1) init reference pages before trying to draw the SCH_FIELDs when
turning intersheet references on
2) don't double redraw because we accidentally cleared the last
hover item on a non-mouse-moved event.
3) make sure the root sheet gets a name for the hypertext menu.
1) Generalize SCH_ITEM owners (SCH_COMPONENT, SCH_SHEET, and now
SCH_GLOBALLABEL)
2) Generalize hypertext items
3) Use SCH_FIELD autoplace infrastructure for placing intersheet
references
4) Use textVar infrastructure for buildin intersheet references.
As an important side-effect this also fixes the undo issues with
intersheet refs.
CHANGED: GetDocumentExtents() in 'eda_draw_frame.h' now has a bool
parameter "aIncludeAllVisible" with a default value "true" which makes
it behave as it did before adding parameter. If "aIncludeAllVisible"
is false, the returned bbox ignores some items depending on which
program it is running in.
CHANGED: Made "Zoom to Objects" use only PCB edge in Pcbnew. This
allows text, notes, etc outside the PCB edge to be excluded in the
zoom calculation.
CHANGED: Added "Zoom to Objects" to Pcbnew main menu, and to RMB context
menus for Eeschema and Pcbnew.
Fixes https://gitlab.com/kicad/code/kicad/issues/5787
This may affect other EDA_DRAW_FRAME objects as well but it doesn't seem
to be as noticeable in the symbol, footprint, and worksheet editors.
Fixes https://gitlab.com/kicad/code/kicad/issues/5248
Per discussion on the developers list, this old system
no longer provides much value and is seen as annoying
by many users. The new save logic should prevent any
cases of file corruption on save, which was a major
reason for the backup file system existing.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/2012
Note: this is a basic implementation but it could be
improved once we include bus information in the netlist
and pcbnew can natively keep track of buses and nets
instead of just nets.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4158
* Move it to a panel along with the canvas to have a better UI
* Allow the infobar to automatically close after a set time
CHANGED: The eeschema find notifications now use the infobar instead of
a popup window
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of. Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
In order to avoid confusion when loading legacy schematics, updating time
stamp UUIDs is no longer performed. If users where not experiencing issues
with time stamp clashes with shared schematics then this was probably a
case of me being overly cautious.
The original conversion code has be moved to
SCH_EDIT_FRAME::ConvertTimeStampUuids() so the working functionality is
not lost. This function should not be used until a way is found to update
the board from the schematics with the appropriate settings.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects. It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic). This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet. This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references. It also allows the root schematic from one project
to be uses as a sub-sheet in another project.
When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs. This is done to ensure there
are no sheet path instance clashes between projects. That being said,
there are no checks for this. It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.
The new file formats are now the default in both the schematic and symbol
library editors. Existing symbol libraries will be saved in their current
format until new features are added to library symbols. Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted. Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.
When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier. The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.
The next save after loading a legacy schematic file will be converted to
the s-expression file format. Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.
Appending schematics requires that the schematic to append has already been
converted to the new file format. This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.
The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol. This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed. It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.
When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded. Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.
Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically. No external manipulation of this library cache should ever
occur.
ADDED: S-expression schematic and symbol library file formats.