Commit Graph

35 Commits

Author SHA1 Message Date
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Wayne Stambaugh a06fa22b8a Eeschema: remove rogue calls to SCH_SCREEN::UpdateSymbolLinks().
SCH_SCREEN::UpdateSymbolLinks() should only be called when working with
the legacy schematic file format.  Add schematic symbol library symbol
links should be set using SCH_COMPONENT::SetLibSymbol() which updates
the symbol link and pin map accordingly.

Change the schematic symbol LIB_ID edit dialog to properly use the new
SCH_COMPONENT::SetLibSymbol() function.
2020-05-05 12:52:17 -04:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Seth Hillbrand 6e5e453d0d Replace EESchema DLIST
This moves EESchema DLIST structures to rtree.  These changes are more
fundamental than the pcbnew changes from 9163ac543 888c01d11 d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
2020-01-10 06:37:08 -08:00
Seth Hillbrand 85eed87b28 eeschema: Modify all units at the same time
When editing symbol library reference, this ensures that all units are
modified by the same action and the component is not represented by its
subunits.

Fixes: lp:1834509
* https://bugs.launchpad.net/kicad/+bug/1834509

(cherry picked from commit 80e0d848f2)
2019-08-26 20:43:05 -07:00
Jeff Young a6b36adb32 Keep value in sync with libId when they match.
Fixes: lp:1797482
* https://bugs.launchpad.net/kicad/+bug/1797482
2019-08-15 17:01:33 +01:00
Jeff Young 69f003ba4a Remove previous cell selection fixes in favour of slow-click hack.
wxWidgets has several bugs that result in cell editors being closed
right after they're opened.  There are two wxWidgets hacks to
partially address this: the SetInSetFocus() hack, and a slow-click
hack.  We used to try and work-around these bugs ourselves for
single-click access, but this changelist moves those over to
wxWidget's slow-click hack.

Fixes: lp:1817965
* https://bugs.launchpad.net/kicad/+bug/1817965
2019-03-04 11:09:33 +00:00
Jeff Young ba7b970817 Add pre-select architecture to grid helper icon-text-buttons.
Fixes: lp:1813973
* https://bugs.launchpad.net/kicad/+bug/1813973
2019-01-31 01:09:03 +00:00
Jeff Young 2c53ab3d8c Fix debug assert. 2018-12-11 17:56:41 +00:00
Tomasz Wlostowski 90c7c60471 eeschema-gal: initial GALified version. Lots of stuff still to do! 2018-10-09 11:08:52 +01:00
Jeff Young 3c2aafd7b7 Move Edit Symbol References to standard text/button control. 2018-09-29 22:07:31 +01:00
Jeff Young afacb6e7cb Improve safety around un-committed grid changes. 2018-08-21 10:34:41 +01:00
Jeff Young cb61525394 Handle separate parsing rules for ID_SCH and ID_PCB.
This removes the existing constructors so that all parsing must
be explicit and callers are made aware that they need to think
about illegal characters, malformed ids, etc.

Fixes: lp:1783474
* https://bugs.launchpad.net/kicad/+bug/1783474
2018-07-26 15:43:53 +01:00
Jeff Young 420c2020fb Overhaul Symbol Library References dialog.
Fixes some layout issues and standardizes the action buttons.
Also works around a wxWidgets bug in row sizing.

