Commit Graph

150 Commits

Author SHA1 Message Date
Wayne Stambaugh 7a00e01b3e Eeschema: fix false positive library symbol changed ERC errors.
This fix required sorting all of the LIB_PART draw items to ensure
accurate comparison between the symbols stored in the schematic and the
original library symbols.  This has a noticeable impact on symbol library
load performance.  It may also cause significant changes the next time
the library is saved due to changes in the draw item sorting.  Hashing
may be a better solution here but this addressed the immediate problem.

A skeleton method SCH_SCREEN::SwapSymbolLinks() was added because there
is most likely an issue with orphaned symbols in the schematic library
symbol cache during undo/redo operations.  More testing is required to
verify this.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/7263
2021-03-04 17:59:24 -05:00
WhiteChairFromIkea ff23f4324a Do not hardcode altium file extension length 2021-03-04 12:20:40 +00:00
Ian McInerney 908de37e7c Don't hardcode the file extensions where possible 2021-03-03 01:13:59 +00:00
WhiteChairFromIkea 2c289b3f35 Check for ".SchDoc" before replacing to ".kicad_sch" for subsheet 2021-03-02 22:30:08 +00:00
WhiteChairFromIkea f83b9236ac Formatting 2021-03-02 22:30:08 +00:00
WhiteChairFromIkea b98602583c Remove "SchDoc" and use "kicad_sch" instead for subsheet names 2021-03-02 22:30:08 +00:00
WhiteChairFromIkea 042ea9761c Revert "Import footprint to symbols. Subsheet is name is prepended to footprint name,..."
This reverts commit 8aa4faa4ce24adc6310223952e8b5773ce245778
2021-03-02 22:30:08 +00:00
WhiteChairFromIkea 292aff48fd Import footprint to symbols. Subsheet is name is prepended to footprint name, which is probably NOT OK when syncing with PCB. 2021-03-02 22:30:08 +00:00
Jeff Young 8a33542bcd SCH_COMPONENT::GetField() expects a vector index, not a field id.
Check this at compile time.  Callers wanting to use an index now must
use SCH_COMPONENT::GetFields()[i] instead.

Fixes https://gitlab.com/kicad/code/kicad/issues/7757
2021-02-28 15:10:37 +00:00
Roberto Fernandez Bautista 76ef98339d CADSTAR PCB Archive Importer: Re-write loading of power symbols
Ensure all each power symbol is unique for each net name even
if it uses the same graphical symbol.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7722
2021-02-26 19:32:44 +00:00
Wayne Stambaugh 1786ae8773 Eeschema: use symbol nomenclature for object file naming. 2021-02-24 08:48:02 -05:00
Jeff Young a3b9e8ddb4 Round 2 of Worksheet -> Drawing Sheet. 2021-02-23 11:57:44 +00:00
Roberto Fernandez Bautista ccbc0f73cc CADSTAR Schematic Archive Importer: Fix Coordinate Rounding error
Rewrite of the calculation to convert CADSTAR to KiCad coordinates,
rounding half way cases away from zero.
Use integer division instead of double, to ensure precision.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista 842a930ced CADSTAR Schematic Archive Importer: Autoplace fields when adding sheet
Makes the sheets look a little bit better when there is no block name
in the original CADSTAR design.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista 7b5cf955af CADSTAR Schematic Archive Importer: Visible fields to calculate BBOX
- Ensures page size is calculated correctly
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista 5acdf1ddb1 CADSTAR Schematic Archive Importer: Align to original grid
Previous assumption of 100mil grid in CADSTAR schematic designs has
been proven to be incorrect. Let's use the "working grid" in the
original design instead.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista c98106ebcf CADSTAR Schematic Archive Importer: Parse TESTPOINT
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7574
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista 09ebfcd650 CADSTAR Importer: Fix Code Style
- Rename member variable names to use the 'm_' prefix
- Rename a few object types that clashed with KiCad object names, such
  as BOARD and SCHEMATIC, to avoid the use of '::' to access the KiCad
  objects.
- Remove some unused code.
2021-02-22 13:24:00 +00:00
Jeff Young 2a7e60960a Use standard mirror icons & terminology.
Also use standard group icons.

Also put both (and rotate commands) in toolbar.

Fixes https://gitlab.com/kicad/code/kicad/issues/7504
2021-02-16 21:11:36 +00:00
Wayne Stambaugh 114dceec2e Eeschema: Eagle schematic plugin parser improvements.
* Complete drawing of sheet border/title block symbol.
2021-02-16 09:33:15 -05:00
Wayne Stambaugh 089b7afacf Eeschema: Eagle schematic plugin parser improvements.
* Fix multi line text alignment.
* Parse schematic frame objects and convert them to lines.
* Make implicit global labels normal size so they can easily be seen.
* Move sheet fields to a more sensible position.
* Parse schematic symbol instances before wires so that the implicit power
  connections can properly be tested.  This will be used at a later time.
* Scale label text size down to allow for differences in label offset and
  graphical items.
2021-02-15 16:44:58 -05:00
Seth Hillbrand 8745691da3 Toggle LOCALE_IO before re-caching
cacheLib() can cause a re-load event, which requires the C-locale.
LOCALE_IO needs to be set before this event to prevent mistaken ','/'.'
mixups

