Use the legacy plugin schematic loader in the sheet edit and append
schematic code paths.
Check for fully qualified LIB_ID objects (must have library nickname)
when loading existing schematics when edit sheets.
Rewrite append schematic feature to handle import issues rather than
change the name and file name of all of the sheets in the imported
schematic. This includes the following:
- Load the schematic into a temporary SCH_SHEET object.
- Make sure the imported schematic does not cause any hierarchy
recursion issues.
- Verify the imported schematic uses fully qualified #LIB_ID objects
(symbol library table).
- Check to see if any symbol libraries need to be added to the current
project's symbol library table. This includes:
- Check if the symbol library already exists in the project or global
symbol library table.
- Convert symbol library URLS that use the ${KIPRJMOD} environment
variable to absolute paths. ${KIPRJMOD} will not be the same for
this project.
- Check for duplicate symbol library nicknames and change the new symbol
library nickname to prevent library name clashes.
- Update all schematic symbol LIB_ID object library nicknames when the
library nickname was changed to prevent clashes.
- Check for duplicate sheet names which is illegal and automatically
rename any duplicate sheets in the imported schematic.
- Clear all of the annotation in the imported schematic to prevent
clashes.
- Append the objects from the temporary sheet to the current page.
- Replace any duplicate time stamps.
- Refresh the symbol library links.
Add support code to SCH_SCREEN object to assist with schematic import.
Doxygen comment cleaning.
Fixes lp:1731760
https://bugs.launchpad.net/kicad/+bug/1731760
The GTK+ file dialog is case sensitive however it does support regular
expressions. Most of the file dialog wildcards are lower case so only
files with the lower case extensions will show up in the file dialog.
This code adds a method to convert file extensions of any case to the
appropriate (sch -> [sS][cC][hH]) regular expression on GTK+ builds so
all file extension case combinations will show up in the file dialog.
A note to developers: make sure to add a file extension when setting
when setting the default file argument. If you do don't set an
extension, the GTK+ file dialog will happily append the regular
expression as the file extension which is surely not what you want.
There are still a few known places (mostly gerbview) where there are
some complex wildcard code that has not been converted.
Fixes lp:1720542
https://bugs.launchpad.net/kicad/+bug/1720542
Refactor rescue objects so that they can support derivation.
Factor out legacy rescuer code to perform legacy project rescues.
Create new symbol library table rescuer for rescuing symbol library table
based projects.
Perform the correct rescue type on project load.
Add symbol library table remapping support to the tools menu for run on
demand as applicable.
Add flag to SCH_SCREENS::UpdateSymbolLinks() to allow forcing the symbol
link updates when the library modification hash has not changed.
Check the if the schematic being loaded has been remapped (no symbol
library table nicknames defined) and remap accordingly.
Fix issues when resolving the library symbol links in the schematic
symbols.
Add cache library fallback when resolving symbols that cannot be
remapped.
Add remap complete message to remap dialog.
Add HasLibrary() helper to LIB_TABLE_BASE.
Fix issues when loading library symbols using symbol library table.
Add hashing function to symbol library table.
Improve the symbol panel message to warn user when cache library is
used to resolve symbol.
- Also makes the project and file import functions filetype dependent.
- The change from IO_MGR::KICAD to IO_MGR::KICAD_SEXP removes a conflict from a compile definition for KICAD when compiling kicad/import_project.cpp
- !! Eeschema uses Eagle plugin for loading schematics (i.e. it does not
use KiCad format anymore)
- Fixed build errors
- Fixed a few crashes
- Code formatting
Add loading symbol library table code to schematic PROJECT object.
Fix minor issues with loading global symbol library table.
Add default symbol library path environment variable to the environment
variable list and change the variable name to KICAD_SYMBOL_DIR.
Add code to SCH_SCREENS to test if all library nicknames of the symbol
library IDs are empty.
Remove unnecessary KICAD_USE_SCH_IO_MANAGER build option.
Fix if statement logic to ensure the unit number is never set to zero.
Add logic to the legacy schematic plugin to automatically convert any
schematic files that have components with a unit setting of zero. Set
the schematic modified flag so that the user will be notified of a
changed schematic.
Add a user warning when the schematic parser fixes the bug and sets
the file modified flag.
Fixes lp:1677282
https://bugs.launchpad.net/kicad/+bug/1677282
Only the root sheet symbol library links were being updated when the
schematic was loaded so changed call to update all sheets.
Fixes lp:1670079
https://bugs.launchpad.net/kicad/+bug/1670079
When Eeschema is relaunched from KiCad, the symbol libraries were always
reloaded which isn't necessary as they are maintained by the kiface project
object until the project is changed.
Fix minor title capitalization in symbol library progress dialog.
Move adding LIB_PART to library until the part is fully parse. The problem
was unique_ptr was cleaning up the part when an exception was thrown during
parsing causing a double free when the cache was deleted.
Add missing try/catch block when loading the cache library during an append
schematic operation.
Fixes lp:1663869
https://bugs.launchpad.net/kicad/+bug/1663869
Add SCH_PLUGIN object to PART_LIB object.
Convert all PART_LIB I/O to use SCH_PLUGIN.
Remove library caching from PART_LIB and use caching provided by SCH_PLUGIN.
Add support to use PROPERTIES for buffering and document file write control
instead of adding code the SCH_PLUGIN object in the SCH_LEGACY_PLUGIN that
will not be required when the new file formats are implemented.
Add buffering to SCH_LEGACY_PLUGIN to prevent cache from writing file on
every change to library. This is to prevent the cache library from being
written every time a new symbol is added.
