When Validate() find an out of limits user value, it displays the limits.
However, the displayed limit value was incorrectly converter to internal units,
and strange values were displayed.
GTK only calculates new widths once the tree is displayed,
so calling Refresh after updating the tree but before display
will return a column width of 0. Instead, use saved column
widths if an invalid width was returned.
Fixes https://gitlab.com/kicad/code/kicad/issues/4837
Adds a possibility to replace properties inherited from base types with
a more specific ones. For example, such properties may have:
- different meaning which should be reflected in property name
(e.g. TRACK::{G,S}etWidth() sets actual track width, but
VIA::{G,S}etWidth() modifies the diameter)
- different set of possible values (e.g. BOARD_CONNECTED_ITEM::SetLayer()
should accept any copper layer, but MODULE::SetLayer() works only with
F.Cu and B.Cu)
Introduces classes:
- INSPECTED: base class for types taking advantage of
generic properties system.
- PROPERTY*: meta-data storing information about properties
- PROPERTY_MANAGER: singleton class to get properties data
- New public static function OPENGL_GAL::CheckFeatures() gets called in EDA_DRAW_PANEL_GAL::SwitchBackend() before switching to OPENGL_GAL
- Moved all OpenGL feature checks from OPENGL_GAL constructor to OPENGL_GAL::init()
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4714
As long as the arc angle stays below <60°, it will automatically choose between
clockwise and counter clockwise. This allows the user to choose the direction
with a simple mouse movement.
Swap syncs can limit the redraw rate as the screen waits for previously
issued syncs. Setting this to -1 allows for adaptive swapping
(resorting to unsynced if it falls behind) if it is supported by the
card but will fall back to unsynced (0) if the adaptive is not
supported.
Fixes https://gitlab.com/kicad/code/kicad/issues/4226
- Fix file extension for new project
- Fixes for exceptions on MSW
- Fix some ASAN issues
- Allow SETTINGS_MANAGER to run headless
- Don't flag schematic as modified after schematic setup is closed
- Don't automatically unload projects when LoadProject is called
- Don't unload project if it's the same as the current one
- Make sure to properly init/de-init template field names
Per discussion on the developers list, this old system
no longer provides much value and is seen as annoying
by many users. The new save logic should prevent any
cases of file corruption on save, which was a major
reason for the backup file system existing.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/2012
Various architecture upgrades to support this.
Creating a BOARD now requires a valid PROJECT, which caused
some (mostly transparent) changes to the Python API internals.
ADDED: Project local settings file
CHANGED: Board design settings are no longer stored in PCB file
CHANGED: Net classes are no longer stored in PCB file
CHANGED: Importing board settings now reads boards, not just projects
Fixes https://gitlab.com/kicad/code/kicad/-/issues/2578
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4070