Commit Graph

244 Commits

Author SHA1 Message Date
Jeff Young f84406009b Push a couple of layers of indirection out of grid settings. 2020-06-13 11:35:56 +01:00
Wayne Stambaugh b624c7090a Deprecate saving legacy schematic and symbol library file formats.
REMOVED: The ability to save schematics in the legacy file format.
2020-05-29 12:43:00 +00:00
Jon Evans e934f8b459 Remove python netlist QA facilities 2020-05-23 22:48:09 -04:00
Jon Evans a63df2fbf0 Remove BuildNetListBase from netlisting paths 2020-05-23 13:14:05 -04:00
Jon Evans 2499a1d640 Remove KIWAY dependence from SCH_PLUGINs 2020-05-20 23:00:23 -04:00
Jon Evans b074cdf185 Ensure that eeschema loads project params in standalone mode 2020-05-19 23:57:53 -04:00
Ian McInerney 73a1ce3e84 Move eeschema find notification to the infobar and improve the infobar widget
* Move it to a panel along with the canvas to have a better UI
* Allow the infobar to automatically close after a set time

CHANGED: The eeschema find notifications now use the infobar instead of
a popup window
2020-05-20 02:31:47 +01:00
Wayne Stambaugh 28b8e75211 Fix duplicate time stamp bug when loading legacy schematics. 2020-05-19 11:01:00 -04:00
Ian McInerney a2f027e063 Add an infobar widget to display information above the canvas
This widget allows for non-intrusive display of text
above the editing canvas. Currently, this is used
for displaying the read only status of the files.
2020-05-19 00:46:33 +01:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Jeff Young 84160c1da4 Fix typo.
Fixes https://gitlab.com/kicad/code/kicad/issues/4448
2020-05-15 00:27:19 +01:00
jean-pierre charras 2cf82d9129 fix a wxWidgets minor alert and compil warnings 2020-05-13 08:53:32 +02:00
Jeff Young 724c669434 Move a few more commands to tool framework. 2020-05-12 18:12:38 +01:00
jean-pierre charras bc24d8e957 Fix typo and I18N string 2020-05-10 16:55:15 +02:00
Wayne Stambaugh e253862f77 Eeschema: remove automatic conversion of time stamp UUIDs.
In order to avoid confusion when loading legacy schematics, updating time
stamp UUIDs is no longer performed.  If users where not experiencing issues
with time stamp clashes with shared schematics then this was probably a
case of me being overly cautious.

The original conversion code has be moved to
SCH_EDIT_FRAME::ConvertTimeStampUuids() so the working functionality is
not lost.  This function should not be used until a way is found to update
the board from the schematics with the appropriate settings.
2020-05-07 09:26:43 -04:00
Wayne Stambaugh 9c99286385 Fix a few Coverity warnings. 2020-05-05 16:42:59 -04:00
Wayne Stambaugh 169f63a6c0 Eeschema: make schematic sharing truly safe across all designs.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects.  It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic).  This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet.  This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references.  It also allows the root schematic from one project
to be uses as a sub-sheet in another project.

When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs.  This is done to ensure there
are no sheet path instance clashes between projects.  That being said,
there are no checks for this.  It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Jon Evans 2eaefb4874 Improve performance of schematic load and connectivity
Store component paths and references efficiently
Remove redundant calls to RecalculateConnections
2020-04-30 19:53:25 +00:00
Jon Evans b802a3e776 Add command-line option to generate netlist and exit 2020-04-19 19:13:24 -04:00
Jeff Young 2b6089240a Change super/subscript syntax to ^{foo} and _{foo}. 2020-04-18 21:04:41 +01:00
Jeff Young 9c8941e040 Remove a bunch of globals. 2020-04-16 17:34:46 +01:00
Jeff Young 122b1ddaae Unwrap an unnecessary layer now that we have new config stuff. 2020-04-13 20:58:12 +01:00
Wayne Stambaugh 2f682b6c5f Eeschema: implement s-expression schematic file format parser.
Fix a few issues with the s-expression schematic file formatter.
2020-04-06 22:47:42 +00:00
Jeff Young b13559c926 Add envVar and text variable resolution to plot directory paths.
Fixes https://gitlab.com/kicad/code/kicad/issues/3808
2020-04-05 23:56:24 +01:00
jean-pierre charras b1b8a32078 fix a few Coverity warnings and compil minor warnings. 2020-04-03 09:54:47 +02:00
Wayne Stambaugh 7dc64f08b7 Eeschema: implement s-expression schematic file formatter.
Please note that the symbol cache is not embedded in the schematic file
to allow for round robin testing with the existing file format.  Once
the parser round robin testing is complete, the symbol cache will be
embedded in the schematic file.
2020-03-16 09:05:16 -04:00
Jeff Young 85c2e0d23a Add user-defined severities, exclusions and colors to DRC markers.
Exclusions are currently persisted in the project file.

