The new code was added to handle saving imported worksheets,
but it is possible to specify relative paths to worksheets
not only to the project folder but also to the global
templates directories.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13834
Pass 'false' as aStartAtCurrent to ReannotateByOptions(). Causes Pasing() symbols to start at the first available refdes after the currently
configured annotate start number, m_annotateStartNum.
Fixes#13342
Don't use the value field when adding Eagle part attributes to a symbol.
This issue was cause by using a mandatory symbol field ID instead of
using the next available field ID when adding new fields to as symbol.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13468
Remove some useless spacers, and do not force some widgets to have a to
large size (by removing empty areas).
Work in progress: one panel is still too big.
The ngspice manual does not indicate that there is any default
model type. This change ensures we get a `level=xy` written out to the
.model line when we select a HiSIM_HV model.
- generate .model lines in spice netlist for all device types that need
one
- add "level=<n>" to .model line for non-default model levels. This is
necessary to allow more sophisticated models to be used, and some
devices *always* need a level specified (e.g. JFETs)
- add "version=<n>" to .model line for models that have multiple
versions available (AFAIK only affects HiSIM_HV MOSFET models)
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/13775
Only update value and footprint fields from instance data if it's not
empty. These fields were not always stored in the instance data so
loading them from instance data that does not contain them will clear
the fields.
https://gitlab.com/kicad/code/kicad/-/issues/13735
Rather than update library symbols one at a time, queue them up by
schematic symbol to prevent multiple updates to the same symbol in
complex hierarchies. This also removes all of the library symbols
first which will clear out all of the library symbol variants that
were created by modifying library symbols in place and/or changes to
the symbol in the library.
Don't add new variant library symbol if an equivalent variant already
exists in the schematic local cache. This prevents duplicate library
symbols from being added to the local cache when the first variant in
the cache does not match that of the symbol being added.
The lib table returns a properly sorted list of libraries already, which
we just iterate through. A std::set is a sorted collection, but uses a
different sorting function than the lib table, so appending to a
std::set breaks the initial sorting that was done already.
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/13530
SCH_EDIT_FRAME::RecalculateConnections() calls SchematicCleanup and then
resets the connectivity graph and recalculates it. OnModify() also
calls RecalculateConnections(). For long calculation schematics, this
can impact usability
We don't need two functions to get driver names. The map should be
mutable to allow updates when needed. C++17 gives some extra syntactic
sugar for map manipulation
Fixes#10926
Contains the following changes:
- Adds a new ERC_SCH_PIN_CONTEXT class which is used to provide deterministic
comparison between items causing ERC violations (e.g. pins) when associated
with a SCH_SHEET_PATH context.
- Adds association of SCH_SHEET_PATHs for ERC_ITEMs and the sub-schematic items
which caused an ERC violation. This allows correct display of markers on the
sheets of interest only, and allows correct naming resolution and cross-probing
from the ERC dialog.
- Adds a new ERC_TREE_MODEL class, derived from RC_TREE_MODEL, which correctly
resolves component references across heirarchical sheets using the associated
SCH_SHEET_PATHs. This allows sheet-specific component references to be displayed
correctly in the ERC results tree.
- Updates SCH_MARKER to only draw sheet-specific markers on the sheet causing
an ERC violation.
- Increments the schematic file version.
- When loading a schematic with legacy ERC exclusions, discards those of type
ERCE_PIN_TO_PIN_WARNING, ERCE_PIN_TO_PIN_ERROR, ERCE_HIERACHICAL_LABEL, and
ERCE_DIFFERENT_UNIT_NET as there is no safe way to automatically infer the
information which is now stored with these exclusions (sheet paths for error
location and related items). Requiring users to (once) re-add exclusions is
preferable to silently incorrectly matching new ERC issues to legacy exclusions.
The PEGTL parser used by KiCad for SPICE models only handles ASCII
characters. Despite the docs stating that you can, in theory, parse a
UTF-8 character by reading the base string, in pratice this does not
work as the UTF-8 string is represented by unsigned chars and the PEGTL
string is based on signed char.
To work around this, we need to convert micro and mu to the ASCII 'u'
equivalent
Fixes https://gitlab.com/kicad/code/kicad/issues/13642
When the designer asks to reset annotations, we reset all annotations
including power symbols. This may create additional churn in the files
but only when requested and is useful to fix schematic errors
Fixes https://gitlab.com/kicad/code/kicad/issues/13138
LIB_TEXT is not all aligned to the center, so place the proper flags
when calling Plot. This requires handling alignment offsets properly
when rotated as well
And add tests to see if the file can be saved
Fix also an issue in sch_editor_control.cpp: The page setup dlg must generate changes
only if the OK button is clicked.
Fixes#13599https://gitlab.com/kicad/code/kicad/issues/13599