Roberto Fernandez Bautista
9148542219
CADSTAR Schematic: Fix Text Positioning within Symbols
2021-04-12 20:25:03 +01:00
Wayne Stambaugh
2b86b34124
Eeschema: split out SCH_SHEET_PIN declarations into separate header.
2021-04-06 17:15:49 -04:00
Roberto Fernandez Bautista
d041578150
CADSTAR Schematic: Fix import of text alignment
...
Ensure that the text alignment applied to text objects corresponds to
valid text alignments that can be set within eeschema
Fixes https://gitlab.com/kicad/code/kicad/-/issues/8090
2021-04-05 20:15:08 +01:00
Carsten Schoenert
cb17c9f3dd
Typo fix: Correct various misspelled words
...
agressive -> aggressive
decription -> description
miscellanous-> miscellaneous
rectange -> rectangle
Unkown -> Unknown
2021-04-03 13:39:50 +00:00
Jeff Young
2ad69fc56b
Move importers from wxLog to REPORTER.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/6389
2021-03-31 22:54:30 +01:00
Roberto Fernandez Bautista
c5e4220b5b
CADSTAR Schematic: Fix duplicate pins
...
Fixes a bug that was causing duplicate pins to be loaded
(one on top of the other) for all symbols.
2021-03-30 13:03:56 +00:00
Roberto Fernandez Bautista
1629b038e1
CADSTAR Schematic: Fix loading of symbol instances differing from part
...
The previous assumption was that a part definition would always hold
the information about the symbol. However some designs have symbol
instances that refer to a different symbol definition than that
specified in the part.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7808
2021-03-30 13:03:56 +00:00
Roberto Fernandez Bautista
e6c7ddc271
CADSTAR Schematic: Fix loading of symbol attributes
...
Fixes an issue that resulted in incorrect field values being loaded
2021-03-30 13:03:56 +00:00
Roberto Fernandez Bautista
51db9cfcef
CADSTAR Schematic: Text Loading improvements
2021-03-30 13:03:56 +00:00
Roberto Fernandez Bautista
e0d2724f68
CADSTAR Schematic: Increase "tiny" bus labels to 0.4mm text size
...
Also fix incorrect label orientation
2021-03-25 19:10:49 +00:00
Roberto Fernandez Bautista
6494e0bf25
CADSTAR Schematic: Fix orientation of net labels and sheet pins
2021-03-25 17:50:33 +00:00
Roberto Fernandez Bautista
5a74fb9bb1
CADSTAR Schematic: Ensure connectivity with tiny labels at Bus Entries
...
Always add a label at bus terminals to ensure connectivity. The original
design might already have a bus terminal with a given location.
If the original design does not have a label, just make it very small
to keep connectivity but make the design look visually similar to
the original.
2021-03-25 17:50:33 +00:00
Jon Evans
c04e19f9ac
Include optimization: move some things from common.h to point-of-use
2021-03-20 12:09:18 -04:00
Jeff Young
8a33542bcd
SCH_COMPONENT::GetField() expects a vector index, not a field id.
...
Check this at compile time. Callers wanting to use an index now must
use SCH_COMPONENT::GetFields()[i] instead.
Fixes https://gitlab.com/kicad/code/kicad/issues/7757
2021-02-28 15:10:37 +00:00
Roberto Fernandez Bautista
76ef98339d
CADSTAR PCB Archive Importer: Re-write loading of power symbols
...
Ensure all each power symbol is unique for each net name even
if it uses the same graphical symbol.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7722
2021-02-26 19:32:44 +00:00
Roberto Fernandez Bautista
ccbc0f73cc
CADSTAR Schematic Archive Importer: Fix Coordinate Rounding error
...
Rewrite of the calculation to convert CADSTAR to KiCad coordinates,
rounding half way cases away from zero.
Use integer division instead of double, to ensure precision.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
842a930ced
CADSTAR Schematic Archive Importer: Autoplace fields when adding sheet
...
