Commit Graph

241 Commits

Author SHA1 Message Date
Tomasz Wlostowski d937fadd6f Migrate RC_ITEM to use shared_ptr 2020-08-13 14:50:59 +02:00
Jeff Young f4ab14f32d Performance improvements for SchematicCleanup().
Fixes https://gitlab.com/kicad/code/kicad/issues/4563
2020-08-10 12:41:52 +01:00
Jeff Young c56599ab07 Allow ERC/DRC markers to be deleted without deleting exclusions.
Fixes https://gitlab.com/kicad/code/kicad/issues/4953
2020-08-02 22:45:48 +01:00
Jeff Young 7340c97ef9 Undo for schematic-wide operations.
Editing value/footprint fields of multi-unit components.
Find/Change.
Annotation.
Back annotation.

Fixes https://gitlab.com/kicad/code/kicad/issues/2122

Fixes https://gitlab.com/kicad/code/kicad/issues/4869

Fixes https://gitlab.com/kicad/code/kicad/issues/3933

Fixes https://gitlab.com/kicad/code/kicad/issues/4871

Fixes https://gitlab.com/kicad/code/kicad/issues/3899
2020-07-13 12:32:17 +01:00
Jeff Young c48f4272f3 Collapse a level out of the zoom settings.
The APP_SETTINGS_BASE now holds the list of zoom factors, and
the old legacy (screen-based) code has been removed.
2020-06-13 22:44:16 +01:00
Jeff Young f84406009b Push a couple of layers of indirection out of grid settings. 2020-06-13 11:35:56 +01:00
Jon Evans 2164501b06 Don't reparent symbol fields
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4540
2020-05-25 17:47:50 -04:00
Jon Evans 7c7b7f41da Move SCH_SCREEN project access to SCHEMATIC
SCH_SCREEN no longer needs to be a KIWAY_HOLDER
2020-05-20 22:27:48 -04:00
Jon Evans b6d7bc36d0 Ensure component bounding boxes are correct
This was causing junctions to not always be added on wire
segments that overlapped component pins, because the pin
might not be part of the component bounding box before
UpdateLocalLibSymbolLinks() is called.  When the bbox
was never updated, these symbols weren't collected by
the rtree query for objects overlapping a point.
2020-05-20 18:50:09 -04:00
Jon Evans fbc42a8cb5 Move schematic defaults to SCHEMATIC and add some missing settings entries 2020-05-20 00:03:23 -04:00
Jon Evans f4d7c323f5 Coverity fixes 2020-05-18 22:58:28 -04:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Jeff Young 301ac3461c Fix some more pen width issues from global removal.
Fixes https://gitlab.com/kicad/code/kicad/issues/4408
2020-05-12 15:20:17 +01:00
jean-pierre charras bc24d8e957 Fix typo and I18N string 2020-05-10 16:55:15 +02:00
Jon Evans c92181621e Use strong check for bus label when netlisting
Fixes #4318
2020-05-06 18:27:03 -04:00
Wayne Stambaugh aa9e74493f Eeschema: fix netlist creation crash when opening spice simulator. 2020-05-05 18:35:27 -04:00
Wayne Stambaugh a06fa22b8a Eeschema: remove rogue calls to SCH_SCREEN::UpdateSymbolLinks().
SCH_SCREEN::UpdateSymbolLinks() should only be called when working with
the legacy schematic file format.  Add schematic symbol library symbol
links should be set using SCH_COMPONENT::SetLibSymbol() which updates
the symbol link and pin map accordingly.

Change the schematic symbol LIB_ID edit dialog to properly use the new
SCH_COMPONENT::SetLibSymbol() function.
2020-05-05 12:52:17 -04:00
Wayne Stambaugh 169f63a6c0 Eeschema: make schematic sharing truly safe across all designs.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects.  It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic).  This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet.  This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references.  It also allows the root schematic from one project
to be uses as a sub-sheet in another project.

