Commit Graph

23 Commits

Author SHA1 Message Date
Jeff Young c6a8100d46 Schematic and symbol text boxes.
Also fixes some plot bugs with arcs.

Also moves polygonization of arcs (when required) in plotting code
from 5 degrees to calculated based on ARC_HIGH_DEF.

Fixes https://gitlab.com/kicad/code/kicad/issues/5017
2022-01-28 21:38:15 +00:00
Jeff Young 3409783d9f Break sch_text.h/.cpp into sch_text and sch_label.
Also moves SCH_NETCLASS_FLAG to SCH_DIRECTIVE_LABEL, and remaps Altium
harnesses from SCH_TEXT to SCH_DIRECTIVE_LABEL.
2022-01-28 21:38:15 +00:00
Ola Rinta-Koski 72b69e8d7f File format changes for fonts. 2022-01-08 16:47:45 +00:00
Jeff Young 889970a449 SCH_NETCLASS_FLAGs and SCH_FIELDs for labels.
ADDED: a new label type for netclass flags.
ADDED: the ability to define fields on labels.
2021-12-24 16:13:27 +00:00
Jeff Young f1410f0240 Line styles for PCBNew shapes.
Fixes https://gitlab.com/kicad/code/kicad/issues/2150
2021-12-24 12:36:59 +00:00
Jeff Young 2bc86fa0a8 Shapes for schematic.
ADDED arc, circle and rectangle shapes for schematic.  Shapes support
line styles and fill colors.

CHANGED sheet background color in Edit Text & Graphics Properties to
fill color (and it now affects shapes).

Pushed STROKE_PARAMS down into common and moved all shapes to using it
for stroke descriptions.
2021-12-23 20:36:07 +00:00
Jeff Young ebfbe14185 Persist fields_autoplaced information.
Fixes https://gitlab.com/kicad/code/kicad/issues/8086
2021-04-02 17:08:58 +01:00
Jeff Young 0ba0160da9 Add a PT_NIC pin electrical type and a netlist token for SCH_NO_CONNECT.
ADDED a new pin electrical type "free" for internally unconnected pins.

CHANGED the "unconnected" pin electrical type is now represented by
"no_connect" in files and netlists.  (The legacy syntax is also accepted
in files.)
2021-01-23 00:10:01 +00:00
Wayne Stambaugh 8ff51d8899 Eeschema: add schematic sheet page number.
The groundwork has now been laid for per sheet instance data.  Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.

ADDED: Support for user defined schematic page numbers.
2020-10-19 14:05:45 -04:00
jean-pierre charras 98710e2742 Eeschema, parser: allows using "default" as line style.
It is allowed in Eeschema code, so allow it if found in a .kicad_sch file,
just in case.
However it is not yet in use in .kicad_sch files to avoid breaking previous Kicad versions
2020-10-17 12:39:51 +02:00
Franck Jullien 2fc49045d1 ADDED: eeschema: Add intersheets references function
Add a new function to place intersheets references next to
global labels.
2020-10-01 20:39:32 +00:00
Jeff Young be15053745 Allow back-annotation of differing values and footprints.
Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)

Fixes https://gitlab.com/kicad/code/kicad/issues/5397
2020-09-04 15:21:56 +00:00
Wayne Stambaugh 2078e629c5 Eeschema: allow editing of junction properties diameter and color.
Add missing plot and print changes for the new bus entry properties.

ADDED: Junction properties diameter and color can now be edited.

Fixes: https://gitlab.com/kicad/code/kicad/issues/4593
2020-06-24 13:36:17 -04:00
Wayne Stambaugh 037898f6fb Eeschema: add support for excluding symbols from board.
ADDED: Support for excluding symbols from board during.  This allows for
creating bill of materials only symbols.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/2522
2020-06-10 10:57:28 -04:00
Wayne Stambaugh 77a59fb5d3 Eeschema: add support for excluding symbols from bill of materials.
This provides a method to add symbols that represent footprints on the
board that do not have an associate component such as mounting holes,
fiducials, logos, etc that should be excluded from the bill of materials.
It also prevents those footprints from being removed from the board
accidentally when updating the board from the schematic.

ADDED: Support to exclude schematic symbols from bill of materials
export.
2020-06-03 08:55:13 -04:00
Jeff Young 06dea92bcb Fix issues with Kicad Manager frame and new kicad_sch files.
Fixes https://gitlab.com/kicad/code/kicad/issues/4410
2020-05-12 15:20:17 +01:00
Wayne Stambaugh 91494fc561 Eeschema: add missing bus alias support to new schematic file format.
Fixes https://gitlab.com/kicad/code/kicad/issues/4335
2020-05-06 09:27:01 -04:00
Wayne Stambaugh 0ef97ac486 Eeschema: add missing alternate body style to new schematic file format.
Fixes https://gitlab.com/kicad/code/kicad/issues/4321
2020-05-05 09:15:13 -04:00
Wayne Stambaugh 169f63a6c0 Eeschema: make schematic sharing truly safe across all designs.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects.  It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic).  This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet.  This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references.  It also allows the root schematic from one project
to be uses as a sub-sheet in another project.

When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs.  This is done to ensure there
are no sheet path instance clashes between projects.  That being said,
there are no checks for this.  It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh c9b00e3898 Eeschema: minor s-expression file format improvements.
I could not find a reasonable solution to the mandatory field canonical
name issue so field indices are back in play as much as I did not want
to use them.  They really only have meaning for the mandatory fields.
For all other fields, the index number is meaningless and the field name
is the primary means for searching.

Fix a broken field size bug in the symbol library formatter.
2020-04-06 22:47:42 +00:00
Wayne Stambaugh 2f682b6c5f Eeschema: implement s-expression schematic file format parser.
Fix a few issues with the s-expression schematic file formatter.
2020-04-06 22:47:42 +00:00
Wayne Stambaugh 7dc64f08b7 Eeschema: implement s-expression schematic file formatter.
Please note that the symbol cache is not embedded in the schematic file
to allow for round robin testing with the existing file format.  Once
the parser round robin testing is complete, the symbol cache will be
embedded in the schematic file.
2020-03-16 09:05:16 -04:00
Renamed from eeschema/symbol_lib.keywords (Browse further)