Ian McInerney
ecd9bf696e
Be consistent about using nullptr instead of 0
...
0 can be too easily overloaded into an int, so ensure we use nullptr
when we mean pointers.
2021-04-22 22:20:34 +01:00
Ian McInerney
ae91042544
Implement thread safety for symbol loading routines
...
These functions can be called from any thread of the library
loader, so we need to ensure we have some thread safety with them.
2021-04-18 18:39:46 +01:00
jean-pierre charras
31e9895a1a
Fix a minor compil warning
2021-04-15 19:49:41 +02:00
Roberto Fernandez Bautista
45409ec314
CADSTAR Schematic: Fix orientation of symbol fields
2021-04-12 20:25:04 +01:00
Roberto Fernandez Bautista
9148542219
CADSTAR Schematic: Fix Text Positioning within Symbols
2021-04-12 20:25:03 +01:00
Thomas Pointhuber
f13eb13b9a
altium: import images from SchDoc
2021-04-10 21:52:37 +02:00
Wayne Stambaugh
2b86b34124
Eeschema: split out SCH_SHEET_PIN declarations into separate header.
2021-04-06 17:15:49 -04:00
Wayne Stambaugh
df186a2049
Eeschema: fix root sheet UUID changing in project file.
...
This change is a bit more invasive than the description above would
suggest. UUIDs have been added to all schematics. For now, it's only
useful to the root schematic so that the UUID in the project file does
not change every time the project file is save. In the future, it may
be useful to store and check the schematic UUIDs against the one's saved
in the project file.
Fixes https://gitlab.com/kicad/code/kicad/issues/7763
2021-04-06 14:28:01 -04:00
Roberto Fernandez Bautista
d041578150
CADSTAR Schematic: Fix import of text alignment
...
Ensure that the text alignment applied to text objects corresponds to
valid text alignments that can be set within eeschema
Fixes https://gitlab.com/kicad/code/kicad/-/issues/8090
2021-04-05 20:15:08 +01:00
Carsten Schoenert
cb17c9f3dd
Typo fix: Correct various misspelled words
...
agressive -> aggressive
decription -> description
miscellanous-> miscellaneous
rectange -> rectangle
Unkown -> Unknown
2021-04-03 13:39:50 +00:00
Jeff Young
ebfbe14185
Persist fields_autoplaced information.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/8086
2021-04-02 17:08:58 +01:00
jean-pierre charras
655a696589
fix compil issue
2021-04-01 11:36:30 +02:00
jean-pierre charras
6499b5f296
Eeschema: protect lib symbols against duplicate field names.
...
If a field name is already in use, try to rename the new field name
(adding the suffix "_1" or "_2" or ... )
This is especially critical when a non mandatory field has the same name as
a mandatory field (was crashing before)
Fixes #8081
https://gitlab.com/kicad/code/kicad/issues/8081
2021-04-01 11:27:14 +02:00
Jeff Young
2ad69fc56b
Move importers from wxLog to REPORTER.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/6389
2021-03-31 22:54:30 +01:00
Roberto Fernandez Bautista
c5e4220b5b
CADSTAR Schematic: Fix duplicate pins
...
Fixes a bug that was causing duplicate pins to be loaded
(one on top of the other) for all symbols.
2021-03-30 13:03:56 +00:00
Roberto Fernandez Bautista
1629b038e1
CADSTAR Schematic: Fix loading of symbol instances differing from part
...
The previous assumption was that a part definition would always hold
the information about the symbol. However some designs have symbol
instances that refer to a different symbol definition than that
specified in the part.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7808
2021-03-30 13:03:56 +00:00
Roberto Fernandez Bautista
e6c7ddc271
CADSTAR Schematic: Fix loading of symbol attributes
...
Fixes an issue that resulted in incorrect field values being loaded
2021-03-30 13:03:56 +00:00
Roberto Fernandez Bautista
51db9cfcef
CADSTAR Schematic: Text Loading improvements
2021-03-30 13:03:56 +00:00
Jeff Young
a0a5e93782
Remove m_props from symbol library plugins. It's not thread-safe.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/8035
2021-03-26 21:57:32 +00:00
Jeff Young
3d6c05b210
Apply symbol field id fixup logic to lib parts.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/7903
2021-03-26 21:57:32 +00:00
Roberto Fernandez Bautista
e0d2724f68
CADSTAR Schematic: Increase "tiny" bus labels to 0.4mm text size
...
Also fix incorrect label orientation
2021-03-25 19:10:49 +00:00
Roberto Fernandez Bautista
6494e0bf25
CADSTAR Schematic: Fix orientation of net labels and sheet pins
2021-03-25 17:50:33 +00:00
Roberto Fernandez Bautista
5a74fb9bb1
CADSTAR Schematic: Ensure connectivity with tiny labels at Bus Entries
...
Always add a label at bus terminals to ensure connectivity. The original
design might already have a bus terminal with a given location.
If the original design does not have a label, just make it very small
to keep connectivity but make the design look visually similar to
the original.
2021-03-25 17:50:33 +00:00
Wayne Stambaugh
cfaca0e4bb
Revert "Eeschema: remove all legacy schematic and symbol library save code."
...
This reverts commit 9c19c2306e
.
Unfortunately writing legacy symbols libraries can never be removed because
of the symbol rescue feature. :(
Fixes https://gitlab.com/kicad/code/kicad/issues/7986
2021-03-22 08:19:47 -04:00
Roberto Fernandez Bautista
a0889705e7
EAGLE and Altium SCH importers: UpdateSymbolLinks after import
...
