At the moment, units are stored in the instance data, so when loading
the file, all symbols will have bbox for the first unit. After calling
`UpdateUnit()`, we need to recache the rtree bounding boxes to get
correct hit tests
Fixes https://gitlab.com/kicad/code/kicad/issues/11681
Prior to fixing the schematic file change churn do to instance data
changing to the last selected sheet instance, the symbol instance data
was set rather than empty. This change allows for users to set the
default instance data which is used for every new instance of the
schematic.
ADDED: Default schematic symbol instance data (unit and reference, value,
and footprint fields) can be set to be used as the default settings
for all new instances of the schematic.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11113
Also fixes some plot bugs with arcs.
Also moves polygonization of arcs (when required) in plotting code
from 5 degrees to calculated based on ARC_HIGH_DEF.
Fixes https://gitlab.com/kicad/code/kicad/issues/5017
Always use full sheet paths when storing sheet instances. Partial sheet
paths cannot be full resolved resulting in lost page numbers when renaming
sheet file name.
Fixes#9782
Remove duplicate instance data saved in both root SCH_SCREEN and SCH_SHEET
objects that was causing them to be out of sync. All sheet instance data
is stored in the SCH_SHEET object itself and rebuilt on the fly so it is
always current.
Remove Get/SetPageNumber from SCH_SHEET_PATH object so it doesn't obfuscate
where the actual sheet page number information exists.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/9782
Found via `codespell -q 3 -S *.po,./thirdparty -L aactual,acount,aline,alocation,alog,anormal,anumber,aother,apoints,aparent,aray,dout,einstance,modul,ot,overide,serie,te,,tesselate,tesselator,tht`
This was leaking windows headers and partial wx headers to 1084 compilation units......
This also means math/util.h is leaking to 1084 compilation units which seems a bit high too.
Differentiates better between the EDA_ITEM IsModified(), referring to
items themselves changing and the EDA_SCREEN IsContentModified(),
referring to whether we have made any unsaved changes.
Save sheet and symbol instance information to the clipboard on copy
Load sheet and symbol instance information from the clipboard on paste
and renumber page numbers after loading.
Correctly handle pasting in a multiple hierarchy by ensuring symbol and
sheet instances are updated for all instances of the destination sheet.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/8207
Avoid code duplication by moving all common code to a new function
SCH_SEXPR_PLUGIN::saveInstances
Also fixes a bug that was resulting in footprint and value information
not being saved for subsheets that were root sheets in a different
project.
- new function SCH_SHEET_LIST::SortByPageNumbers() which uses SCH_SHEET::ComparePageNum for the sorting algorithm
- SortByPageNumbers() is called after every call to BuildSheetList()
1) Generalize SCH_ITEM owners (SCH_COMPONENT, SCH_SHEET, and now
SCH_GLOBALLABEL)
2) Generalize hypertext items
3) Use SCH_FIELD autoplace infrastructure for placing intersheet
references
4) Use textVar infrastructure for buildin intersheet references.
As an important side-effect this also fixes the undo issues with
intersheet refs.
The groundwork has now been laid for per sheet instance data. Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.
ADDED: Support for user defined schematic page numbers.