Add option to not save library document file when saving library. This is
primarily used by the cache library write code.
Move symbol library write code out of LIB_PART and into SCH_LEGACY_PLUGIN.
Add exception handling where LIB_PART caught the exception and returned
an error status.
Remove KICAD_SCH_IO_MANAGER build option as it is no longer optional.
* Add SCH_PLUGIN::Save() for current file format and code for saving all
SCH_XXX objects.
* Add function to SCH_FIELD to get the position of the field in the component
not the position added to the component position which is what GetPosition()
does. This was required because saving the component field expects position
of the field sans the position of the component.
* Remove public members from BITMAP_BASE object and fix all associated
code.
* Fix the never ending coding policy violations found making these changes.
* Create a new dummy root sheet and screen when the schematic fails to load
which was causing Eeschema to crash.
* Remove conversion from UTF8 to wxString left over from a previous change
which hopefully will fix an OSX build error.
* Fix parsing of text objects to handle version 1 schematic files.
* Fix parsing of component fields to handle version 1 schematic files.
* Don't throw a parse error when a version 1 schematic file doesn't end with
$EndSCHEMATC.
* Factor out PROPERTIES object from the PCB plugin code and move it into
common so it can be used by both the Pcbnew and Eeschema plugins.
* Add schematic I/O plugin manager for loading and saving schematic and
component library files.
* Add initial attempt at a parser for current schematic file format. This
parser will be infinitely more strict than the current parser which is very
forgiving in what it parses.
* Make minor changes to the base bitmap class to support the new parser.
* Add find root sheet support to sheet object to allow fetching the root
sheet from any sheet in the stack.
* Ensure proper SCH_SHEET object page numbering which caused annotation to
calculate incorrect reference designators when annotating by using page offsets.
* Added SetPageNumbers to SCH_SHEET for setting sheet page numbers after
schematic is loaded.
* Make SCH_SHEET parent the SCH_SHEET object that loaded it. This preserves
the hierarchy when the schematic is loaded.
* Add function to SCH_SHEET to find the root sheet from any sheet in the
hierarchy.
* Add functions to SCH_SHEET to create the path and human readable paths for
any sheet without relying on the external SCH_SHEET_PATH object.
* Remove function LocatePathOfScreen from SCH_SHEET since it was not used
anywhere.
* Add human readable path to message panel information for SCH_SHEET.
* Set the name of the root sheet to "root" instead of the default generated
when a new SCH_SHEET is created.
* Set the empty sheet name and file name to "root" and "noname.sch" when
Eeschema is opened with no schematic.
* When no item is at the current position on a left mouse click, show the
current sheet information in the message panel.
* Add less than operator for sorting SCH_SHEET objects by path length and
time stamps when the path lengths are the same.
- Slightly change the info text in the dialog. Add a definition of exactly what it means to "rescue" a component.
- Reload the project libraries when a project is opened, even if kicad is already running and the same project is open (to be sure the lib cache is up to date).
- Set the Modified flag on cancel, because a change has indeed been made (choosing not to rescue is equivalent to updating the components)
* auto-save was broken for all sub sheets with are in a sub-directory of the project directory. (reason wxFileName::Normalize(), used to create the absolute path has issues with filenames starting by '$', perhaps due to env var which also start by $). the auto-save prefix is modified ( now AUTOSAVE_PREFIX_FILENAME which defines "_save_" ) and defined only once.
* auto-save files from sub-sheets were not found due to the fact the path was not set (fixed by Blair Bonnet's patch)
* Add code to test if any of the components in the schematic cache have been changed
in the component libraries.
* Prompt user to accept or reject components when changes are found.
* If the user chooses to use the components in the cache, create a new library with the old
components and add it to the beginning of the component library list so the schematic will
not be changed.
* Create dialogs to handle user feedback and status.
* move not shared files (sch_item_struct.*, sch_base_frame.h) to eeschema;
* move wxEeschemaStruct.h to eeschema and rename it schframe.h to be consistent with the other corresponding file name schframe.cpp;
* remove few not needed #include
*) When kicad.exe closes a project, close any open KIFACEs so that they cannot
get disassociated from their true PROJECT.
*) Allow loading eeschema library editor from kicad.exe
*) Allow loading pcbnew library editor from kicad.exe
*) Rename LIB_COMPONENT to LIB_PART.
*) Add class PART_LIBS, and PART_LIB.
*) Make PART_LIBS non-global, i.e. PROJECT specific.
*) Implement "data on demand" for PART_LIBS
*) Implement "data on demand" for schematic SEARCH_STACK.
*) Use RSTRINGs to retain eeschema editor's notion of last library and part being edited.
*) Get rid of library search on every SCH_COMPONENT::Draw() call, instead use
a weak pointer.
*) Remove all chdir() calls so projects don't need to be CWD.
*) Romove APPEND support from OpenProjectFiles().
*) Make OpenProjectFiles() robust, even for creating new projects.
*) Load EESCHEMA colors in the KIWAY::OnKiwayStart() rather in window open,
and save them in the .eeschema config file, not in the project file.
*) Fix bug with wxDir() while accessing protected dirs in kicad.exe
*) Consolidate template copying into PROJECT class, not in kicad.exe source.
*) Generally untangle eeschema, making its libraries not global but rather
held in the PROJECT.
Also fix incorrect backannotation when footprint names contain spaces (put spaces in names is always a bad idea)
* Fix minor Bug #1349058 Choose component dialog: Search field loses focus after entering a character and internationalize the dialog.
* Fix a subtle bug which prevent eeschema to read the project config file when launched from kicad manager, and when kicad.pro is not found.