When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs.  This is done to ensure there
are no sheet path instance clashes between projects.  That being said,
there are no checks for this.  It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Jeff Young da1a89fc7e Allow users to control the order of sheets through sheet fields.
Fixes https://gitlab.com/kicad/code/kicad/issues/2394
2020-05-03 23:27:30 +01:00
Jeff Young 0370eff7ba Add sheet number processing to sheet fields.
Also fixes a bug where we were depending on the old deque stuff's
deterministic traversal, which isn't provided by the new RTree stuff.

Fixes https://gitlab.com/kicad/code/kicad/issues/2433
2020-05-03 20:56:32 +01:00
Jon Evans 2eaefb4874 Improve performance of schematic load and connectivity
Store component paths and references efficiently
Remove redundant calls to RecalculateConnections
2020-04-30 19:53:25 +00:00
Ian McInerney 99dcadf7e6 Introduce new KI_FALLTHROUGH macro
Annotate purposeful fallthroughs in switch statements with the
KI_FALLTHROUGH macro.
2020-04-25 00:44:09 +01:00
Jeff Young a286cb5a8f Keep labels on dragged wires.
Fixes https://gitlab.com/kicad/code/kicad/issues/2107
2020-04-19 18:24:39 +01:00
Jeff Young 2b6089240a Change super/subscript syntax to ^{foo} and _{foo}. 2020-04-18 21:04:41 +01:00
Jeff Young 9c8941e040 Remove a bunch of globals. 2020-04-16 17:34:46 +01:00
Jeff Young 591428b0d9 Remove some problematic global variables.
Fixes https://gitlab.com/kicad/code/kicad/issues/4121
2020-04-05 16:17:04 +01:00
Jeff Young 20c00cbb21 Finish off "busses" -> "buses".
Fixes https://gitlab.com/kicad/code/kicad/issues/4144
2020-04-02 18:27:05 +01:00
Jeff Young cee973dc04 Move ERC error reporting over to the new framework.
Fixes https://gitlab.com/kicad/code/kicad/issues/1989
2020-03-16 11:06:15 +00:00
Jeff Young c68b554c8e Promote PathsAndReferences from wxArrayString to first-class-citizen.
Keeping the data in an un-serialized format greatly simplifies usage,
and should make it more robust.
2020-02-24 23:19:17 +00:00
Jeff Young ea025a35e5 Change KUUID to KIID. 2020-02-21 22:20:42 +00:00
Jon Evans e8e3b4f11e Rename UUID to KUUID to fix MSVC build
Also add another newly-required boost flag
2020-02-20 22:07:17 -05:00
Jeff Young 490f39a671 Remove obsolete code requiring unique sheet names. 2020-02-20 22:56:11 +00:00
Jeff Young 129042f8a6 Convert timestamps to UUIDs. 2020-02-20 21:29:52 +00:00
Jon Evans ac875e26a8 Fix handling of SCH_PINs on multi-unit parts
Fixes https://gitlab.com/kicad/code/kicad/issues/3770
2020-02-04 11:51:29 +00:00
Seth Hillbrand ec8a8ffcbc eeschema: Add connections to sheet pins
Set the sheet pin to be a junction connection point that ensures the
connectivity

Fixes https://gitlab.com/kicad/code/kicad/issues/3852
2020-02-04 04:14:16 -06:00
Seth Hillbrand b8920a9f5a Eeschema: Add protections to eeschema rtree
Prevents items from being mistakenly added to the tree that should not
be tracked in the tree.
2020-01-25 09:32:05 -08:00
Seth Hillbrand bcc68b2dd9 eeschema: Re-load the RTree when we re-cache components
The components are reloaded when libraries change and when loading a
schematic.  The initial load does not contain pins and so bbox hits may
miss elements.

