The fractional part of Altium schematic units is an integer number of
1/10000 mil segments, which is 2.54 nm. The internal unit of eeschema
is 10 nm, so each fractional unit in Altium is 0.254 base eeschema
units. To be consistent with
cf33cfcad1
we round to the nearest 10nm for each element
Fixes https://gitlab.com/kicad/code/kicad/issues/11742
The original decision to escape the legacy symbol library names results
in them being escaped every time they are opened which cause the curly
braces '}' from the original escaping to be escaped on subsequent
openings. This resulted in the symbol library names in the rescue
library not matching the library ID in the schematic.
This fix is likely to have other corner case bugs given the potential
for escaped characters in legacy symbol libraries. Given that we now
have escaped rescue libraries in play, removing the escaping will only
result in more issues so we will have to fix the corner cases as we go.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11563
Prior to fixing the schematic file change churn do to instance data
changing to the last selected sheet instance, the symbol instance data
was set rather than empty. This change allows for users to set the
default instance data which is used for every new instance of the
schematic.
ADDED: Default schematic symbol instance data (unit and reference, value,
and footprint fields) can be set to be used as the default settings
for all new instances of the schematic.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11113
In symbols, a polyline descr is already a true polyline / polygon descr.
In schematic, a polyline descr was restricted to only 2 points (a line).
A true polyline / polygon descr is now allowed in schematic that support already
polygons.
For compatibility reason, a 2 points polygon (SCH_SHAPE) is converted to a SCH_LINE.
Previously, coordinates were clamped to +- 60 inches. It makes no sense to
clamp them at plotter level: max cooed depends on the editor (schematic/board...)
Rename MAX_PAGE_SIZE_MILS to MAX_PAGE_SIZE_EESCHEMA_MILS and use it only for Eeschema.
Fixes#11196https://gitlab.com/kicad/code/kicad/issues/11196
The previous solution cleared all of the fields and force the unit setting
to unit one which would have less than desirable effects when reusing a
schematic in another project. This solution forces all of the instance
settings to the first sheet instance of the current project to prevent file
change churn when changing shared sheets in the current project.
This will not prevent shared schematic file changes when the first sheet
instance data differs between projects.
Arcs can be altered by the process of changing from on-disk
representation to in-memory representation. Saving back to disk without
modifying the arc should not modify the calculated values.
This stores a copy of the on-disk representation that is only used to
save back to disk in the event that the arc is not modified during
editing.
Fixes https://gitlab.com/kicad/code/kicad/issues/10442
Removes the ability to hide symbol units in file formats. This was
mostly the case for a while but there remained corner cases where we
left a default/hidden option
Fixes https://gitlab.com/kicad/code/kicad/issues/10888
KiCad has stricter requirements for what consititutes an annotated
symbol. This checks for and corrects annotations that begin with '#',
do not begin with a non-numeric character or do not end with a number
gcc doesn't need it and computes during compile regardless, but experimenting in godbolt, both clang and MSVC actually do need it or else it's partially computed at runtime
Also fixes some plot bugs with arcs.
Also moves polygonization of arcs (when required) in plotting code
from 5 degrees to calculated based on ARC_HIGH_DEF.
Fixes https://gitlab.com/kicad/code/kicad/issues/5017