Makes the sheets look a little bit better when there is no block name
in the original CADSTAR design.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
7b5cf955af
CADSTAR Schematic Archive Importer: Visible fields to calculate BBOX
...
- Ensures page size is calculated correctly
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
5acdf1ddb1
CADSTAR Schematic Archive Importer: Align to original grid
...
Previous assumption of 100mil grid in CADSTAR schematic designs has
been proven to be incorrect. Let's use the "working grid" in the
original design instead.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
09ebfcd650
CADSTAR Importer: Fix Code Style
...
- Rename member variable names to use the 'm_' prefix
- Rename a few object types that clashed with KiCad object names, such
as BOARD and SCHEMATIC, to avoid the use of '::' to access the KiCad
objects.
- Remove some unused code.
2021-02-22 13:24:00 +00:00
Roberto Fernandez Bautista
80d8974f87
CADSTAR Archive Importer: Fix loading of non-cadstar font text sizes
...
Non-cadstar fonts use a width of 0.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
49bf957c48
CADSTAR Schematic Archive Importer: Fix positioning of global labels
...
Previous calculation did not take into account rotation of the labels
when calculating the final position.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
0841f3ae25
CADSTAR Schematic Archive Importer: Fix wires (Implied connections)
...
There is an implied connection between elements in a net even though
there might not be a graphical connection in the file.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
8add7a880d
CADSTAR Schematic Archive Importer: Fix positioning and margins
...
Fix calculation of sheet bounding box and sheet margins with the aim
of matching CADSTAR pdf output as closely as possible.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
cb90a4b7e6
CADSTAR Schematic Archive Importer: Handle Pin Swaps
...
Each schematic symbol instance can have pin numbers that diverge from
the pin number definitions in the library
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
4dc264175a
CADSTAR Schematic Archive Importer: Symbol name is case insensitive
...
Fixes an issue on some designs that would not be able to find the
symbol definition referenced by the part due to different
capitalisation of the symbol name in the part definition and
the symbol definition.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
914ae001b5
CADSTAR Schematic Archive Importer: Load pin types
...
Default to passive if undefined
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
f530b12c31
CADSTAR Schematic Archive Importer: Handle undefined pin number in part
...
Use terminal pin number (i.e. from the symbol definition) when the pin
number is undefined in the part.
This fixes a bug that resulted in symbols with "0" as the pin numbers.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
cc27c31ab0
CADSTAR Schematic Archive Importer: Import common fields visibilities
...
Import field visibilities for Ref, Value and Part Name
Also fix incorrect loading of designator from previous commit
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
297ff282f1
CADSTAR Importer: Update copyright years and remove white spaces
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
bb6fee531e
CADSTAR Schematic Archive Importer: Correctly load symbol instances
...
Previous implementation was not loading all fields defined in the
library.
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
b0051c07cb
CADSTAR Schematic Archive Importer: Load all fields in symbols
...
- Load Fields in the library items as well as schematic instances
- Remove invalid characters (e.g. '\n', '\t', '\r') in fields
- Load footprint field (assume that the footprint library name
is the same as the filename of the schematic)
2021-02-10 18:49:20 +00:00
Roberto Fernandez Bautista
b168b74919
CADSTAR Archive Importer: Fix position of multiline text with NO_ALIGNMENT in CADSTAR
2020-12-30 18:53:43 +00:00
Roberto Fernandez Bautista
a33ccf48b9
CADSTAR Schematic Archive Importer: Load signal name even if no net label (global labels and power symbols)
...
Fixes error that prevented global net names from being loaded properly
2020-12-30 18:53:43 +00:00
Roberto Fernandez Bautista
f6ec173ba7
CADSTAR Schematic Archive Importer: Do not load blocks without a linked sheet
...
