Commit Graph

88 Commits

Author SHA1 Message Date
Mikolaj Wielgus 6fad25f8ed Allow mapping sim model pins to arbitrary string symbol pin numbers
This change removes the incorrect assumption that symbol pin numbers are
integers and are the same as indexes in the vector storing the symbol
pins.

"~" is now used to denote a floating sim model pin.
2022-08-22 08:13:26 +02:00
Jeff Young 4f0136db3b Attempt to fix std::initializer_list lifetime issue. 2022-08-21 20:54:41 +01:00
Jeff Young aa2ad3b44c Move KICAD_T[] to std::initializer_list<KICAD_T>. 2022-08-20 10:28:11 +01:00
Mikolaj Wielgus 978f01553b Sim Model Editor: Serialize models in fields
Implemented serialization and deserialization of models in symbol fields
through the SIM_VALUE class. We don't carry the Spice legacy of
case-insensitive suffixes, instead we conform to the SI standard (i.e. M
is Mega, not milli, P is peta, p is pico).

Parameter grid value validation is implemented by simply not allowing
any characters that will make the value invalid (instead of highlighting
the field in a red color). This will likely be changed at some point in
the future.
2022-07-30 02:25:34 +00:00
Marek Roszko a8505d9c76 SEARCH_RESULT -> INSPECT_RESULT
To fix the name squatting it's doing for future functionality
2022-07-29 20:01:10 -04:00
Seth Hillbrand ff54b8c718 Overplot schematic symbol fields and pins
In the absence of z-ordering, we need to ensure that pin text and symbol
fields are always visible in plots as they are in the schematic window.
We do this by overplotting the fields/pins when symbols overlap each
other.

This can be removed if/when we implement https://gitlab.com/kicad/code/kicad/-/issues/2211

Fixes https://gitlab.com/kicad/code/kicad/issues/11969
2022-07-05 16:39:53 -07:00
Jeff Young e4798199c6 Handle alt pins in plot code.
Fixes https://gitlab.com/kicad/code/kicad/issues/11728
2022-06-10 22:38:01 +01:00
Jeff Young 034b57d9c0 When reannotating keep existing prefix in most cases.
(Execption is reannotating entire schematic, in which case we reset
all of them.)

Fixes https://gitlab.com/kicad/code/kicad/issues/11379
2022-04-13 23:38:45 +01:00
Jeff Young 8358685920 Dual-purpose IsMovableFromAnchorPoint to keep from moving symbols off-grid.
Fixes https://gitlab.com/kicad/code/kicad/issues/11360
2022-04-11 12:02:20 +01:00
Wayne Stambaugh 239f0214ac Eeschema: add support for default schematic symbol instance data.
Prior to fixing the schematic file change churn do to instance data
changing to the last selected sheet instance, the symbol instance data
was set rather than empty.  This change allows for users to set the
default instance data which is used for every new instance of the
schematic.

ADDED: Default schematic symbol instance data (unit and reference, value,
       and footprint fields) can be set to be used as the default settings
       for all new instances of the schematic.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/11113
2022-04-09 07:49:36 -04:00
Jeff Young 8eb10c41d8 Name any unnamed fields so they don't clobber each other.
Fixes https://gitlab.com/kicad/code/kicad/issues/10039
2022-03-22 18:08:05 +00:00
Seth Hillbrand 8c36ba3653 Explicitly give unit values
Removes the ability to hide symbol units in file formats.  This was
mostly the case for a while but there remained corner cases where we
left a default/hidden option

Fixes https://gitlab.com/kicad/code/kicad/issues/10888
2022-03-02 16:01:08 -08:00
Jeff Young d60ed70d54 Sync all fields between units when symbol is edited.
Fixes https://gitlab.com/kicad/code/kicad/issues/10610
2022-02-17 12:42:10 +00:00
Jeff Young f11b8011cd Separate plotting into background and foreground.
Fixes https://gitlab.com/kicad/code/kicad/issues/10390
2022-02-10 20:33:06 +00:00
Jeff Young 3409783d9f Break sch_text.h/.cpp into sch_text and sch_label.
Also moves SCH_NETCLASS_FLAG to SCH_DIRECTIVE_LABEL, and remaps Altium
harnesses from SCH_TEXT to SCH_DIRECTIVE_LABEL.
2022-01-28 21:38:15 +00:00
Marek Roszko c91d3e3cf9 Remove some more wxPoint 2022-01-01 14:12:20 -05:00
Marek Roszko d1552c3fec Some more wxPoint removal 2022-01-01 12:11:21 -05:00
Marek Roszko c4c56de708 Neurotically update position wxPoint usages 2022-01-01 11:55:51 -05:00
Jeff Young 889970a449 SCH_NETCLASS_FLAGs and SCH_FIELDs for labels.
ADDED: a new label type for netclass flags.
ADDED: the ability to define fields on labels.
2021-12-24 16:13:27 +00:00
Jeff Young 2bc86fa0a8 Shapes for schematic.
ADDED arc, circle and rectangle shapes for schematic.  Shapes support
line styles and fill colors.

