legacy plugin: better compatibility with old brd files (current track width and current vias size, stored in SETUP section, were not read from file and incorrectly set)
The plan goes like this:
- eeschema still uses int in decidegrees
- all the other things internally use double in decidegrees (or radians
in temporaries)
- in pcbnew UI the unit is *still* int in decidegrees
The idea is to have better precision everywhere while keeping the user with int i
angles. Hopefully, if a fractional angle doesn't come in from the outside, everything
should *look* like an integer angle (unless I forgot something and it broke)
When the time comes, simply updating the UI for allowing doubles from the user should
be enough to get arbitrary angles in pcbnew.
- Removed spurious int casts (these are truncated anyway and will break
doubles)
- Applied the Distance, GetLineLength, EuclideanNorm, DEG2RAD, RAD2DEG
ArcTangente and NORMALIZE* functions where possible
- ArcTangente now returns double and handles the 0,0 case like atan2, so
it's no longer necessary to check for it before calling
- Small functions in trigo moved as inline
* Complete encapsulation of the MODULE class.
* Complete encapsulation of the EDA_TEXT class.
* Encapsulate most of the ZONE_CONTAINER class.
* Add pcbcommon library as a dependency for reSWIGging the scripting
support. This should cover most dependency cases.