This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.
The new file formats are now the default in both the schematic and symbol
library editors. Existing symbol libraries will be saved in their current
format until new features are added to library symbols. Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted. Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.
When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier. The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.
The next save after loading a legacy schematic file will be converted to
the s-expression file format. Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.
Appending schematics requires that the schematic to append has already been
converted to the new file format. This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.
The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol. This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed. It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.
When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded. Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.
Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically. No external manipulation of this library cache should ever
occur.
ADDED: S-expression schematic and symbol library file formats.
It looks good, but non-mandatory fields have an ID of -1, so it
doesn't actually work. Some places got around this by converting
the ID to unsigned, but this just hides the real issue from
unsuspecting coders.
Fixes https://gitlab.com/kicad/code/kicad/issues/4140
When searching for fields, the code was sometimes comparing translated and not translated names.
This is an issue for mandatory fields, in non English languages.
Translated field names should be used only in messages.
The parents are the only items that live in the RTree, so the rebuild
check needs to recurse into the sub structure to check for selection
Fixes https://gitlab.com/kicad/code/kicad/issues/3858
The RTree does not have a deterministic iterator, so extracting items
may be in arbitrary order, causing issues as the schematic appears to
change when comparing to previous revisions.
This uses the SCH_ITEM comparison operator to for ordering by type, then
by custom sorting within type.
For the netlist, we choose the first available unit in the sheet for
each component.
Fixes#3811 | https://gitlab.com/kicad/code/kicad/issues/3811
Scope: NETLIST_ITEM, CONNECTION_TYPE, ELECTRICAL_PINTYPE,
NET_CONNECTION, NETLIST_ITEM, GRAPHIC_PINSHAPE
Note, the pin type enum had PT_ added to the front to prevent
shadowing of the INPUT symbol on msys2 (see discussion at
c17c9960d8)
This moves EESchema DLIST structures to rtree. These changes are more
fundamental than the pcbnew changes from 9163ac543888c01d11d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
Derived symbols were causing the symbol properties grid to assume that
the reference could not be edited because derived symbols inherit the
reference from the parent symbol. The flattened symbols in the schematic
still have the parent set which cause the issue. Clearing the parent of
the flattened symbol resolves the issue.
Fix a minor bug in the symbol information of derived symbols show in the
symbol chooser dialog.
Fixes#3723https://gitlab.com/kicad/code/kicad/issues/3723
The schematic symbol swap function still had the old pin map swapping
code which overwrote the correct pin maps that were rebuild after the
library symbol was update. Duh!
Fixes kicad/code/kicad#3661
The new symbol library changes left stale pointers in the connection
graph because the SCH_COMPONENT object pins were not always getting
updated when a new copy of the library symbol was updated.
Force a full update of the connection graph whenever the schematic
library symbol links are refreshed. This seems like overkill but it
ensures that there a no stale libraries items left in the connection
graph.
Fixes kicad/code/kicad#3658
This change completely removes the LIB_ALIAS design pattern an replaces
it by allowing LIB_PART objects to inherit from other LIB_PART objects.
The initial implementation only allows for single inheritance and only
supports the mandatory fields in the derived part because that is all
that the current symbol library file format will support. Once the new
file format is implemented and saving to the old file format is deprecated,
more complex inheritance will be added. The LIB_ALIAS information saved
in the document files was move into the LIB_PART object. This change
impacts virtually every part of the schematic and symbol library editor
code so this commit message is woefully incomplete.
REMOVE: Removed the symbol aliases concept from the schematic and symbol
editors and the symbol viewer.
NEW: Replace the symbol alias concept with simple inheritance that allows
a library symbol to be derived from another library symbol.
This only applies to the root symbol when the datasheet field is not
empty and the datasheet for root symbol alias in the document file is
empty. Use the root symbol datasheet field value when adding a new
symbol that meets this criteria.
https://bugs.launchpad.net/kicad/+bug/1830083
Fixes lp:1830083
Force the symbol library links whenever the symbol library table has been
modified. This will use the cache as a fallback when a library has been
removed that contains links in the schematic rather than display.
Fix the SCH_COMPONENT symbol resolver when falling back to the cache. The
resolver was using the LIB_ID ':' notation which was failing. Replacing
':' with '_' fixed this issue. This was also an issue when generating the
symbol message panel information.
Convert wxLogDebug to wxLogTrace in symbol resolver code path. Add new
trace type KICAD_SYM_RESOLVE.
Fixes lp:1821606
https://bugs.launchpad.net/kicad/+bug/1821606
In the component, an m_unit/m_convert element is 1-indexed as opposed to
the library where they are 0-indexed. The 0-index in the library is
reserved for those elements that are shared across all conversion/unit
whereas it is invalid for the component.
Fixes: lp:1824764
* https://bugs.launchpad.net/kicad/+bug/1824764
(cherry picked from commit c4be74a9d0)
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
Uses existing grouping in SVG output. Sets schematic components as a
grouped element in SVG as well as pcbnew elements per layer.
Fixes: lp:1011754
* https://bugs.launchpad.net/kicad/+bug/1011754
No dangling symbol for text items with a NO-CONNECT.
DanglingStateChanged doesn't work with dangling flag aggregators
(which return true if any child is dangling).
Then again, we don't actually use any of the aggregators anyway
so I removed them.
Fixes: lp:1799589
* https://bugs.launchpad.net/kicad/+bug/1799589
Support all symbol orientations. (Yes, SCH_COMPONENT said only the
first 8 were used, but it lied.)
Fix cases where SetTextAttributes() was overwriting previously-
set justifications.
Correct rotation of vertical text.
Fix issue where bold global label would affect thickness of next
label's outline.
Previously, when creating a new instance of a sheet, the full set of references
was cleared.
Moreover, if this sheet has sub-sheets, the annotation was incorrectly handled
Now only (and all) new sheet path(s) created have a reference cleared, as expected.
(new sheet paths can be more than one, if the new instance of the sheet has sub-sheets)
Fixes: lp:1789048
https://bugs.launchpad.net/kicad/+bug/1789048
... and GetMsgPanelInfo.
Step 4 in the g_UserUnit eradication effort.
Also removes a couple of conversion routines that were close
enough to extinction.
(cherry picked from commit c75da51)
Clearing annotations should only clear the settings that can be set by
the matching annotate function. Even in components where the units are
functionally the same, the unit choice should be retained as there are
often other considerations when chosing the unit.
Fixes: lp:1769457
* https://bugs.launchpad.net/kicad/+bug/1769457
1) Commit in-progress edits before closing preferences.
2) Handle default fields in Symbol Fields Editor.
3) Save state of checkboxes in Symbol Fields Editor.
Nets assigned by power pins are weak, meaning they are valid
as long as there is nothing else attached to such pins. This patch
checks whether there are other wires or pins attached to a power pin
before placing a global net label.
Fixes: lp:1755191
* https://bugs.launchpad.net/kicad/+bug/1755191