- Move PLUGIN_FILE_DESC to common.
- SCH_PLUGIN: rename Load -> LoadSchematicFile, Save -> SaveSchematicFile.
- Use PLUGIN_FILE_DESC and CanRead* in schematic plugins.
- Return none/unknown types from Find/GuessPluginType functions.
- Iterate over file types for file wildcards.
- Clean-up header checking in IO plugins.
- Use PCB plugin list in IO_MGR::GuessPluginTypeFromLibPath.
Don't use the value field when adding Eagle part attributes to a symbol.
This issue was cause by using a mandatory symbol field ID instead of
using the next available field ID when adding new fields to as symbol.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13468
Earlier commit moved variable substition earlier (in loadSymbolText())
so we didn't have the correct info later when we tried to do the
special processing on it.
Fixes https://gitlab.com/kicad/code/kicad/issues/13541
Eagle schematics do not show the value field when it's not defined or
when not package (footprint) is defined for the symbol which is the
case for power symbols. Don't show the value field in KiCad to bring
the view more in line with what Eagle displays.
Inspired by Stefan's merge request #13433.
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/13433
This will make it possible to maintain sheet instance information when
copying and pasting from any sheet other that the root sheet of a
project.
Setting and getting sheet page numbers must now be performed using a
sheet path. This was done to ensure that the instance paths were not
getting changed unexpectedly from different code paths.
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Added project name to instance data to improve the readability of the
schematic file format. It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472