Commit Graph

44 Commits

Author SHA1 Message Date
Wayne Stambaugh 2078e629c5 Eeschema: allow editing of junction properties diameter and color.
Add missing plot and print changes for the new bus entry properties.

ADDED: Junction properties diameter and color can now be edited.

Fixes: https://gitlab.com/kicad/code/kicad/issues/4593
2020-06-24 13:36:17 -04:00
Wayne Stambaugh 853cf2c9b9 Eeschema: make bus wire entry properties editable.
CHANGED: Bus to wire entry object properties line color, width, and style
can now be edited.

Fixes: https://gitlab.com/kicad/code/kicad/issues/4591
2020-06-24 13:36:17 -04:00
Wayne Stambaugh 037898f6fb Eeschema: add support for excluding symbols from board.
ADDED: Support for excluding symbols from board during.  This allows for
creating bill of materials only symbols.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/2522
2020-06-10 10:57:28 -04:00
Wayne Stambaugh 77a59fb5d3 Eeschema: add support for excluding symbols from bill of materials.
This provides a method to add symbols that represent footprints on the
board that do not have an associate component such as mounting holes,
fiducials, logos, etc that should be excluded from the bill of materials.
It also prevents those footprints from being removed from the board
accidentally when updating the board from the schematic.

ADDED: Support to exclude schematic symbols from bill of materials
export.
2020-06-03 08:55:13 -04:00
Wayne Stambaugh 52078a4b1b Allow setting mandatory derived symbol field properties.
CHANGED: All mandatory fields in derived symbols can be edited.  This
not only includes the field value but also all text properties.

Kill the dual datasheet variable storage which caused many datasheet
bugs over the years.  The datasheet is now always stored in the data
sheet field.
2020-06-02 14:21:11 +00:00
Wayne Stambaugh c2d94358fc Symbol editor: minor fixes to disable saving the legacy file format.
Fixes https://gitlab.com/kicad/code/kicad/issues/4093
2020-05-29 12:43:00 +00:00
Wayne Stambaugh 06fde791f0 New schematic and symbol library file format layout changes.
Force default settings to be written instead of undefined which mimics
the behavior of the previous file format with the exception of text
objects which requires some more thought.  Please note that no new
features are added to the library file format so the file version did
not need to be updated.

Fixes https://gitlab.com/kicad/code/kicad/issues/4411
2020-05-26 12:58:57 +00:00
Jon Evans 2499a1d640 Remove KIWAY dependence from SCH_PLUGINs 2020-05-20 23:00:23 -04:00
Jon Evans 7c7b7f41da Move SCH_SCREEN project access to SCHEMATIC
SCH_SCREEN no longer needs to be a KIWAY_HOLDER
2020-05-20 22:27:48 -04:00
Wayne Stambaugh 480588866c Eeschema: toggle locale when pasting to prevent parsing errors. 2020-05-20 08:08:38 -04:00
Jon Evans f4d7c323f5 Coverity fixes 2020-05-18 22:58:28 -04:00
Wayne Stambaugh ad6857f131 Eeschema: fix copy and paste issue when non-C locales are involved.
Fixes https://gitlab.com/kicad/code/kicad/issues/4449
2020-05-18 15:47:36 -04:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Wayne Stambaugh 980aefea4b Eeschema: fix copy and paste bug.
Add required library symbols to new file formatter and parser when copying
schematic symbols to prevent missing library symbol when pasting into a
different schematic which may not have the same library symbol available.

Fix a minor bug where the default schematic symbol reference was not set
by the parser when loading.

Fixes https://gitlab.com/kicad/code/kicad/issues/4442
2020-05-15 15:53:59 -04:00
Wayne Stambaugh ad88874adf Use new file formats for copy and paste in schematic and symbol editors. 2020-05-13 18:56:19 -04:00
Jeff Young 06dea92bcb Fix issues with Kicad Manager frame and new kicad_sch files.
Fixes https://gitlab.com/kicad/code/kicad/issues/4410
2020-05-12 15:20:17 +01:00
jean-pierre charras ee08baca03 Eeschema: fix issue when saving a S expr symbol library in countries using comma as fp separator
Fixes #4381
https://gitlab.com/kicad/code/kicad/issues/4381
2020-05-09 19:39:08 +02:00
Jeff Young d0217e38cd Some clean-up from last merge. 2020-05-06 19:02:21 +01:00
Jeff Young 1f9723cf62 Reconcile new Sheet Fields and new S-expr file format.
Fixes https://gitlab.com/kicad/code/kicad/issues/4327
2020-05-06 15:48:58 +01:00
Wayne Stambaugh 91494fc561 Eeschema: add missing bus alias support to new schematic file format.
Fixes https://gitlab.com/kicad/code/kicad/issues/4335
2020-05-06 09:27:01 -04:00
Wayne Stambaugh 9c99286385 Fix a few Coverity warnings. 2020-05-05 16:42:59 -04:00
Wayne Stambaugh 0ef97ac486 Eeschema: add missing alternate body style to new schematic file format.
Fixes https://gitlab.com/kicad/code/kicad/issues/4321
2020-05-05 09:15:13 -04:00
Wayne Stambaugh a8407fba4c Fix schematic field index bug in s-expression file format plugin. 2020-05-04 12:40:03 +00:00
Wayne Stambaugh 169f63a6c0 Eeschema: make schematic sharing truly safe across all designs.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects.  It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic).  This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet.  This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references.  It also allows the root schematic from one project
to be uses as a sub-sheet in another project.