(cherry picked from commit 7abc922)
2018-07-17 15:12:58 +01:00
Jeff Young 7841f8a466 Unified preferences dialog framework.
(cherry picked from commit 8ee3e77)
2018-07-17 15:11:17 +01:00
jean-pierre charras b636aaddf6 Eeschema: fix incorrect UI messages in dialogs due to using UTF8 strings instead of wxStrings (unicode) to build them.
(Added a explicit to build a Unicode string in UI messages to avoid mistakes)
2018-04-30 11:46:23 +02:00
jean-pierre charras 4202bb6af6 DIALOG_EDIT_COMPONENTS_LIBID: fix the minimal size (previous code to fix this size was not working) 2018-04-21 17:53:54 +02:00
Simon Richter 7e47ef7471 Fix warnings for unreferenced local variables 2018-04-18 15:08:37 -04:00
Carsten Schoenert a11714b1a4 fix misspelled 'an other' -> 'another' 2018-04-08 13:24:37 -04:00
jean-pierre charras 8022f1cc01 fix code after renamin files 2018-01-30 11:49:51 +01:00
jean-pierre charras 47dfabc6c8 Add size control to HTML_MESSAGE_BOX. Fix incorrect default size of a few dialogs.
Clean code: remove useless code and not used parameters.
2018-01-11 10:48:52 +01:00
Chris Pavlina e971b0e698 Don't call FinishDialogSettings in DIALOG_EDIT_COMPONENTS_LIBID
Dialogs displaying a lot of scrollable data should use SetSizeInDU()
instead, as FinishDialogSettings() will set a minimum size equal to
whatever can contain all the data (making it overflow the screen for
large amounts).
2018-01-06 20:08:57 -07:00
Chris Pavlina 0945c319f0 eeschema: make footprint preview optional
The footprint preview and selection has been problematic for some users;
I'd rather option it out for 5.0 and work on polishing it for 6.0.
2018-01-03 18:28:44 -07:00
jean-pierre charras 7d6230ab38 Eeschema: Cannot close opening Library Browser frame when reassigning symbols from the Library Browser (wxGTK specific)
Fixes: lp:1740607
https://bugs.launchpad.net/kicad/+bug/1740607
2018-01-01 13:40:23 +01:00
jean-pierre charras 6bb349e933 Better management of KIWAY_PLAYER frame when called in modal mode, and having the wxFLOAT_ON_PARENT style option.
(previously, did not use the actual parent)
2018-01-01 10:41:43 +01:00
Wayne Stambaugh f7ab50f791 UI string normalization.
Replace all instances of "component" and "part" with "symbol" when
referring to schematic and library symbols.

Replace all instances of "component" with "footprint" when referring to
board and library footprints.

Minor dialog layout fixes to some of the dialogs impacted by the UI
string changes.
2017-12-24 10:04:32 -05:00
jean-pierre charras 2398d5ef8b DIALOG_EDIT_COMPONENTS_LIBID: enhancement in orphan automatic remap:
add dialog to choose the right candidate when more than one is found
2017-12-16 14:50:37 +01:00
Simon Richter a9ccf1161b Fix quotes in UI messages
This replaces all single and angle bracket quotes in UI messages with
double quotes, for consistency.

Sorry to all translators.
2017-12-15 07:33:07 -05:00
jean-pierre charras c0a539959e Fix a few Coverity warnings 2017-12-04 12:46:11 +01:00
jean-pierre charras cd9d81d720 dialog_edit_components_libid: add a tool to remap orphan components.
Orphan components are components that have a link (lib_id) pointing to a non existent symbol in any loaded libraries.
2017-11-23 19:49:53 +01:00
jean-pierre charras fea9d121b7 dialog_edit_components_libid: UI enhancements, and use viewlib for LIB_ID selection 2017-11-23 10:40:14 +01:00
jean-pierre charras 76d08c8bd2 UI fixes and enhancements in dialog_edit_components_libid. 2017-11-22 17:54:17 +01:00
jean-pierre charras 4d0d56fbd7 Fix incorrect handling of the last component in the component list. 2017-11-22 17:54:16 +01:00
jean-pierre charras 656d4d0dff dialog_edit_components_libid: shows orphan components (components with no symbol found in library) 2017-11-21 18:06:37 +01:00
jean-pierre charras 8507ea45fc Add a dialog to edit/change components LIB_ID inside a schematic.
This is useful for instance after moving a symbol from a lib to an other lib.
2017-11-21 11:52:40 +01:00