The RTree does not have a deterministic iterator, so extracting items
may be in arbitrary order, causing issues as the schematic appears to
change when comparing to previous revisions.
This uses the SCH_ITEM comparison operator to for ordering by type, then
by custom sorting within type.
For the netlist, we choose the first available unit in the sheet for
each component.
Fixes#3811 | https://gitlab.com/kicad/code/kicad/issues/3811
Scope: NETLIST_ITEM, CONNECTION_TYPE, ELECTRICAL_PINTYPE,
NET_CONNECTION, NETLIST_ITEM, GRAPHIC_PINSHAPE
Note, the pin type enum had PT_ added to the front to prevent
shadowing of the INPUT symbol on msys2 (see discussion at
c17c9960d8)
This moves EESchema DLIST structures to rtree. These changes are more
fundamental than the pcbnew changes from 9163ac543888c01d11d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
"INPUT" declaration in sch_text.h generate *a lot of* compil warnings.
So it is replaced by PS_INPUT.
For consistency, others member of enum class PINSHEETLABEL_SHAPE are also renamed.
For legacy reasons, it stored left and right "spin" as flipped integers in the file format.
But the code handled the flip in multiple locations rather than just doing it on file io.
This change unifies the internal code and does the mapping in the file I/O.
* Split up the thirdparty code into the thirdparty folder (#3637)
* Create a new kimath static library containing all the math functions
This is part of cleaning the build system for #1906.
Note that since the markup might exist for other reasons, it has
to be turned on with a preference setting. (It goes through a set
of bitflags so the same architecture can be used for other markup
structures that we might want to support in the future.)
Note also that this is more about engineering nomenclature than
visual formatting. In that respect it's more similar to overbar
than italic or bold.
The spin style is stored as a numeric and can be corrupted. We handle
this by triggering assertions for debugging the bad value while
resetting to default if we have non-valid spin values that are outside
the array.
Fixes: lp:1843091
* https://bugs.launchpad.net/kicad/+bug/1843091
This adds the functionality to add multiple labels to your schematic at
once by using spaces in the original label name.
Fixes: lp:1095113
* https://bugs.launchpad.net/kicad/+bug/1095113
Save and restore text thickness in SCH_TEXT::Plot() function to prevent
the plotting default thickness value from stepping on the original text
thickness and causing all of the text objects to magically change to bold.
Fixes lp:1823165
https://bugs.launchpad.net/kicad/+bug/1823165
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
Spacing text for plotters uses the thickness of text for two separate
classes. This sets the thickness in the EDA_TEXT class as well to allow
the multiple line positions to be correctly set
Fixes: lp:1799605
* https://bugs.launchpad.net/kicad/+bug/1799605
No dangling symbol for text items with a NO-CONNECT.
DanglingStateChanged doesn't work with dangling flag aggregators
(which return true if any child is dangling).
Then again, we don't actually use any of the aggregators anyway
so I removed them.
Fixes: lp:1799589
* https://bugs.launchpad.net/kicad/+bug/1799589
5.0 doesn't set the GAL's line width. It gets away with this since
it's using the same GAL to measure as to set up the drawing, so
the width happens to be set correctly for other reasons. 5.1 uses
a separate GAL and so isn't so lucky.
... and GetMsgPanelInfo.
Step 4 in the g_UserUnit eradication effort.
Also removes a couple of conversion routines that were close
enough to extinction.
(cherry picked from commit c75da51)
Be consistent with order, formatting, etc.
Remove debug stuff such as zone timestamp and net code.
Clean up misleading pad messages.
(cherry picked from commit 2132109)
All of the schematic object load and save code is implemented in the
legacy schematic plugin so it is no longer required.
Remove unused file with old schematic file loader.
Doxygen comment cleaning.