This way the net names can be inspected in eeschema and cross-probing works.
Testcases updated for the name changes
CHANGED: all unconnected pins are now included in the netlist with no_connect_ prefixes
This behavior provided shorter net names, but was confusing if
the user gives an explicit strong driver in the subsheet but not
one in the parent sheet.
Testcases updated for net name changes; connectivity is the same
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4201
Depending on what order the subgraphs are processed in, it's
possible to hit a case where the parent sheet renames a bus
member before the bus neighbor renaming logic runs. In this
case, we don't want to apply the bus neighbor logic as it will
break connectivity to the parent sheet if that bus was not
also renamed (for example, if the hier ports only make net
connections and not bus connections)
Fixes https://gitlab.com/kicad/code/kicad/-/issues/6887
In particular, there was a typo that kept library values from being
updated, and there was missing logic to fetch the various field names
from the library parts (and the change-to part).
Also implements some performance gains by desisting from copying
LIB_FIELDs around every time we want to look at them.
Fixes https://gitlab.com/kicad/code/kicad/issues/6733
Fixes https://gitlab.com/kicad/code/kicad/issues/6749
The groundwork has now been laid for per sheet instance data. Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.
ADDED: Support for user defined schematic page numbers.
Previously disambiguation was looking for exact matches,
but vector buses are permitted to have different ranges and
still participate in merging, so they need to be disambiguated.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5925
The use of printf, wxLogDebug, and std::err/std::out causes excessive
debugging output which makes finding specific debugging messages more
difficult than it needs to be.
There is still some debugging output in test code that really needs to
be moved into a unit test.
Add debugging output section to the coding policy regarding debugging
output.
This moves the program-specific code (e.g. BIU files) into
the program tests.
Also, create title_block.cpp to break a dependency that pulled
in eda_text.cpp when using the TITLE_BLOCK object.
- Fix file extension for new project
- Fixes for exceptions on MSW
- Fix some ASAN issues
- Allow SETTINGS_MANAGER to run headless
- Don't flag schematic as modified after schematic setup is closed
- Don't automatically unload projects when LoadProject is called
- Don't unload project if it's the same as the current one
- Make sure to properly init/de-init template field names
CHANGED: All mandatory fields in derived symbols can be edited. This
not only includes the field value but also all text properties.
Kill the dual datasheet variable storage which caused many datasheet
bugs over the years. The datasheet is now always stored in the data
sheet field.
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of. Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.