BUSY vs SKIP_STRUCT), and where the second part was
clearing the flag instead of setting it.

Remove obsolete HIGHLIGHT infrastructure (we now use selection).

Remove extraneous use of BUSY flag in several places (it was never
set).
2020-06-27 17:53:04 +01:00
Wayne Stambaugh 037898f6fb Eeschema: add support for excluding symbols from board.
ADDED: Support for excluding symbols from board during.  This allows for
creating bill of materials only symbols.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/2522
2020-06-10 10:57:28 -04:00
Wayne Stambaugh 77a59fb5d3 Eeschema: add support for excluding symbols from bill of materials.
This provides a method to add symbols that represent footprints on the
board that do not have an associate component such as mounting holes,
fiducials, logos, etc that should be excluded from the bill of materials.
It also prevents those footprints from being removed from the board
accidentally when updating the board from the schematic.

ADDED: Support to exclude schematic symbols from bill of materials
export.
2020-06-03 08:55:13 -04:00
Wayne Stambaugh 52078a4b1b Allow setting mandatory derived symbol field properties.
CHANGED: All mandatory fields in derived symbols can be edited.  This
not only includes the field value but also all text properties.

Kill the dual datasheet variable storage which caused many datasheet
bugs over the years.  The datasheet is now always stored in the data
sheet field.
2020-06-02 14:21:11 +00:00
Wayne Stambaugh b83d64fc0d Eeschema: remove superfluous updating of SCH_COMPONENT pins.
Every time SCH_COMPONENT::GetDrawItem() was called, the schematic symbol
pin table was updated.  Under certain conditions, this happens inside
loops so the amount of time spent rebuilding the pin table can add up.
2020-05-28 18:32:28 -04:00
Jeff Young 8d92a95cb8 Fix a couple of issues with text var autocomplete.
Fixes https://gitlab.com/kicad/code/kicad/issues/4190
2020-05-28 20:00:21 +01:00
Jeff Young 8b084c373e Autocomplete for text variables.
Fixes https://gitlab.com/kicad/code/kicad/issues/4190
2020-05-27 23:29:51 +01:00
jean-pierre charras 14f5ef4078 Eeschema: ensure component edit flags are cleared after loading a schematic file.
Fixes #4515
https://gitlab.com/kicad/code/kicad/issues/4515
2020-05-22 20:25:43 +02:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Jeff Young ae102c7411 Remove bogus assert. Also fix const leak.
Fixes https://gitlab.com/kicad/code/kicad/issues/4367
2020-05-08 23:30:33 +01:00
Wayne Stambaugh bc0fc0bb3a Eeschema: fix broken net list items in schematic symbol object.
Fixes https://gitlab.com/kicad/code/kicad/issues/4358
2020-05-07 16:28:59 -04:00
Wayne Stambaugh aa9e74493f Eeschema: fix netlist creation crash when opening spice simulator. 2020-05-05 18:35:27 -04:00
Wayne Stambaugh 590a101a88 Eeschema: fix update schematic symbol library link bugs. 2020-05-05 18:06:43 -04:00
Wayne Stambaugh 00716e362a Eeschema: simplify updating symbol alternate body style.
Move updating the pin maps from external code to the SCH_COMPONENT object
when changing the symbol body style (DeMorgan).  This is a vein attempt
to make the SCH_COMPONENT object self contained so we don't have to depend
on the caller needing to figure out how to keep internal objects synced.
2020-05-05 16:42:59 -04:00
Wayne Stambaugh 5cf474e1c8 Eeschema: fix bugs in symbol edit properties dialog.
Use flattened (root) library symbols to prevent broken library symbols
in schematic files.

Remove the edited symbol from screen before making changes to the symbol
to prevent potential orphaned symbol libraries being saved in schematic
file.

Add some defensive programming to let developers know that an invalid
library symbol link was used when calling SCH_COMPONENT::SetLibSymbol().
2020-05-05 10:56:23 -04:00
Wayne Stambaugh a8407fba4c Fix schematic field index bug in s-expression file format plugin. 2020-05-04 12:40:03 +00:00
Wayne Stambaugh 169f63a6c0 Eeschema: make schematic sharing truly safe across all designs.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects.  It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic).  This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet.  This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references.  It also allows the root schematic from one project
to be uses as a sub-sheet in another project.

When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs.  This is done to ensure there
are no sheet path instance clashes between projects.  That being said,
there are no checks for this.  It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Jon Evans 1204b9cbef Use cached pins in SCH_COMPONENT::GetEndPoints() 2020-04-30 19:53:25 +00:00
Jeff Young 1535c83b88 Lay some groundwork for adding distances to DRC errors.
modified:   eeschema/lib_rectangle.cpp
2020-04-24 14:46:22 +01:00