3dviewer: back to double (from float) in class S3D_MASTER for 3 members (m_MatScale, m_MatRotation, m_MatPosition) which are used in dialogs and r/w file functions, which expect double.
Using float create minor but unwanted issues in r/w file functions.
S3D_MATERIAL: enable all color options: if a 3d shape has bad color parameters, the shape must be modified, not the 3d rendering.
The rendering now matches what we see in other vrml viewer like FreeCAD.
Some minor coding style fixes.
- Removed spurious int casts (these are truncated anyway and will break
doubles)
- Applied the Distance, GetLineLength, EuclideanNorm, DEG2RAD, RAD2DEG
ArcTangente and NORMALIZE* functions where possible
- ArcTangente now returns double and handles the 0,0 case like atan2, so
it's no longer necessary to check for it before calling
- Small functions in trigo moved as inline
* serious code cleanup (remove duplicate code)
* shows (option in 3D preference menu) the copper items (tracks, zones...) in 3D, using 35 microns copper thickness.
However, because there are a lot more3D data to show (roughly 4 times more), this is slower.
All: press ctrl+shift key when moving the mouse allows the graphic cursor to be moved outside the grid.
(useful to place graphic objects, texts in any position, regardless the current grid)
* Replace C malloc() and free() functions with C++ new and delete
operators or the appropriate STL container.
* Add option to end mouse capture function to skip executing the end
mouse capture callback.
* Lots of coding policy and Doxygen comment goodness.
* All header files used to create the PCB common library now compile as
stand alone code. This prevents the need to define them in a specific
order to make source code compile properly. It should also now be
possible to relocate the source code to build the common PCB library
to a separate folder.
inches and mm, the industry is crazy enough to force us with mixed
design. For example I routinely use imperial units for track size and
clearance, but drilling is strictly a metric issue...
So I added a little parser to recognize a suffix specification in the
unit text boxes... so you can put in things like:
1in (1 inch)
1" (idem)
25th (25 thou)
25mi (25 mils, the same)
6mm (6 mm, obviously)
The rules are: spaces between the number and the unit are accepted, only
the first two letters are significant.
As a bonus, it also recognize the period (.) as a decimal point
substituting it with the correct locale character (there was a wishlist
for it, IIRC). Most useful for number pad fans :D
* Complete comment translation for all EESchema source files.
* Complete comment translation for all 3D viewer source files.
* Rename class class_hierarchical_PIN_sheet to SCH_SHEET_PIN.
* Rename class DrawSheetStruct to SCH_SHEET.
* Tool tip capitalization fixes.
* Uncrustify and spell check comments and strings in all modified source