When dragging a bus the entry is connected to the bus so the wire
connected to the entry (if any) needs to stretch.
While an entry can connect in the middle of bus, it cannot connect
in the middle of a wire.
Fixes: lp:1849973
* https://bugs.launchpad.net/kicad/+bug/1849973
Copy/Paste should keep the original items' designation for all units and
conversion type. If it was specified in the original copy, we should
keep the same specification when pasting (but update for the current
frame)
The new connectivity algorithm had a tendency to cleanup
globally, but that could insert undo records from other sheets
into the current screen's undo stack. Needless to say, this
was a recipie for segfaults.
Fixes: lp:1846247
* https://bugs.launchpad.net/kicad/+bug/1846247
Right click is a pointing operation combined with a request for the
context menu. We need to highlight the user's intended object when they
have moved their mouse to a new element instead of showing the context
menu for the selected object.
However, in cases where the selection is difficult to make, it is
sometimes helpful to select the item first, then right-click. In these
cases, we keep the selection where the mouse remains inside the selected
object's bounding box.
When placing a new component in the schematic, this allows the user to
iterate through all units in the selected component without re-opening
the choose part dialog. It also allows the optional addition of
multiple copies of the same component to be placed in the schematic.
Fixes: lp:1806217
* https://bugs.launchpad.net/kicad/+bug/1806217
Adding a field to a selection changes the bounding box and count for
rotation. This can cause odd offsets when the field is rotated against
the selection center rather than the bounding box as well as with the
component.
Fixes: lp:1849078
* https://bugs.launchpad.net/kicad/+bug/1849078
The break wire command will break all wires at a point. If there are
multiple crossing wires, we need to check to see if a junction might be
required to reflect the new connection.
Fixes: lp:1848450
* https://bugs.launchpad.net/kicad/+bug/1848450
When we add enough SHEET_PINs that the vector has to grow, it
re-allocates the vector causing our for-loop to get its knickers
tied in a knot.
Fixes: lp:1842394
* https://bugs.launchpad.net/kicad/+bug/1842394
1) When sheet pins are on 3 or more sides there's no point in switching
the orientation to vertical.
2) Careful that we don't cause the sheet to walk when rotating and the
sheet-name or file-name is longer than the side it's on.
Fixes: lp:1841714
* https://bugs.launchpad.net/kicad/+bug/1841714
Also, if it can't be loaded then at least initialize it so that we
don't crash later (trying to access a NULL screen).
Fixes: lp:1841801
* https://bugs.launchpad.net/kicad/+bug/1841801
Saving individual parts of a schematic can break the schematic. This
moves the schematic save option to save all sheets rather than just the
current sheet.
Fixes: lp:1840383
* https://bugs.launchpad.net/kicad/+bug/1840383
They're now used for bus definition control characters.
Also fixes the sheet pin edit dialog to correctly escape/unescape
netnames.
Fixes: lp:1840834
* https://bugs.launchpad.net/kicad/+bug/1840834
1) don't ASSERT; use exceptions (which can be caught) instead.
2) clean up LIB_LOGGER so it's only used during sync
3) fix typos in wxLogMessage() calls so they produce output.
4) throw on unrecognized token in loadContent().
5) if clipboard can't be pasted as content then paste as text.
Fixes: lp:1840172
* https://bugs.launchpad.net/kicad/+bug/1840172