Fixes std::out_of_range error
2020-12-30 18:53:43 +00:00
Roberto Fernandez Bautista
728792aa3c
CADSTAR Schematic Archive Importer: Fix SIGLOC in JPT (Load labels in junctions)
...
Fixes but that refused to open file with a SIGLOC node in JPT
2020-12-30 18:53:43 +00:00
Roberto Fernandez Bautista
a5118df44c
CADSTAR Schematic Archive Importer: Load Schematic Text Variables to KiCad project
2020-12-30 18:53:43 +00:00
Jeff Young
bb232e6ac6
Unify LIB_IDs now that both are stored in sexpr files.
...
Fixes https://gitlab.com/kicad/code/kicad/issues/6764
2020-12-18 00:30:26 +00:00
Jeff Young
10e68daa37
Fix some bugs in Change Symbol and Update Symbols.
...
In particular, there was a typo that kept library values from being
updated, and there was missing logic to fetch the various field names
from the library parts (and the change-to part).
Also implements some performance gains by desisting from copying
LIB_FIELDs around every time we want to look at them.
Fixes https://gitlab.com/kicad/code/kicad/issues/6733
Fixes https://gitlab.com/kicad/code/kicad/issues/6749
2020-12-15 16:12:17 +00:00
Ian McInerney
aa09418a14
Fixup memory lifespan of GAL options for the settings preview canvas
...
The canvas keeps a reference to the settings object, so we
can't pass one from the stack because it runs into lifetime
issues.
Also cleanup some loop-iterator problems.
Fixes https://gitlab.com/kicad/code/kicad/issues/6338
2020-12-01 01:12:07 +00:00
jean-pierre charras
56bb91b042
French translation update
2020-11-29 13:40:48 +01:00
jean-pierre charras
09a1137f11
Fix a minor compil warning
2020-11-29 13:06:44 +01:00
Roberto Fernandez Bautista
6a28d6af27
CADSTAR Schematic Archive Importer: Fix loading of Schematic Sheet Pins and Orientation of Labels
...
- Find the intersection between the wire and the sheet and place the sheet pin there
- Fix orientation of hierarchical labels and global labels by applying opposite orientation to the connecting wire
2020-11-28 17:18:17 +00:00
Roberto Fernandez Bautista
ba77bf662c
CADSTAR Schematic Importer: Fix loading of buses
...
Place bus labels and correctly group nets for the bus in a BUS_ALIAS
2020-11-28 17:18:17 +00:00
Roberto Fernandez Bautista
0691e942f4
CADSTAR Archive Importer: Fix duplicate KIID for loaded elements
...
Don't use clone to copy an EDA_ITEM. Use Duplicate().
Even if you give the clone a new KIID, all its children will still be clones.
Create Duplicate() in LIB_PART
2020-11-28 17:18:17 +00:00
Roberto Fernandez Bautista
d2fbe12cfd
CADSTAR Schematic Archive Importer: Parse SCALE token in Symbol and warn user this is not supported
...
Fixes https://gitlab.com/kicad/code/kicad/-/issues/6463
2020-11-28 17:18:17 +00:00
Roberto Fernandez Bautista
a058e26ddc
CADSTAR Schematic Archive Importer: Fix Loading of page numbers
...
Need to keep track of the hierarchy path in order to assign the page number
2020-11-28 17:18:17 +00:00
Roberto Fernandez Bautista
cba45ea257
CADSTAR Schematic Archive Importer: Fix orientation of components
...
- Fix the logic for the orientation of mirrored components
- Fix loading of angles/orientations from earlier versions of CADSTAR
2020-11-28 17:18:17 +00:00
Roberto Fernandez Bautista
49a2926a34
CADSTAR Schematic Archive Importer: Fix loading of graphical arc segments
...
Load the arc segments as piece-wise straight segments
2020-11-28 17:18:17 +00:00
Roberto Fernandez Bautista
71f9847601
CADSTAR Archive Importer: Only load the Master variant
2020-11-28 17:18:17 +00:00