Don't open-code knockout text shape generation in several different
places.
Make sure triangulated knockout text gets clearance added when
specified.
Collapse duplicated footprint text item plot routine (they're no
longer any different from plotting pcb text items).
(cherry picked from commit c71cf21e2f)
Also fixes a bug where we didn't triangulate at all when the char
count didn't warrant the likely overhead of spinning up a
thread_pool.
And fix another bug where EDA_TEXT::GetRenderCache() wasn't using
the given font.
Also reverts using the cache for drawing-sheet text. The text
items are created from scratch from the data items each time
they're drawn, so there's never an existing cache to make use of.
Instead, we now check that the item is in the view, using a very
approximate bounding box generator (because even generating a
real bounding box shows up large in profiles).
And, lastly, fixes a bug where EndPos was never considered in
DS_DATA_ITEM::IsInsidePage().
Fixes https://gitlab.com/kicad/code/kicad/-/issues/14822
(cherry picked from commit f35a88ce0b)
1) Don't fracture font glyphs when generating them; we're going
to fracture during triangulation anyway.
2) Don't check for self-intersection when deciding to fracture.
It costs nearly as much as the fracture does.
3) Cache drawing sheet text.
4) Use the current font when checking for cache validity.
5) Parallelize glyph triangulation.
6) Don't invalidate bounding box caches when offset by {0,0}
7) Use the glyph cache when generating text effective shape.
8) Short-circuit NormalizeJustification() if its center/center.
9) Don't triangulate for GuessSelectionCandidates()
10) Avoid sqrt whenever possible.
11) Pre-allocate bezier and SHAPE_LINE_CHAIN buffers.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/14303
(cherry picked from commit 4ed267394a)
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
(cherry picked from commit b41d446f58)
Includes changing the class hierarchy so that dimension objects inherit
from PCB_TEXT rather than containing a PCB_TEXT member variable.
(cherry picked from commit 23accffc6d)
We used to use the bold setting, but since PCBNew allows you to
directly define the width you end up with settings in between normal
and bold that get clamped to the normal max.
Fixes https://gitlab.com/kicad/code/kicad/issues/12367
Since EDA_TEXT is a base class, we can just force the child classes to pass the correct iu scaled size
ALLOW_BOLD_THICKNESS removed because it's a pre-custom font holdover
Also moves most navigation code to SCH_NAVIGATION_TOOL.
Also changes page number href to anchor syntax ('#foo').
Also adds hypertext processing to SCH_TEXTBOXes.
Also adds combobox with schematic pages to text properties dialog.
The problem is that "real" page numbers can be duplicated, so we work around it
by using virtual page numbers instead which are guaranteed unique.
Example "goto:3" will go to page 3. If customised page numbers are used such as
a, b, c, then to go to page b, we should specify goto:2 (i.e. the virtual page
number).
Count() returns unsigned values. Since, we subtract 1 from this value,
if the count is 0, we will underflow the unsigned value, creating an
extremely large value that we multiply by the interline spacing.
(cherry picked from commit d29d981784)