* Do not handle tab key event when committing property changes so the
property grid tab navigation works correctly.
* Do not call commit property changes on tab key when no changes are
pending.
* Skip event handling in the base object value change and changing event
handlers in case they do not get overloaded in derived objects.
* Do not force focus to canvas on property change so arrow and tab key
grid navigation work properly. Forcing the user to click the property
grid control to edit a single property doesn't make sense.
* Pass properties panel show event up the event stack.
* Do not set focus to canvas in tool dispatcher if it already has the
focus.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/16957
manully cherry picked from commit 8a1347d2c8
Use the root schematic UUID to order projects and sort symbol instance
data by KIID_PATH. This will ensure file changes to instance data are
more consistent by using a fixed ordering.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17737
(cherry picked from commit a86a258f66)
When adding a sheet using a schematic from another project, set the
project name for the new symbol instance data to the current project
rather than the project name from the copied instance data.
(cherry picked from commit 5d99aaf0a4)
When we replace a symbol with one that has fewer pins, the old pins
are released, which leaves points to them in the connection graph
dangling. This updates the pointer to use the cloned copy in the undo
stack until the connection graph is rebuilt with the new data
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17851
(cherry picked from commit 315ad0e071)
When changing from a larger part to a smaller part, the previously
existing pins may be removed from the screen but still linked to
elements in the connection graph because we don't set them dirty unless
the changed element overlaps
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17851
(cherry picked from commit 0cd3e17db7)
Remove duplicate sheet instance page numbering. It's already done when
the sheet is loaded from an exiting file or an already loaded schematic.
Remove the unnecessary page update code from the drawing tool.
(cherry picked from commit 17bcc27ff6)
Netclass assignments are stored in the project level but
CONNECTION_GRAPH updates would clear the assignments. This keeps
existing netname->netclass assignments but updates any netnames that
were changed by the incremental updates. Absolute updates are not
affected and fully recreate the net name to netclass map
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17720
(cherry picked from commit e538b98286)
The connectivity routine would consider symbols, overwriting unused
subgraphs for pins that were not in the change list. This is resolved
by updating the full connectivity to only use pins in the graph since
symbols are not connected independently.
In the process of adding QA tests for this change, additional issues
with the schematic QA were discovered. Specifically, we were not
properly setting the root sheet UUID. This was partially masked by a
const_cast setting of the RefDes in sch_symbol when called the RefDes
getter. This exposed the fact that our QA ERC numbers did not match the
schematic editor stand alone ERC numbers. So the test value for one
check needed to be updated
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17528
(cherry picked from commit a9f35ba42e)
We don't neccesarily have a valid pointer to the parent lib symbol when
checking if it is a power symbol, so fall back to the local flag if this
is the case
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17182
Prevent the hierarchy navigator from being rebuilt unless there are actual
sheet changes that would cause a change to the tree.
Save the tree expansion state before rebuilding the tree and then restore
the expansion state to the previous state sans edits.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/16635
(cherry picked from commit 797ab998cc)
Between schematic and pcb editors, we want the following actions:
- Single click on ERC/DRC item should show the item in the ERC/DRC
window. But if the window is not visible, it should only update the
status bar
- Double click on ERC/DRC item should show and raid the ERC/DRC window
as well as select the line item
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17383
(cherry picked from commit 0f57d76ecd)
Prior to this change, the schematic connectivity was updated any time a
change was made to a connectable object. Now the connectivity is only
updated when an object change actually affects the connectivity. Other
properties like line width, fill type, custom fonts, etc. will not cause
the connectivity graph to be rebuilt.
The SCH_COMMIT flag SKIP_CONNECTIVITY has been removed. All schematic
objects can test if they are connectable and if there have been changes
to any connection properties that require a connectivity rebuild.
Remove duplicate rebuild connectivity calls from editor control tool.
This was causing the tangling end test to get called four times on every
undo and redo action because the dangling end test is already called in
the connectivity graph calculation code.
Update connectivity when changing label names which fixes an unreported
connectivity bug.
(cherry picked from commit c5a02fc266)