Pcbnew: Code cleaning and bug fix in autoplace functions
Dialog exchange footprints has now a separate button to update the .cmp file, only on request.
pass into an HTML rendering panel and otherwise look goofey.
*) Implement BOARD::Move() can call it from EAGLE_PLUGIN::Load().
*) When USE_FP_LIB_TABLE, tolerate blank nicknames in FPIDs coming from eeschema.
See the switch for this in pcbnew/netlist.cpp as ALLOW_PARTIAL_FPID.
*) Add an assert and a try catch block to figure out that View does not
like some eagle pcb board. bitset::set() is getting a -1 value and firing
an exception.
Remove KICAD_GOST option because it is now useless: the 2 GOST options are now selectable at run time and are:
* specific page layouts (now user definable, and the GOST page layouts are available in template folder)
* notation for multiple parts per package (made in eeschema, preference menu)
Enhancement in Excellon file reader: accept Feed Rate and Spindle Speed definitions in Tool information line (but does not use them)
Eeschema: better name for m_SheetList (changed to m_SheetPath) member of class NETLIST_OBJECT.
* Add code to CvPcb to handle assigning component footprints from the
footprint library table instead of the search path method.
* Add code to CvPcb to allow editing of the footprint library table.
* CvPcb footprint and component panes display fully qualified FPID names.
* Make CvPcb library pane display footprint library table nicknames instead
of library file names.
* Add code to FP_LIB_TABLE object to test the paths in the table against the
list of libraries loaded from the project file.
* Add code to FP_LIB_TABLE to convert assigned footprints in a NETLIST from
legacy format to footprint library table format.
* Split out COMPONENT_NET, COMPONENT, and NETLIST objects from netlist_reader
files and create new pcb_netlist files.
* Fix minor wxListView scroll bar sizing issues.
* Add new token and code to save and load FPID nickname in board file.
* Add new token and code to save and load FPID nickname in s-expression net
list file.
* Add WX_STRING_REPORT object to dump strings to a wxString object.
* Use FPID instead of wxString in MODULE object.
* Use FPID instead of wxString when loading and saving files.
* Use FPID in COMPONENT object.
* Add wxString helper functions and comparison operators to FPID.
* Add fp_lib token to pcb and netlist file formats.
* Add code to load and save FPIDs to pcb file format.
* Fix segfault when deleting invalid footprint library tables in Pcbnew
in non footprint library table build.
* Fix bug when counting the number of mod files in
EDA_APP::SetFootprintLibTablePath();
Netlist dialog: add option to report only most important messages. Useful for large boards.
class REPORTER: add features to allow a basic message filtering (flags to report all/warning/error messages)
Fix Bug #1214599 ( tools are deselected on Move command )
* Fix both legacy and s-expression netlist readers when footprints are
assigned in the netlist.
* Add some helper functions to NETLIST for detecting when footprints are set
or not set and when they have been changed while loading the .cmp file.
* Rename a few functions to improve their readability.
* Tweak the NETLIST_READER code to allow for component footprint names that
are not found in any library to generate a warning instead of an error and
update the board accordingly.
* Don't display undo warning in netlist dialog when dry run option selected.
* Rename netlist_reader_common.cpp to netlist_reader.cpp
* Rename netlist_reader_firstformat.cpp to legacy_netlist_reader.cpp
* Rename netlist_reader_kicad.cpp to kicad_netlist_reader.cpp
* Remove cvpcb/read_write_cmpfile.cpp and move the single function it
contained into cvframe.cpp
* Remove cvpcb/loadcmp.cpp and move the single function it contained into
class_DisplayFootprintsFrame.cpp.
* Remove cvpcb/readschematicnetlist.cpp and move the single function it
contained into cvframe.cpp.
* Remove cvpcb/setvisu.cpp and move the few functions it contained into
the appropriate source file.
* Create separate NETLIST object to hold contents of netlist files.
* Read entire netlist and footprint link files before making applying
changes to board.
* Add BOARD::ReplaceNetlist() function to eliminate the calls between the
NETLIST_READER, PCB_EDIT_FRAME, and BOARD objects.
* Change placement of new components below the center of the current board
or in the center of the page if the BOARD is empty.
* Add dry run option to netlist dialog to print changes to message control
without making changes.
* Add button to netlist dialog to allow saving contents of message control
to a file.
* Eliminate the need to compile netlist_reader_*.cpp in both CvPcb and Pcbnew.
