Seth Hillbrand
8c19b4b6ae
pcbnew: Adding arcs to PNS
...
This is allows ARCs in tracks to be synchronized with
the PNS router. Note this does not yet include the UI components
to route curved traces
2020-02-21 16:11:41 -08:00
jean-pierre charras
f2518a5120
ADDED: pad fabrication property, as required in latest Gerber file specification.
...
Property is a pad info used mainly for fabrication or test.
Currently, supported properties are:
BGA property (variant of SMD pad)
Fiducial (global to the board or local to the footprint)
Test Point
Heat sink
Castellated.
And are used in Gerber files (copper layers and drill files)
Increment BOARD_FILE_VERSION to 20200104
2020-01-06 16:37:35 +01:00
Seth Hillbrand
b5f021ff9f
Cleanup: Replace push_back with emplace_back
...
In cases where we create a new item and immediately push into a
container, the emplace idiom is faster and more efficient.
2019-12-05 13:41:21 -08:00
jean-pierre charras
a1fe8cfa5a
Minor changes: cleanup code and prepare code to add more attributes to Object Attributes (.TO)
2019-09-18 11:48:49 +02:00
jean-pierre charras
29ca96cfe7
Gerber drill file: Modify a aperture attribute for oblong holes (slots).
...
Oblong holes (slots) use now a aperture attribute similar to round holes.
(The previous attribute "slot" is now deprecated)
However they have a specific aperture, and a comment is added in drill files for these apertures.
2019-06-25 09:43:29 +02:00
jean-pierre charras
f6aed7c99a
Gerber plotter: rename UseX2Attributes() to UseX2format, and fix incorrect/outdated comments.
2018-12-09 10:23:07 +01:00
jean-pierre charras
0b890b4d1d
Drill files generation: add 3 structured comments in NC (Excellon) drill files and remove duplicate code.
2018-11-24 08:51:58 +01:00
Andrzej Wolski
834d9335dd
Do not plot zero width oval holes in Gerber X2 drill files
...
In case there are zero width oval holes on the PCB,
it is safer to not plot them at all, rather than plotting
with width arbitrarily increased to 10 mils.
This also makes Gerber outputs consistent with Excellon outputs.
2018-06-17 16:26:23 +02:00
jean-pierre charras
93e75af388
Rename plot_auxiliary_data.h file to gbr_metadata.h, according to the class names defined by this file
2018-05-17 08:07:29 +02:00
jean-pierre charras
8552f3fedf
fix code after renaming files
2018-01-29 22:00:44 +01:00
jean-pierre charras
e499d337d8
rename files: update filenames in sources
2018-01-28 19:12:26 +01:00
jean-pierre charras
59c527c40c
Excellon drill file generation: allows 4 digits in mantissa in Tool Information command when units are inches.
...
Fixes: lp:1738657
https://bugs.launchpad.net/kicad/+bug/1738657
2017-12-20 17:49:25 +01:00
jean-pierre charras
bdc6a5950b
rename plot_common.h to class_plotter.h, a better name, consistent with other class definitions.
2017-11-16 15:53:30 +01:00
jean-pierre charras
5d252639fa
Refinement in Gerber drill file: add %TF.FilePolarity,Positive*% in header.
2017-06-30 18:36:26 +02:00
jean-pierre charras
f77db7b4b9
Fixes: lp:1690840 (Pcbnew crashes when creating a drill file)
...
https://bugs.launchpad.net/kicad/+bug/1690840
2017-05-16 13:00:54 +02:00
jean-pierre charras
afe92c7bfc
Pcbnew: Add creation of Drill Files in Gerber X2 format.
...
Gerbview: add support of drill files in Gerber format.
Fix also an issue in drill dialog: Axis choice is now common to plot a drill files.
2017-05-01 12:43:40 +02:00