U1 and u1 are allowed but if they both exist in the same schematic, they
will throw an ERC and annotation error. Reannotating will make them U1
and u2.
Fixes https://gitlab.com/kicad/code/kicad/issues/11862
(cherry picked from commit 00c7b64b13)
Also find a few more places where we are reaching into a new frame to
perform actions that need to have dialogs closed.
Running actions should also wait for the next cycle rather than being
immediately executed when we are calling into a new frame. This allow
for the cleanup actions onClose() to happen prior to the next action
starting
Fixes https://gitlab.com/kicad/code/kicad/issues/11891
(cherry picked from commit 93fb00d815)
Pins that are explicitly connected in the schematic should not have an
"unconnected pin" ERC error. But stacked pins do not count as
explicitly connected because the schematic designer has not connected
them
Flags are encoded using internal wx values, that can change with wxWidgets versions.
They need to be always rebuilt from the displayed options in dialog.
From master branch.
The fractional part of Altium schematic units is an integer number of
1/10000 mil segments, which is 2.54 nm. The internal unit of eeschema
is 10 nm, so each fractional unit in Altium is 0.254 base eeschema
units. To be consistent with
cf33cfcad1
we round to the nearest 10nm for each element
Fixes https://gitlab.com/kicad/code/kicad/issues/11742
(cherry picked from commit 6fef054c51)
Common settings may change colors so make sure that we refresh the draw
objects when the settings change to draw them in the proper colors.
Failing to do this may also cause left over lines on the screen
depending on OpenGL drivers
Fixes https://gitlab.com/kicad/code/kicad/issues/11921
When a rescue library already existed, the disabled writing of legacy
symbol library table entries prevented the rescue library from being
updated.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11897
(cherry picked from commit 4e7b5b9784)
The original decision to escape the legacy symbol library names results
in them being escaped every time they are opened which cause the curly
braces '}' from the original escaping to be escaped on subsequent
openings. This resulted in the symbol library names in the rescue
library not matching the library ID in the schematic.
This fix is likely to have other corner case bugs given the potential
for escaped characters in legacy symbol libraries. Given that we now
have escaped rescue libraries in play, removing the escaping will only
result in more issues so we will have to fix the corner cases as we go.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11563
"Highlight on PCB" and "Select" - "Items in Same Hierarchical Sheet"
actions were extended to select items on subsheets too.
"Highlight on PCB" now uses a proper full sheet path, allowing it to
work in subsheets.
Fixes https://gitlab.com/kicad/code/kicad/issues/11493
It looks like this was overlooked by Jeff in 2020 not realizing eda_doc isn't built under eeschema but common in cc9ac37a0e
(cherry picked from commit f85251ef75)
The legacy symbol library plugin code was changed to escape symbol names
which broke the LIB_ID string comparison when checking to see if symbols
needed to be rescued. Escaping the LIB_ID names before comparison resolves
the issue.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11563
(cherry picked from commit a19490b097)