* Add netlist_reader_*.cpp to the pcbcommon library.
* Remove redundant load component link file code from CvPcb.
* Modify CvPcb new to work with the new NETLIST_READER object.
* Add compare() function and < and == operators to FPID object.
* Add REPORTER class to hide an underlying string writing implementation for
use in low level objects. Thank you Dick for the idea.
* Lots of minor coding policy, Doxygen comment, and missing license fixes.
* Complete encapsulation of the ZONE_CONTAINER class.
* Fixed a bug in the EDA_TEXT::Format() default effects behavior due to
improper conversion to internal units and missing test for default
thickness.
* Improved grammar of some Pcbnew context menu strings.
* Moved some more cleverly hidden BOARD object methods into class_board.cpp.
* Lots of coding policy and documentation fixes.
standard layer name support from BOARD::GetLayerName(). This function evolved
in a contorted direction over time, and was being asked to return one of 3
different kinds of layer names, even though it only took a boolean to control
that choice.
Users are better served by forcing them to get to know the concise new
English Standard layer names. This is because these concise names show up
in the "pretty" footprint/module files as the standard representation of
both feature and copper layers.
Change the name of BOARD::GetDefaultLayerName() to GetStandardLayerName().
Drop boolean argument to both BOARD::GetStandardLayerName() and
BOARD::GetLayerName().
* Improve MSG_PANEL_ITEM to handle message panel information.
* Create containers for passing message panel items between objects and
the message panel.
* Rename EDA_ITEM::DisplayInfo to EDA_ITEM::GetMsgPanelInfo.
* Remove all direct manipulation of EDA_DRAW_FRAME from all objects derived
from EDA_ITEM.
This required the additional compiler command line option "-std=c++0x".
2) Switch to unique_ptr from auto_ptr which is C++ deprecated.
3) Change to new English layer names per mailing list discussion, see class_board.cpp.
4) When saving to *.kicad_pcb or *.kicad_mod, identify opportunities to use wildcard
layer sets, for pads so far.
5) Switch to two std::string hashtables in pcb_parser.cpp, away from one wxString based one
for layer names and layer sets mapping. One hashtable holds the mask, the other the index.
Layer sets are only in the mask table.
6) Move "LOCALE_IO toggle" into PCB_IO::Format() since it is a public API function and
caller should find it as convenient as possible to use. LOCALE_IO should handle
nesting OK in the case where public Format() is called from one of the Footprint*()
functions.
7) Drop support for "export module to new library". Creating new libraries will have to
be handled in concert with library table entries, and we've talked recently about
creating a better footprint library manager, one that resides in a DLL/DSO. So
this kind of functionality needs to be handled in there in the near future.
8) Change name of exported PCB_IO module/footprint to *.kicad_mod and not *.emp.
can be parsed, since they do not have an overriding layer name map
like a BOARD does.
Avoid doubly looking up hashtable entries in m_layerMap.
Minor code reformatting.
and therefore tracks are now dragged when a end point is inside a pad, not necessary on the pad position.
However, drag functions still need more cleanup.
When reading board files, the net 0 was stored twice.
It creates only log messges in debug mode, because the list of nets is rebuild after reading files.
Use now English layers names to build filenames in plot functions (for techical layers), because translated names create sometimes problems in filenames.
(should do not change anything for English users)
* Use index when saving layers to handle translated layer names.
* Add LOCALE_IO switcher when loading s-expression format.
* Make SEGVIA default to through hole to improve file size.
* Don't save default orientation of 0 degrees in TEXTE_MODULE and TEXTE_PCB.
* Don't save default zone configuration parameters.
* Save multiple zone corners on a single line.
* Fixed missing ( check in graphic and module arc parsers.
* Consistency improvements for DRAWSEGMENT and EDGE_MODULE objects.
* Minor tweaks to D_PAD formatting.
* Add s-expression file parser object and keyword files.
* Fix minor issues with s-expression file formatting.
* Fix a minor bug the zone container fill state parsing in the legacy plugin.
* Move EDA_TEXT visibility definition to eda_text.h.
* Add minor BOARD_ITEM object improvements to support s-expression file
parser.
* Derive the pcbnew copper zone and non-copper zone dialog windows from DIAG_SHIM,
which injects some template code.
* Update UIpolicies.txt to talk about DIALOG_SHIM support.
* Add zone support to eagle_plugin.
* Organize ZONE_CONTAINER class declaration for future privacy and accessors.