When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs.  This is done to ensure there
are no sheet path instance clashes between projects.  That being said,
there are no checks for this.  It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
jean-pierre charras 952e7a5fb4 Eeschema: move some default values to default_values.h.
These default values are used in many files, and some files were using
magic numbers.
2020-04-14 20:15:18 +02:00
jean-pierre charras 5405c09b81 Eeschema: avoid initializing default line thickness to 0: it can create issues.
Some graphic line thickness were initialized to 0.
The actual line thickness is set after reading config.
But in some cases the config does not exist, and 0 line thickness creates draw issues.
2020-04-12 19:50:33 +02:00
Jeff Young 6aaee01f1c Generalize fill parsing and add support for sheet background R/W.
Also fixes a bug in colour parsing (the alpha channel is a float).
2020-04-07 17:29:58 +01:00
Wayne Stambaugh 95089623a4 Eeschema: fix s-expression build errors due to global variable changes. 2020-04-06 22:47:42 +00:00
Wayne Stambaugh c9b00e3898 Eeschema: minor s-expression file format improvements.
I could not find a reasonable solution to the mandatory field canonical
name issue so field indices are back in play as much as I did not want
to use them.  They really only have meaning for the mandatory fields.
For all other fields, the index number is meaningless and the field name
is the primary means for searching.

Fix a broken field size bug in the symbol library formatter.
2020-04-06 22:47:42 +00:00
Wayne Stambaugh 992d141292 Eeschema: minor s-expression schematic file format improvement.
Save image data using a base64 encoded string to reduce the file size.
2020-04-06 22:47:42 +00:00
Wayne Stambaugh 2f682b6c5f Eeschema: implement s-expression schematic file format parser.
Fix a few issues with the s-expression schematic file formatter.
2020-04-06 22:47:42 +00:00
Jeff Young 591428b0d9 Remove some problematic global variables.
Fixes https://gitlab.com/kicad/code/kicad/issues/4121
2020-04-05 16:17:04 +01:00
Jeff Young 9a67dc56f9 Clean up assumption that field_id < MANDATORY means its mandatory.
It looks good, but non-mandatory fields have an ID of -1, so it
doesn't actually work.  Some places got around this by converting
the ID to unsigned, but this just hides the real issue from
unsuspecting coders.

Fixes https://gitlab.com/kicad/code/kicad/issues/4140
2020-04-01 15:59:52 +01:00
Jeff Young 4990d1e7b2 Variable substitution framework.
This implements editing of variables and moving SCH_FIELDs,
TEXTE_MODULEs, TEXTE_PCB and worksheet items over to the new
framework.
2020-03-30 14:15:59 +01:00
Jeff Young c9f8716414 Fix copy/paste error. 2020-03-16 19:17:21 +00:00
Wayne Stambaugh 7dc64f08b7 Eeschema: implement s-expression schematic file formatter.
Please note that the symbol cache is not embedded in the schematic file
to allow for round robin testing with the existing file format.  Once
the parser round robin testing is complete, the symbol cache will be
embedded in the schematic file.
2020-03-16 09:05:16 -04:00
Seth Hillbrand e359144305 Missed one file for previous commit
This is the actual fix for issue #3982
2020-03-03 14:05:49 -08:00
Wayne Stambaugh 18f9ba110d Fix minor symbol library s-expression formatter and parser bugs. 2020-03-03 08:06:23 -05:00
Wayne Stambaugh 9d6f64da9a Implement symbol library s-expression parser.
This implements all existing symbol library object support and the ability
to save and load symbol library files between file formats for round robin
testing.
2020-03-03 08:06:23 -05:00
Wayne Stambaugh 738a93db68 Fix s-expression symbol library formatter build issue due to UUID support. 2020-03-03 08:06:22 -05:00
Wayne Stambaugh 1af503509d Fix s-expression symbol library formatter build issue. 2020-03-03 08:06:22 -05:00
Wayne Stambaugh 1d205e4442 Fix points formatting in s-expression symbol library file formatter. 2020-03-03 08:06:22 -05:00
Wayne Stambaugh e1900161a7 Eeschema: implement new symbol library file s-expression formatter.
CHANGES: Symbol library file format has been converted to s-expressions.

Add support code for picking apart symbols at some future junction that
will allow full inheritance conversion of existing symbol libraries.  For
now, symbols arranged by unit and body style numbers are nested for round
robin testing of symbol libraries once the parser is complete.
2020-03-03 08:06:22 -05:00