david-beinder
c34f45f646
Split global label size expansion from TextOffset setting
...
Global label expansion ratio default is now 37.5%
Wire text offset default is now 15%
2021-08-02 16:40:36 +00:00
Wayne Stambaugh
71c183d7bb
Rename LIB_PART to LIB_SYMBOL.
2021-06-14 07:11:17 -04:00
Jeff Young
faf9cca938
Fix many cases of old mils flag getting interpreted as allowEval flag.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/7883
2021-03-12 15:15:50 +00:00
Franck Jullien
c16199c3f9
eeschema: add a setting to allow intersheets to not list their own page
...
Also disable inter-sheet options when "Show inter-sheet references" is
not checked.
2021-03-08 20:40:37 +00:00
Jeff Young
ff7742c6b8
File naming and include cleanup.
2021-01-28 11:35:18 +00:00
Jeff Young
8c5c902fa3
Re-write IntersheetRefs on top of SCH_FIELDs and textVars.
...
1) Generalize SCH_ITEM owners (SCH_COMPONENT, SCH_SHEET, and now
SCH_GLOBALLABEL)
2) Generalize hypertext items
3) Use SCH_FIELD autoplace infrastructure for placing intersheet
references
4) Use textVar infrastructure for buildin intersheet references.
As an important side-effect this also fixes the undo issues with
intersheet refs.
2020-11-17 16:05:49 +00:00
Ian McInerney
1db15052b0
Remove unused schematic settings filed
...
It was never written to the file and never used.
2020-11-15 21:30:50 +00:00
Wayne Stambaugh
4ea3914d4e
Coverity fixes.
...
CIDs: 312996, 305508, 305509, 305510, 312992, 312997, 312994, 312995,
312968, and 306650.
2020-11-10 08:50:16 -05:00
PJM
43176a5b29
Eeschema: Add Schematic Setup GUI to set junction dot size from list
...
CHANGED: In Schematic Setup->General->Formatting->Connections, added
pulldown for "Junction dot size" with values none, smallest, small
default, large, largest" Added support in "sch_painter.cpp" to not
paint junction when they have a diameter of "1" which is what "none"
sets as the diameter.
2020-11-04 01:49:41 +00:00
Mikolaj Wielgus
d14761bee6
Fix inches being sometimes used instead of mils
2020-10-03 20:06:56 +00:00
Mikolaj Wielgus
400c15b8eb
Add mils to units, remove useMils variables
2020-10-03 20:06:56 +00:00
jean-pierre charras
bda275de46
more cleanup about removing useless include
2020-10-03 11:48:16 +02:00
Franck Jullien
2fc49045d1
ADDED: eeschema: Add intersheets references function
...
Add a new function to place intersheets references next to
global labels.
2020-10-01 20:39:32 +00:00
PJM
1eb423830e
Eeschema: Remove wire and bus formatting GUI elements
...
CHANGED: Remove wire and bus formatting GUI elements from "Schematic
Setup" dialog panel. Wire thickness is handled by netclasses now
and this was a leftover from before that change.
Fixes https://gitlab.com/kicad/code/kicad/issues/5815
2020-10-01 00:20:31 +00:00
Jeff Young
b74e125264
Read/write schematic netclass properties.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/4990
2020-07-27 23:10:46 +01:00
Jon Evans
12b4a55ae8
Port Eeschema to new project settings
...
DRC/ERC error serialization changed to use explicit tokens
Old stored severities and ignored errors are discarded
2020-07-02 22:08:54 -04:00
Jeff Young
d61b6f965e
Flatten some settings and remove some more globals.
2020-05-23 16:50:33 +01:00
Jon Evans
fbc42a8cb5
Move schematic defaults to SCHEMATIC and add some missing settings entries
2020-05-20 00:03:23 -04:00
Jeff Young
c155d80213
User configurability of pin electrical symbol size.
...
Also fixes a bug where a bunch of eeschema settings weren't getting
loaded because it looked like they were larger than the max value
(which wasn't being scaled from mils to internal units).
Fixes https://gitlab.com/kicad/code/kicad/issues/2089
2020-05-04 00:56:32 +01:00
Jeff Young
2b6089240a
Change super/subscript syntax to ^{foo} and _{foo}.
2020-04-18 21:04:41 +01:00
Jeff Young
9c8941e040
Remove a bunch of globals.
2020-04-16 17:34:46 +01:00
Jeff Young
591428b0d9
Remove some problematic global variables.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/4121
2020-04-05 16:17:04 +01:00
Jeff Young
40b2eabfc1
Add a user-defined ratio for text offset from wire/bus.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/2392
2020-03-17 12:50:31 +00:00
Jeff Young
085d80e3f3
Remove duplicated settings from preferences.
...
These have now moved to project-specific settings.
2020-03-13 17:28:53 +00:00
Jeff Young
437f888c25
Schematic Setup dialog.
...
Includes:
- moving some of the project settings from the Preferences dialog
- ERC severites
- project-specific field-name templates
Fixes https://gitlab.com/kicad/code/kicad/issues/2145
2020-03-10 18:54:17 +00:00