Note that since the markup might exist for other reasons, it has
to be turned on with a preference setting. (It goes through a set
of bitflags so the same architecture can be used for other markup
structures that we might want to support in the future.)
Note also that this is more about engineering nomenclature than
visual formatting. In that respect it's more similar to overbar
than italic or bold.
5.0 doesn't set the GAL's line width. It gets away with this since
it's using the same GAL to measure as to set up the drawing, so
the width happens to be set correctly for other reasons. 5.1 uses
a separate GAL and so isn't so lucky.
eeschema now supports arbitrary colors for all object types, and
pcbnew does in GAL canvas. When switching from GAL to legacy canvas,
pcbnew will convert colors to the nearest legacy color.
Make all EDA_TEXT data private and rename accessors to avoid function
name collisions in derived classes.
Overload EDA_TEXT's SetTextAngle() and SetEffects() in TEXTE_PCB.
Add support for preserving Reference text position, size, orientation
during a netlist import into a BOARD, as well as the one off footprint
update dialog.
It should help if (or when) the internal angle unit used in kicad will be changed from 0.1 degree (a relic of code written for PCs without fpu) to degree ( a more natural unit).
- Removed the friends MODULE and FOOTPRINT_EDIT_FRAME from TEXTE_MODULE
(as in the @todo comment)
- Refactored the Rotate/Flip/Mirror for text in modules into the
TEXTE_MODULE class itself (members RotateWithModule, FlipWithModule,
MirrorWithModule)
- New behaviour in coloring text on screen: reference and value still
take the color from the MOD_TEXT_FR_VISIBLE and MOD_TEXT_BK_VISIBLE
visibles; other text takes the color of the layer containing it
(except when hidden, obviously) but still get its visibility
controlled by those visibles (probably the most intuitive and useful
behaviour)
- Still need to decide: should text on a layer be hidden when the layer
is? Probably yes (still to be implemented);
- Some comment fixed and many cast converted to static_cast
Eagle plugin: filter and replace not allowed chars in FPID(-':' and '/') by _ or -, if they are used in Eagle footprint names (otherwise, boards converted and saved under kicad_pcb format are not readable by Pcbnew).
Fix issues created by this patch.
Note, this fix slightly changes the vertical position of these texts.
This is not really a problem in eeschema, but in pcbnew this is perhaps more annoying, if the verical multiline text is critical.
Fix a very minor issue for vertical justification of single line texts in dxf import.
File "rules" has instructional text as comments near top.
2) Convert all text files in repo to LF line ending form.
Any checkout done with "rules" in play will convert the working
tree to native line ending, while keeping repo as LF line ending.
* Complete encapsulation of the MODULE class.
* Complete encapsulation of the EDA_TEXT class.
* Encapsulate most of the ZONE_CONTAINER class.
* Add pcbcommon library as a dependency for reSWIGging the scripting
support. This should cover most dependency cases.
* Encapsulate most of the MODULE class.
* Start encapsulating the DIMENSION class.
* Lay some groundwork for EDA_TEXT encapsulation.
* Move cleverly hidden MODULE functions into class_module.cpp.
* Use std::swap to exchange TEXTE_PCB values for undo/redo.
* Remove unused members from MODULE class.
* The usual coding policy and documentation fixes.