Using the infobar for errors doesn't steal focus from the cpvcb
main window when they are displayed like a dialog does, so it
allows for them to be visible without interrupting navigation
in the listboxes.
CHANGED: Cvpcb fpviewer and the pcbnew fpviewer no longer have an options dialog
ADDED: Add a side toolbar to the pcbnew footprint viewer (and the measure tool)
This also cleans up some of the settings structs in the viewers, since
it was somewhat confusing before.
Fixes https://gitlab.com/kicad/code/kicad/issues/2205
* Consolidate the measure tool into one tool (this gives cvpcb
unit changing and snapping capabilities in its measure tool)
* Transition cvpcb to use actions for the sketch modes
* Replumb how magnetic items settings are stored and used
* Push all sizing operations into EDA_BASE_FRAME
* Save the unmaximized window size when maximizing
so that we can then save it in the config if the
window is maximized. Otherwise the config ends up
with the maximized size saved, and weird behavior
occurs when unmaximizing on the next opening.
CHANGED: Settings are now stored in versioned sub-directories
ADDED: First-run dialog for migrating settings from a previous version
CHANGED: Settings are now stored as JSON files instead of wxConfig-style INI files
CHANGED: Color settings are now all stored in a separate settings file
CHANGED: The symbol editor and footprint editor now have their own settings files
CHANGED: Color settings are no longer exposed through BOARD object
CHANGED: Page layout editor now uses Eeschema's color scheme
Settings are now managed through a central SETTINGS_MANAGER held by PGM_BASE.
Existing settings will be migrated from the wxConfig format on first run of each application.
Per-application settings are now stored in one class for each application.
* Make the grid display settings separate from the board object
* Ensure that the grid is initialized on creation in all the frames
Fixes: lp:1843169
* https://bugs.launchpad.net/kicad/+bug/1843169
The pointer passing for display options is deprecated. This removes the
excess casting as the EDA_FRAME didn't need the base call with no value.
All requests for display options are now returned const and are updated
with a Set() routine after modification.
In Gerbview, this resolves an issue where the display options were not
stored because it was receiving the NULL from EDA_FRAME.
The iterators are not removal safe outside of the class. We provide a
safety clear function that frees the associated memory.
Fixes: lp:1831465
* https://bugs.launchpad.net/kicad/+bug/1831465
It was due to the fact the frame size was set before the draw canvas panel was created,
thus creating incorrect size of the other panel (the message panel)
Fixes: lp:1831389
https://bugs.launchpad.net/kicad/+bug/1831389
It was confusing that the primary frames registered their tools
differently than the other frames. In addition, since the other
frames also added their own tools, foo_actions::RegisterAllTools()
didn't really register all tool but rather those used by the
principal frame (PCB_EDIT_FRAME, SCH_EDIT_FRAME, etc.)
wxChoice centers the selection on GTK. So when switching from a
mid-list item to an item at the top, the list is always cut off for
choice lists located on the top toolbar. Using a combobox provides a
drop-down that allows easier access to all elements in the box.
Fixes: lp:1808569
* https://bugs.launchpad.net/kicad/+bug/1808569
Add Display Settings to Footprint Browser.
Make each of them OpenGL on OSX and Cairo on other platforms.
Allow auto-zoom to be turned off and save last zoom setting.
Make ordering of tools in htoolbar consistent.
Standardize grid and zoom drop-downs.
Fixes: lp:1791667
* https://bugs.launchpad.net/kicad/+bug/1791667