With the implementation of the legacy schematic plugin, any I/O error
when parsing the schematics would prevent the entire schematic from
being loaded. This change restores (somewhat) the previous behavior
where as long as the root schematic is loaded properly, then all of
the remaining sub-sheet will attempt to load.
Add GetError() method the SCH_PLUGIN object to allow for partial
schematic loading.
Check the error message contents when no exception was caught to warn
the user of any accumulated errors.
Fixes lp:1690644
https://bugs.launchpad.net/kicad/+bug/1690644
Fixes the connection display and dragging behavior of wires,
busses and their entries.
The implemented drag logic is:
-busses and bus-bus entries drag each other when connected at endpoints
-wires and wire-bus entries drag each other when connected at endpoints
-entries do not drag wires or busses when connected to wire middles
-wire-bus entries do not drag busses
The implemented connection logic is:
-bus-bus entries connect busses to busses but not wires
-wire-bus entries connect wires to busses but not wire to wires or
busses to busses
It turns out the fastest way to update wxDataViewCtrl is to nuke the
model and rebuild it from scratch rather than via
ItemAdded()/ItemDeleted() update notifications.
Fixes: lp:1734773
* https://bugs.launchpad.net/kicad/+bug/1734773
CHANGE: In Eeschema, when placing a component directly over an existing
wire, the wire is automatically removed where it shorted pins.
This helps workflow in Eeschema, allowing one to quickly add components
to existing lines.
Fixes: lp:1678449
* https://bugs.launchpad.net/kicad/+bug/1678449
This is the last of the object save/load code that was not moved into
the SCH_LEGACY_PLUGIN object. All schematic and library I/O is now
performed in the SCH_LEGACY_PLUGIN object and as been removed from the
schematic and library objects.
The old single symbol file format has been replaced with the normal
symbol library file format since there was no difference between them
except the SYMBOL token. The SYMBOL token was no longer being read
since the introduction of the SCH_LEGACY_PLUGIN symbol library loader.
Update the Doxygen comments in all of the modified files.
BreakSegment now breaks a known segment and BreakSegments
breaks all segments. This allows functions to break a
segment without needing to iterate through the whole list.
Changes to the schematic shouldn't be made
where the user isn't looking. Removing the
cleanup in ERC and netlisting prevents
unintended consequences
CHANGE: ERC and Netlist calls do not modify schematic
SCH_LINE can represent a bus, wire or graphic line. Checking
for the corner needs to distinguish between these types.
Fixes: lp:1635984
* https://bugs.launchpad.net/kicad/+bug/1635984
Make the user prompt an HTML control for improved layout.
Fix some column title sizing issues. This is not a complete fix but
it seems better than the default sizing done by wxWidgets.
Use symbol terminology instead of part and/or component.
Create trace string source files for a common place for them and their
Doxygen comments.
Don't back up schematic files unless the user requests a remap.
Back up all files that could be changed by a remap including the
schematic file(s), cache library, project file, and rescue library
files.
Use an HTML control instead of a static text control for improved layout
of the user remap prompt.
Improve the user prompt in the remap dialog to make it clear that changes
will be made to project files.
Duplicated aliases were given " (copy x)" suffix. There are two
problems: aliases cannot contain spaces and the string was translatable
which could create more issues. Now duplicated aliases receive "_x" suffix.
Change the legacy schematic plugin to preserve illegal LIB_ID characters
when load schematics prior to version 4.
Check for illegal LIB_ID symbol names during project rescue. Rename and
rescue any symbols with illegal LIB_ID names.
Add static methods to LIB_ID object for testing for and fixing names
with illegal characters so there is uniform code for doing so.
Update the Eagle plugin symbol loader to fix symbol names using the new
LIB_ID fix illegal names method.
Fixes lp:1732236
https://bugs.launchpad.net/kicad/+bug/1732236
Dragging a full line that is connected to a component
now drags the component as part of the block, maintaining
connections.
Fixes: lp:1167714
* https://bugs.launchpad.net/kicad/+bug/1167714
Removed cut & copy toolbar icons in the schematic editor, as they
were inaccessible. One cannot have an item selected and move the
mouse outside the canvas area due to autopanning.
Added paste icon to the library editor.
Tree nodes now have an additional field 'InTree' to determine
if the view is aware of its existence. This way, there is no need
to rebuild the data structures from scratch when they need to be
filtered.
Library Editor updates its working copy of the edited part every time
it is modified. If LIB_EDIT_FRAME::PlacePin() calls OnModify() too early,
the working copy does not include the last change.
Updates LIB_ID::LibItemName field when a part is renamed and LIB_PART
name when a new LIB_ID is set.
Similarly, LIB_ID::LibNickName field is updated when a library set, but
there is no easy way to assign library when LIB_ID::LibNickName is
modified.
LIB_PART name is stored in three places that might be changed
independently:
- the first LIB_ALIAS in m_aliases
- LIB_FIELD with VALUE ID
- m_name wxString field
This is potentially leads to an incoherent LIB_PART state. To prevent
this, all fields are changed using only one method: LIB_PART::SetName().
LIB_PART::m_name has been removed as the same information is available