Commit Graph

18 Commits

Author SHA1 Message Date
Maciej Suminski f31f92e45e Fixes the bug that causes pcbnew crash, when there are multiple net classes and the plot dialog was opened.
Changed NETCLASS* to boost::shared_ptr<NETCLASS>.
2014-05-20 11:29:37 +02:00
Maciej Suminski d9eb15c9fa Moved NETCLASSES to BOARD_DESIGN_SETTINGS.
Most of the changes are just adding GetDesignSettings() before every occurence of m_NetClasses.
More complex changes:
class_netclass.cpp - NETCLASS does not store the pointer to the parent BOARD anymore. Added function SetParams( BOARD_DESIGN_SETTINGS& ).
class_netclass.h - Removed GetTrackMinWidth(), GetViaMinDiameter(), GetViaMinDrill(), GetuViaMinDiameter(), GetuViaMinDrill() as they were refering to BOARD_DESIGN_SETTINGS anyway (they are not net class specific).
kicad_plugin.cpp - filters out empty nets (that are anyway not saved) when storing net class information. Previously it was done in NETCLASS::Format() function.
2014-05-13 11:22:51 +02:00
Maciej Suminski 15b8d3d20a Added NETINFO_MAPPING, to ease saving nets with consecutive net codes (without modifying the net codes during the run time).
Now, nets are saved with consecutive net codes (both modern & legacy plugins).
Zones are saved together with their nets, without depending on the fact if there are any pads with such net. Therefore validation of zone net names was removed (pcbnew/class_board.cpp).

Performed tests:
- Changed a pad's net name from empty to existent - ok, name was changed.
- Changed a pad's net name from empty to nonexistent - ok, error message is displayed, net name stays empty.
- Changed a pad's net name from existent to empty - ok, net name became empty
- Changed a pad's net name from existent to nonexistent - ok, error message is displayed, net name is not changed.

- Drawn a zone that belongs to a net, then modified schematics so the net does not exist anymore. After reloading the net list, all pads/tracks are updated. Zones still belongs to the net that does not exist in the schematic (but still exists in .kicad_pcb file). After running DRC, the zone becomes not filled.
- Undo & redo affects assignment of a polygon to a specific net (you may change net of a polygon, refill it and undo/redo the changes).

- KiCad s-expr & legacy, Eagle, P-CAD boards seem to load without any problem (they also contain correct net names assigned to the appropriate pads). All types of board file formats were loaded, then saved in sexpr format and reopened with a KiCad built from the master branch (without my modifications).
- A few boards were also saved using the legacy format and were opened with the master KiCad without any issues.

- Change a net name for a pad, restore with undo/redo - ok
- Remove everything, restore with undo - ok
- Remove everything, reload netlist - ok

Differences observed between files saved by the master branch KiCad and this one:
- list of nets are not saved in any particular order, so net codes may differ
- the default net class does not contain the unconnected net
2014-01-28 10:19:51 +01:00
Dick Hollenbeck b0c739e7ee *) Implement "Copy On Write" (COW) support in GITHUB_PLUGIN. See class header
comment for GITHUB_PLUGIN which should flow into Doxygen output.
*) Rewrote: 
        PCB_BASE_FRAME::Save_Module_In_Library(): now uses fp-lib-table and PROPERTIES.  
        PCB_EDIT_FRAME::ArchiveModulesOnBoard(): now can archive to any writable library type.
        PCB_BASE_FRAME::SelectLibrary(): is now generic for selecting a library, not just the active library.
2013-11-27 00:04:04 -06:00
Dick Hollenbeck f72394cc6b Make PLUGIN::Footprint*() API functions take 'const' PROPERTIES*.
Add const PROPERTIES* to FootprintDelete().
Add {Get,Set}Properties() to FP_LIB_TABLE::ROW.
Touch up fp table dialog.
2013-09-25 14:17:06 -05:00
Dick Hollenbeck de4cceb245 unique FPL_CACHE class names 2013-09-21 23:38:22 -05:00
Dick Hollenbeck dea9dd2361 better error reporting and parsing of bad legacy footprint libs 2013-06-13 11:09:35 -05:00
Dick Hollenbeck 2aa27122b0 Eliminate many assumptions in Pcbnew's library manager, pertaining to locality of libraries and
their type, by using the more abstract PLUGIN::Footprint*() functions.

This is an intermediate phase only, other changes will be necessary as library table support comes in.
Encapsulate usage of library path searching, since that will go away as library table support comes in.
Add FOOTPRINT_EDIT_FRAME::{get,set}LibPath() and FOOTPRINT_EDIT_FRAME::{get,set}LibNickName() functions
to provide this encapsulation.
2012-11-19 10:19:38 -06:00
Dick Hollenbeck e5452a7a39 remove "long double" dependency, mingw was falling over when using it. 2012-06-24 13:41:37 -05:00
Dick Hollenbeck 4b596cc5f3 legacy_plugin was not round tripping nanometers, add test program to verify new conversion strategy 2012-06-23 18:21:03 -05:00
Dick Hollenbeck b34d8e2150 There was no reason for insertBeforeMe on track loading.
Tracks should be loaded in the same order as they were saved, no exceptions.
This is for the version control system user.
But even with this objective now implemented in LEGACY_PLUGIN, the TRACKS
are still going through a food processor after they are loaded, and the poor
version control system user has no relief, even with this patch.

TRACKS are always modified after being loaded, and I think this needs to be fixed still.
2012-06-09 19:39:40 -05:00
Dick Hollenbeck 5cda6bc1a6 eagle plugin first work 2012-05-20 08:14:46 -05:00
Dick Hollenbeck 72d4b2353b uncrustify math_for_graphics, add copyright legacy_plugin.h 2012-04-17 09:18:14 -05:00
Dick Hollenbeck 597833b55e touch ups 2012-04-17 01:13:22 -05:00
Dick Hollenbeck 51a83a7a66 cvpcb LEGACY_PLUGIN usage factoring 2012-04-16 21:58:03 -05:00
Dick Hollenbeck 3341669fc6 more footprint support for LEGACY_PLUGIN 2012-04-16 20:35:43 -05:00
Dick Hollenbeck a42490e0f3 work on footprint plugin API 2012-04-15 22:18:41 -05:00
Wayne Stambaugh 9c16a218c0 Pcbnew s-expression file format changes.
* Save dialog now supports saving boards to new file format.
* Add CMake option to build s-expression file save.
* Add check to main CMakeList.txt file to make sure nanometers are
  enables when the new file format is built.
* Minor tweaks to object format functions for improved output.
* Rename kicad_plugin.h/cpp to legacy_plugin.h/cpp.
2012-04-07 14:05:56 -04:00