Do not add cache library from another project to old library list. This
is wrong and can cause all kinds of symbol library linking issues. It's
better to force the user to fix broken symbol library links than the false
security of using multiple cache libraries.
Use correct paths when appending schematic outside of the current project
path when hierarchical sheets are appended. If the path can be relative,
give the user the option to use either relative or absolute paths.
Do not change symbol library names in schematics appended from a source
outside the current project. This will almost ensure the symbol library
links will be broken in the source project.
When the appended schematic is from another project, attempt to check all
of the possible combinations of symbol library table importing that could
cause broken symbol library links and give the user the option of canceling
the append operation or live with the possibility that there may be broken
symbol library links.
When the append schematic is in the current project path but not part of
the schematic, check to see if there are any library nicknames that do
no exist in the project symbol library table and give the user a chance
to cancel the append process.
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
When loading a part in libedit, also transfer certain screen
settings to the incoming SCH_SCREEN, from the current
SCH_SCREEN.
Currently, the grid settings are transferred, but this could
also do other settings if needed.
Also remove some duplicate commentary and mention why the
grid is set in a SCH_SCREEN even though the BASE_SCREEN ctor
sets the same default.
Fixes: lp:1815108
* https://bugs.launchpad.net/kicad/+bug/1815108
The standard DIM() macro was not typesafe as it happily deferred errors
to runtime that can be caught at compile time. Replacing it with a
generic C++11 constexpr allows for typecasting, comparison and compile
time error checking.
When expanding the drag item to allow corners, we accidentally picked up
other items in the list. This limits the items that can be dragged to
only those that are explicitly in the draggable list.
A side effect of this commit is that when converting from move to drag
(with tab), items not in the draggable list will be left in place.
Fixes: lp:1787966
* https://bugs.launchpad.net/kicad/+bug/1787966
Previously, when creating a new instance of a sheet, the full set of references
was cleared.
Moreover, if this sheet has sub-sheets, the annotation was incorrectly handled
Now only (and all) new sheet path(s) created have a reference cleared, as expected.
(new sheet paths can be more than one, if the new instance of the sheet has sub-sheets)
Fixes: lp:1789048
https://bugs.launchpad.net/kicad/+bug/1789048
It was only a overzealous (in this case) assert, with no issue.
The fix avoid calling DeleteAll() when there is nothing to delete.
Fixes: lp:1787810
https://bugs.launchpad.net/kicad/+bug/1787810
Allows buses to acquire junctions based on their connections. Buses
can only have junctions with other buses. Also allows buses to be
draggable junctions for collections
This adjusts the selection addition criteria for
blocks to allow items such as labels to connect to
lines not at the endpoints. It also uses the same
logic to correctly gather bus-wire, bus-bus entries.
Fixes: lp:1738941
* https://bugs.launchpad.net/kicad/+bug/1738941
Pins are weak_ptrs to the library, so they require a lock() before
accessing. This imposes a performance hit on fast loops that access
the pin list repeatedly. This patch caches the pin position locally
for each component, updating only when needed.
Fixes: lp:1737363
* https://bugs.launchpad.net/kicad/+bug/1737363
Fixes the connection display and dragging behavior of wires,
busses and their entries.
The implemented drag logic is:
-busses and bus-bus entries drag each other when connected at endpoints
-wires and wire-bus entries drag each other when connected at endpoints
-entries do not drag wires or busses when connected to wire middles
-wire-bus entries do not drag busses
The implemented connection logic is:
-bus-bus entries connect busses to busses but not wires
-wire-bus entries connect wires to busses but not wire to wires or
busses to busses
BreakSegment now breaks a known segment and BreakSegments
breaks all segments. This allows functions to break a
segment without needing to iterate through the whole list.