Fixes https://gitlab.com/kicad/code/kicad/issues/6434
2021-02-15 09:10:21 -08:00
Seth Hillbrand cea9e1b62c Remove Eagle workaround for stacked NC pins
We no longer put stacked NC pins in the same net, so we do not require
this hack.
2021-02-11 16:47:21 -08:00
Roberto Fernandez Bautista 7c06bdbd2e CADSTAR Schematic Archive Importer: Fix parsing of TERMINAL_SHAPE
TRIANGLE shape and a few others do not have a "right length",
only a "length".
Fixes the error "Missing Parameter ‘2’ in ‘TRIANGLE’".
2021-02-10 18:49:21 +00:00
Roberto Fernandez Bautista 80d8974f87 CADSTAR Archive Importer: Fix loading of non-cadstar font text sizes
Non-cadstar fonts use a width of 0.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista 49bf957c48 CADSTAR Schematic Archive Importer: Fix positioning of global labels
Previous calculation did not take into account rotation of the labels
when calculating the final position.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista 0841f3ae25 CADSTAR Schematic Archive Importer: Fix wires (Implied connections)
There is an implied connection between elements in a net even though
there might not be a graphical connection in the file.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista 8add7a880d CADSTAR Schematic Archive Importer: Fix positioning and margins
Fix calculation of sheet bounding box and sheet margins with the aim
of matching CADSTAR pdf output as closely as possible.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista cb90a4b7e6 CADSTAR Schematic Archive Importer: Handle Pin Swaps
Each schematic symbol instance can have pin numbers that diverge from
the pin number definitions in the library
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista 4ea487936b CADSTAR Schematic Archive Importer: Simplify symbol library name 2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista 4dc264175a CADSTAR Schematic Archive Importer: Symbol name is case insensitive
Fixes an issue on some designs that would not be able to find the
symbol definition referenced by the part due to different
capitalisation of the symbol name in the part definition and
the symbol definition.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista 914ae001b5 CADSTAR Schematic Archive Importer: Load pin types
Default to passive if undefined
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista f530b12c31 CADSTAR Schematic Archive Importer: Handle undefined pin number in part
Use terminal pin number (i.e. from the symbol definition) when the pin
number is undefined in the part.
This fixes a bug that resulted in symbols with "0" as the pin numbers.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista cc27c31ab0 CADSTAR Schematic Archive Importer: Import common fields visibilities
Import field visibilities for Ref, Value and Part Name
Also fix incorrect loading of designator from previous commit
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista 297ff282f1 CADSTAR Importer: Update copyright years and remove white spaces 2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista bb6fee531e CADSTAR Schematic Archive Importer: Correctly load symbol instances
Previous implementation was not loading all fields defined in the
library.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista b0051c07cb CADSTAR Schematic Archive Importer: Load all fields in symbols
- Load Fields in the library items as well as schematic instances
- Remove invalid characters (e.g. '\n', '\t', '\r') in fields
- Load footprint field (assume that the footprint library name
  is the same as the filename of the schematic)
2021-02-10 18:49:20 +00:00
Wayne Stambaugh c11ded24cd Add instrumentation to track down local issues in symbol library file code. 2021-02-01 12:57:16 -05:00
Jeff Young dfc6070178 Unify schematic file version checking with PCBNew.
This also makes sure that the user gets a warning before saving over
an older s-expr format.  While that won't always be wanted, it's now
in the infobar (like in PCBNew), so it's not too onerous.§

Fixes https://gitlab.com/kicad/code/kicad/issues/7347
2021-01-31 17:28:14 +00:00
Thomas Pointhuber 619e128536 altium: Fix #6194 by no longer mirroring schematic text. Furthermore improve value parsing. 2021-01-30 15:44:32 +01:00
Jeff Young 540dd11b58 Use the file version when reading lib symbols from schematic file. 2021-01-28 21:31:33 +00:00
Jeff Young ff7742c6b8 File naming and include cleanup. 2021-01-28 11:35:18 +00:00
Jeff Young 0967f8fc78 Fix typo. 2021-01-26 23:17:30 +00:00
Jeff Young 06f85471a4 Fix copy/paste error. 2021-01-26 19:01:31 +00:00
david-beinder 4bcd56b1f6 Always include unit number when copying to clipboard
Fixes https://gitlab.com/kicad/code/kicad/issues/5898 (A)
2021-01-26 18:12:49 +00:00
Wayne Stambaugh 4619d5e112 Fix more broken Doxygen comment specifiers. 2021-01-26 12:17:52 -05:00
Jeff Young 3702f2e0a9 Add uuid r/w for sch pins, text, wires, etc.
Fixes https://gitlab.com/kicad/code/kicad/issues/7269
2021-01-26 10:56:19 +00:00
Jeff Young 0ba0160da9 Add a PT_NIC pin electrical type and a netlist token for SCH_NO_CONNECT.
ADDED a new pin electrical type "free" for internally unconnected pins.

CHANGED the "unconnected" pin electrical type is now represented by
"no_connect" in files and netlists.  (The legacy syntax is also accepted
in files.)
2021-01-23 00:10:01 +00:00
Roberto Fernandez Bautista 42cbcf7ef4 Don't allow empty page numbers
Fixes https://gitlab.com/kicad/code/kicad/-/issues/6698
2021-01-22 14:02:34 +00:00
Roberto Fernandez Bautista b168b74919 CADSTAR Archive Importer: Fix position of multiline text with NO_ALIGNMENT in CADSTAR 2020-12-30 18:53:43 +00:00