CHANGED sheet background color in Edit Text & Graphics Properties to
fill color (and it now affects shapes).

Pushed STROKE_PARAMS down into common and moved all shapes to using it
for stroke descriptions.
2021-12-23 20:36:07 +00:00
Jeff Young 552f053a55 Remove pins from symbol hit-testing.
Fixes https://gitlab.com/kicad/code/kicad/issues/8508
2021-09-23 22:07:51 +01:00
Jeff Young f221220fe2 Rename layer ids file.
It hasn't had anything to do with colors or visibility for some time
now.
2021-07-29 16:03:25 +01:00
Wayne Stambaugh cb72da294a More NULL expunging. 2021-07-16 16:13:41 -04:00
Wayne Stambaugh ee3eac325d Expunge the use of the word part from Eeschema code. 2021-06-15 08:32:11 -04:00
Wayne Stambaugh 71c183d7bb Rename LIB_PART to LIB_SYMBOL. 2021-06-14 07:11:17 -04:00
Wayne Stambaugh fbc135e69f Rename SCH_COMPONENT to SCH_SYMBOL. 2021-06-10 10:34:49 -04:00
Wayne Stambaugh 9ebabb222c Pass objects by reference instead of on the stack. 2021-06-08 10:09:38 -04:00
Jeff Young 0598c82972 Terminology (use present tense for flags). 2021-05-31 12:26:44 +01:00
Jeff Young f7ae819430 Don't confuse annotation prefix *letters* with root annotation.
Given a symbol U12A, some parts of the code were assuming the prefix was
'U' while others were assuming 'U12'.  Further complication arose when
there were '?' in the library version.

Fixes https://gitlab.com/kicad/code/kicad/issues/8223
2021-04-17 12:30:40 +01:00
Jeff Young df5f010514 Bug fixes for fields when editing a symbol from the schematic.
1) Don't reset value when name changes
2) Don't fire events when initialising dialog
3) Make sure when symbol is saved back to schematic that only current
instance has its ref updated, but that all instances have their other
fields updated.
4) When saving symbol back to board always use the fields from the
editor and not the (alias-specific) ones from the library.

Fixes https://gitlab.com/kicad/code/kicad/issues/8159
2021-04-09 17:14:53 +01:00
Wayne Stambaugh 925b6d9387 Eeschema header housekeeping round 2. 2021-03-25 17:55:16 -04:00
Jeff Young 7a13ad7b17 Consistent naming. 2021-03-19 23:06:19 +00:00
Jon Evans 18037e2f65 Rework bitmap system to load from archived PNGs
Bitmaps are now identified by an enum class instead of by pointers.
Bitmap loading and caching is now handled by a class in common, and
we no longer compile most bitmaps into the binary, so there is no
longer a bitmaps static library.

Instead, bitmaps are archived to a .tar.gz file which is installed
in ${KICAD_DATA}/resources/images.tar.gz

The source PNGs are checked in to Git as the original CPP files were,
so that people can build without the required dependencies to convert
SVGs to PNGs.

Initial support is also added for dark theme icons, although this
is not yet exposed in the GUI.

Stubs are present for multi-resolution image resources, but this is
not fully-baked yet and could use some refinement.
2021-03-11 08:37:35 -05:00
Dominik Wernberger e2aa7be4b3 Added a lot of consts and refactored a few lines 2021-03-08 12:49:48 -08:00
Jon Evans 720147d272 Remove transitive inclusion of bitmaps.h 2021-03-07 16:08:57 -05:00
Jeff Young 8a33542bcd SCH_COMPONENT::GetField() expects a vector index, not a field id.
Check this at compile time.  Callers wanting to use an index now must
use SCH_COMPONENT::GetFields()[i] instead.

Fixes https://gitlab.com/kicad/code/kicad/issues/7757
2021-02-28 15:10:37 +00:00
PJM d8089ed54a Eeschema: Adds wire when dragging directly connected labels
CHANGED: KiCAD allows connecting components directly together in
schematics.  If the user drags one of the components, KiCAD
adds a wire to keep the conection intact.  It should do the same for
net and global labels but it doesn't.

This MR adds net and global labels to the list of items that can connect
to other items.

Fixes https://gitlab.com/kicad/code/kicad/issues/7713
2021-02-26 22:56:28 -08:00
Wayne Stambaugh 1786ae8773 Eeschema: use symbol nomenclature for object file naming. 2021-02-24 08:48:02 -05:00
Renamed from eeschema/sch_component.h (Browse further)