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7687
2021-03-21 20:13:20 +00:00
Thomas Pointhuber
d9229697d8
altium: special string override map should be case-insensitive
...
This only fixes overrides where we explicitly map an override. Wrongly written variables pointing to fields are not corrected by this.
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/6256
2021-03-20 20:42:25 +01:00
Wayne Stambaugh
9c19c2306e
Eeschema: remove all legacy schematic and symbol library save code.
...
Legacy schematic and symbol library saving is officially deprecated.
2021-03-20 13:29:44 -04:00
Jon Evans
c04e19f9ac
Include optimization: move some things from common.h to point-of-use
2021-03-20 12:09:18 -04:00
Thomas Pointhuber
4482b3baba
altium: Handle special strings and convert them into KiCad variables. Use Comment for VALUE.
...
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/6256
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/7736
2021-03-14 16:40:36 +01:00
Jeff Young
2a9186d9e9
Don't re-use FieldIDs when assigning ids on save.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/7849
2021-03-09 15:09:31 +00:00
Dominik Wernberger
e2aa7be4b3
Added a lot of consts and refactored a few lines
2021-03-08 12:49:48 -08:00
Wayne Stambaugh
7a00e01b3e
Eeschema: fix false positive library symbol changed ERC errors.
...
This fix required sorting all of the LIB_PART draw items to ensure
accurate comparison between the symbols stored in the schematic and the
original library symbols. This has a noticeable impact on symbol library
load performance. It may also cause significant changes the next time
the library is saved due to changes in the draw item sorting. Hashing
may be a better solution here but this addressed the immediate problem.
A skeleton method SCH_SCREEN::SwapSymbolLinks() was added because there
is most likely an issue with orphaned symbols in the schematic library
symbol cache during undo/redo operations. More testing is required to
verify this.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7263
2021-03-04 17:59:24 -05:00
WhiteChairFromIkea
ff23f4324a
Do not hardcode altium file extension length
2021-03-04 12:20:40 +00:00
Ian McInerney
908de37e7c
Don't hardcode the file extensions where possible
2021-03-03 01:13:59 +00:00
WhiteChairFromIkea
2c289b3f35
Check for ".SchDoc" before replacing to ".kicad_sch" for subsheet
2021-03-02 22:30:08 +00:00
WhiteChairFromIkea
f83b9236ac
Formatting
2021-03-02 22:30:08 +00:00
WhiteChairFromIkea
b98602583c
Remove "SchDoc" and use "kicad_sch" instead for subsheet names
2021-03-02 22:30:08 +00:00
WhiteChairFromIkea
042ea9761c
Revert "Import footprint to symbols. Subsheet is name is prepended to footprint name,..."
...
This reverts commit 8aa4faa4ce24adc6310223952e8b5773ce245778
2021-03-02 22:30:08 +00:00
WhiteChairFromIkea
292aff48fd
Import footprint to symbols. Subsheet is name is prepended to footprint name, which is probably NOT OK when syncing with PCB.
2021-03-02 22:30:08 +00:00
Jeff Young
8a33542bcd
SCH_COMPONENT::GetField() expects a vector index, not a field id.
...
Check this at compile time. Callers wanting to use an index now must
use SCH_COMPONENT::GetFields()[i] instead.
Fixes https://gitlab.com/kicad/code/kicad/issues/7757
2021-02-28 15:10:37 +00:00
Roberto Fernandez Bautista
76ef98339d
CADSTAR PCB Archive Importer: Re-write loading of power symbols
...
Ensure all each power symbol is unique for each net name even
if it uses the same graphical symbol.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7722
2021-02-26 19:32:44 +00:00
Wayne Stambaugh
1786ae8773
Eeschema: use symbol nomenclature for object file naming.
2021-02-24 08:48:02 -05:00
Jeff Young
a3b9e8ddb4
Round 2 of Worksheet -> Drawing Sheet.
2021-02-23 11:57:44 +00:00
Roberto Fernandez Bautista
ccbc0f73cc
CADSTAR Schematic Archive Importer: Fix Coordinate Rounding error
...
Rewrite of the calculation to convert CADSTAR to KiCad coordinates,
rounding half way cases away from zero.
Use integer division instead of double, to ensure precision.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
842a930ced
CADSTAR Schematic Archive Importer: Autoplace fields when adding sheet
...
Makes the sheets look a little bit better when there is no block name
in the original CADSTAR design.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
7b5cf955af
CADSTAR Schematic Archive Importer: Visible fields to calculate BBOX
...
- Ensures page size is calculated correctly
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
5acdf1ddb1
CADSTAR Schematic Archive Importer: Align to original grid
...
Previous assumption of 100mil grid in CADSTAR schematic designs has
been proven to be incorrect. Let's use the "working grid" in the
original design instead.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
c98106ebcf
CADSTAR Schematic Archive Importer: Parse TESTPOINT
...
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7574
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
09ebfcd650
CADSTAR Importer: Fix Code Style
...
- Rename member variable names to use the 'm_' prefix
- Rename a few object types that clashed with KiCad object names, such
as BOARD and SCHEMATIC, to avoid the use of '::' to access the KiCad
objects.
- Remove some unused code.
2021-02-22 13:24:00 +00:00
Jeff Young
2a7e60960a
Use standard mirror icons & terminology.
...
Also use standard group icons.
Also put both (and rotate commands) in toolbar.
Fixes https://gitlab.com/kicad/code/kicad/issues/7504
2021-02-16 21:11:36 +00:00