A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
(cherry picked from commit b41d446f58)
Includes changing the class hierarchy so that dimension objects inherit
from PCB_TEXT rather than containing a PCB_TEXT member variable.
(cherry picked from commit 23accffc6d)
EDA_ITEMs are responsible for giving their parent a crack at it if
they failed to resolve it. This recurses all the way up to the schematic/
board, and then to the project.
Cross-reference handling is also move to the EDA_ITEMs. It must be done
before bubbling up so that we don't end up in loops. (The aDepth parameter
will break the loop, but without having done anything useful.)
Fixes https://gitlab.com/kicad/code/kicad/issues/13541
Also adds some debugging to try to catch dangling pointers.
Also adds a cache for group bounding boxes (which will be expensive
to calculate for large groups).
Fixes https://gitlab.com/kicad/code/kicad/issues/12875
This function convert a text shape to a set of polygons for the 3D viewer.
Texts shapes are a bit special and can generate a lot of small overlapping polygons.
These polygons are now merged before being added to the list of polygons handled
by the 3D viewer draw functions.
Locally merging polygons is usually not efficient but in this case it can speedup
the 3D viewer (up to 10x).
Mainly noticeable for silkscreen layers when the "copper" thickness is shown
Since EDA_TEXT is a base class, we can just force the child classes to pass the correct iu scaled size
ALLOW_BOLD_THICKNESS removed because it's a pre-custom font holdover
When building the connectivity database, we should not be using the
connectivity to check for shapes.
To make this deterministic, we introduce two flags (ALWAYS_FLASH and
NEVER_FLASH) that are used with connectivity building to determine
whether a pad is flashed for connectivity or not. ZONE <-> PAD/VIA
connectivity will be checked with ALWAYS_FLASHED and all other
connectivity will be checked with NEVER_FLASHED if they are marked for
potential annular ring removal. If they are not marked for removal,
they will be checked ALWAYS_FLASHED.
Fixes https://gitlab.com/kicad/code/kicad/issues/11114
Also fixes a bug where outline fonts weren't being handled for footprint
text in 3D Viewer, and a copy/paste error in stroke font handling for
both PCB and footprint text in 3D Viewer.
Fixes https://gitlab.com/kicad/code/kicad/issues/10319
They don't define a KiCad string class, so the header file name was
somewhat misleading. But the fact that they didn't match definitely
made coding more difficult.