This was leaking windows headers and partial wx headers to 1084 compilation units......
This also means math/util.h is leaking to 1084 compilation units which seems a bit high too.
In CADSTAR pins are single points. We can replicate the original look
of the schematic in most cases by searching the symbol for straight
segments that are coincident with the pin and use those to calculate
a suitable pin length and angle.
Create a new LIB_PART for scaled symbols. These will be then embedded
into the schematic file. However when "update from library" is done,
it will revert to the unscaled symbol.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/8494
Differentiates better between the EDA_ITEM IsModified(), referring to
items themselves changing and the EDA_SCREEN IsContentModified(),
referring to whether we have made any unsaved changes.
Use justification instead of orientation relative to the anchor point when
describing text direction and alignment. This seems to be the preferred
method by most users so hopefully this will eliminate some confusion.
Fix a bug in the s-expression schematic parser that failed to take into
account how graphical text alignment is defined for graphic text objects
compared to label text objects.
Fixes https://gitlab.com/kicad/code/kicad/issues/6489
Save sheet and symbol instance information to the clipboard on copy
Load sheet and symbol instance information from the clipboard on paste
and renumber page numbers after loading.
Correctly handle pasting in a multiple hierarchy by ensuring symbol and
sheet instances are updated for all instances of the destination sheet.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/8207
Avoid code duplication by moving all common code to a new function
SCH_SEXPR_PLUGIN::saveInstances
Also fixes a bug that was resulting in footprint and value information
not being saved for subsheets that were root sheets in a different
project.
This change is a bit more invasive than the description above would
suggest. UUIDs have been added to all schematics. For now, it's only
useful to the root schematic so that the UUID in the project file does
not change every time the project file is save. In the future, it may
be useful to store and check the schematic UUIDs against the one's saved
in the project file.
Fixes https://gitlab.com/kicad/code/kicad/issues/7763
If a field name is already in use, try to rename the new field name
(adding the suffix "_1" or "_2" or ... )
This is especially critical when a non mandatory field has the same name as
a mandatory field (was crashing before)
Fixes#8081https://gitlab.com/kicad/code/kicad/issues/8081
The previous assumption was that a part definition would always hold
the information about the symbol. However some designs have symbol
instances that refer to a different symbol definition than that
specified in the part.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7808
Always add a label at bus terminals to ensure connectivity. The original
design might already have a bus terminal with a given location.
If the original design does not have a label, just make it very small
to keep connectivity but make the design look visually similar to
the original.