Fixes #3800 | https://gitlab.com/kicad/code/kicad/issues/3800
2020-01-23 10:06:56 -08:00
Seth Hillbrand c2904ce7e9 Fixing drawing order when plotting/printing
This is a partial re-work of a previous commit to the v5 branch
(8f7278e34f) that fixes #368
2020-01-10 16:33:53 -08:00
Seth Hillbrand 6e5e453d0d Replace EESchema DLIST
This moves EESchema DLIST structures to rtree.  These changes are more
fundamental than the pcbnew changes from 9163ac543 888c01d11 d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
2020-01-10 06:37:08 -08:00
Seth Hillbrand d1a05e27a5 eeschema: Correct junction test routine
New v6 can test multiple points not previously considered.  This
corrects the test to ensure that junctions are correctly added when
lines are present.

Fixes #3729 | https://gitlab.com/kicad/code/kicad/issues/3729
2020-01-03 11:46:05 -08:00
Ian McInerney 079423c3cc eeschema: Remove unused include of eeschema_id.h 2020-01-03 16:04:54 +00:00
Wayne Stambaugh aeb3281e27 Convert Schematic Internal Units to 100nm 2019-12-30 18:28:00 +00:00
Wayne Stambaugh 879ec7d8e6 KiCad: fix crash bug when editing symbol library table.
Do not check the connection graph when editing the symbol library table
from KiCad because the connection graph object is no valid when the
schematic editor is not open.

Fixes kicad/code/kicad#3682
2019-12-17 18:42:43 -05:00
Wayne Stambaugh b66ecf141f Eeschema: fix sheet file name case sensitivity test.
Fix overzealous test if the new file name is the same as an existing
file name.

Fix a potential comparison bug due to missing file extension.
2019-12-12 15:36:57 -05:00
Wayne Stambaugh ed025972ab Eeschema: fix crash caused by stale symbol library object pointers.
The new symbol library changes left stale pointers in the connection
graph because the SCH_COMPONENT object pins were not always getting
updated when a new copy of the library symbol was updated.

Force a full update of the connection graph whenever the schematic
library symbol links are refreshed.  This seems like overkill but it
ensures that there a no stale libraries items left in the connection
graph.

Fixes kicad/code/kicad#3658
2019-12-11 18:53:29 -05:00
Wayne Stambaugh 54f066fed7 Implement simple inheritance for library symbols.
This change completely removes the LIB_ALIAS design pattern an replaces
it by allowing LIB_PART objects to inherit from other LIB_PART objects.
The initial implementation only allows for single inheritance and only
supports the mandatory fields in the derived part because that is all
that the current symbol library file format will support.  Once the new
file format is implemented and saving to the old file format is deprecated,
more complex inheritance will be added.  The LIB_ALIAS information saved
in the document files was move into the LIB_PART object.  This change
impacts virtually every part of the schematic and symbol library editor
code so this commit message is woefully incomplete.

REMOVE: Removed the symbol aliases concept from the schematic and symbol
editors and the symbol viewer.

NEW: Replace the symbol alias concept with simple inheritance that allows
a library symbol to be derived from another library symbol.
2019-12-06 11:33:52 -05:00
Seth Hillbrand c6f5df134c Minor speed cleanup
This adjusts iterators to use const reference when only used for
copy.  It also ensures pre-allocation of vectors when size is known
ahead of time.
2019-12-05 14:20:59 -08:00
Wayne Stambaugh 773f45aae3 Eeschema: fix sheet file name case sensitivity bug.
Apparently there are some issues with wxString::CmpNoCase() that was
causing the sheet file name case sensitivity test to incorrectly fail.
Converting the name strings to lower case before comparing resolved
the issue.
2019-11-19 16:06:36 -05:00
Wayne Stambaugh d4cea0f2b7 Eeschema: fix multiple sheet file name bugs.
Add missing check for root sheet when searching sheet hierarchies for
already loaded schematics.  This prevents the root sheet from being
omitted when adding new sheets using the root sheet file name.

CHANGED: Make file name tests case sensitive so that schematic sheet
file names on non-Windows systems can be uses as expected.

Warn users when attempting to use schematic file names that only vary
by case sensitivity that doing so will result in a project that is not
portable to Windows.

Fixes lp:1843415

https://bugs.launchpad.net/kicad/+bug/1843415
2019-11-18 07:59:30 -05:00