Fixes https://gitlab.com/kicad/code/kicad/issues/1989
2020-03-04 00:39:28 +00:00
Jeff Young 490f39a671 Remove obsolete code requiring unique sheet names. 2020-02-20 22:56:11 +00:00
Jeff Young 81dd1d7a68 Timestamp-based paths were ugly. UUID-based ones are worse.
Show a human-readable path in the Edit Footprint dialog.
2020-02-20 21:29:52 +00:00
Jon Evans e59a3d981e Implement a new settings framework across all of KiCad
CHANGED: Settings are now stored in versioned sub-directories
ADDED: First-run dialog for migrating settings from a previous version
CHANGED: Settings are now stored as JSON files instead of wxConfig-style INI files
CHANGED: Color settings are now all stored in a separate settings file
CHANGED: The symbol editor and footprint editor now have their own settings files
CHANGED: Color settings are no longer exposed through BOARD object
CHANGED: Page layout editor now uses Eeschema's color scheme

Settings are now managed through a central SETTINGS_MANAGER held by PGM_BASE.
Existing settings will be migrated from the wxConfig format on first run of each application.
Per-application settings are now stored in one class for each application.
2020-02-19 23:44:56 -05:00
Seth Hillbrand 6e5e453d0d Replace EESchema DLIST
This moves EESchema DLIST structures to rtree.  These changes are more
fundamental than the pcbnew changes from 9163ac543 888c01d11 d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
2020-01-10 06:37:08 -08:00
Ian McInerney 079423c3cc eeschema: Remove unused include of eeschema_id.h 2020-01-03 16:04:54 +00:00
Mark Roszko 686b768a3d Add shutdown blocking on Windows for pcbnew, eeschema and pleditor
ADDED: Block shutdown/logoff on Windows when contents have been modified
2019-12-19 14:11:11 +00:00
Wayne Stambaugh 30da2b31ea Eeschema: fix multiple symbol rescue bug caused by commit 54f066fe.
Use the root symbol when comparing against the cached symbol when
checking to see if a symbol changed.  When the original symbol is
a derived symbol, the test will always fail.

Force a symbol link refresh on a rescue to prevent stale links from
crashing the connection graph refresh when running the project rescue
on demand.

Force a symbol link refresh on project load to prevent stale links from
symbol link changes from crashing the connection graph when the project
rescue in invoked.

Fixes kicad/code/kicad#3645
2019-12-09 14:47:29 -05:00
Jeff Young 9d288968e7 Be more explicit about extent of schematic cleanups.
The new connectivity algorithm had a tendency to cleanup
globally, but that could insert undo records from other sheets
into the current screen's undo stack.  Needless to say, this
was a recipie for segfaults.

Fixes: lp:1846247
* https://bugs.launchpad.net/kicad/+bug/1846247
2019-11-10 23:25:54 +00:00
Wayne Stambaugh 8789ab9265 Eeschema: remove rogue symbol libraries from project file.
Check for symbol libraries that somehow ended up in the project file
after remapping occurred and remove all of them to prevent potentially
broken symbol library links.

Add nagware dialog to warn the user and a checkbox to never show the
dialog again.

Fixes lp:1838185

https://bugs.launchpad.net/kicad/+bug/1838185
2019-08-01 13:26:21 -04:00
Wayne Stambaugh b595dc0d3b Eeschema: fix edit sheet bug.
Remove an existing sheet from the current page that requires a schematic
load from file to prevent a corrupt screen list from causing a segfault.

Merge the edit sheet file loading with the append schematic code since
they are functionally the same.  This allows the sheet edit code to
take advantage of all of the added broken symbol library links added in
the recent append schematic fixes.

Fixes lp:1835841

https://bugs.launchpad.net/kicad/+bug/1835841
2019-07-30 08:21:33 -04:00
Seth Hillbrand 7759ad7e27 eeschema: Clean up backup name
This fixes the last suffix that was missed by 168fa09f5.  The schematic
backup files should have the suffix .sch-bak to distinguish from
.kicad_pcb-bak or other backups.

(cherry picked from commit b6fe4ff637)
2019-07-23 16:15:04 -07:00
Wayne Stambaugh 9fae30162d Eeschema: fix many append schematic bugs.
Do not add cache library from another project to old library list.  This
is wrong and can cause all kinds of symbol library linking issues.  It's
better to force the user to fix broken symbol library links than the false
security of using multiple cache libraries.

Use correct paths when appending schematic outside of the current project
path when hierarchical sheets are appended.  If the path can be relative,
give the user the option to use either relative or absolute paths.

Do not change symbol library names in schematics appended from a source
outside the current project.  This will almost ensure the symbol library
links will be broken in the source project.

When the appended schematic is from another project, attempt to check all
of the possible combinations of symbol library table importing that could
cause broken symbol library links and give the user the option of canceling
the append operation or live with the possibility that there may be broken
symbol library links.

When the append schematic is in the current project path but not part of
the schematic, check to see if there are any library nicknames that do
no exist in the project symbol library table and give the user a chance
to cancel the append process.
2019-07-19 11:39:29 -04:00
Tomasz Włostowski d7fe307913 eeschema: automatically insert junctions at pin connections if needed during file load
EEschema optimizes wires by merging colinear segments. If a schematic opened without a valid
cache library or missing installed libraries and later saved, this optimization can cause connectivity
errors. In order to fix that we check each pin-wire connection and junctions if necessary.
2019-06-25 01:06:25 +02:00
Jeff Young 4eab89d9ef Fix OSX button order issue in Unsaved Changes dialog.
Also changes the presentation of the string when the checkbox appears
so that the "Changes will be lost" warning isn't hidden by the turndown.
This last part may require conditional compilation as it's undocumented.

Lastly, regularizes the Unsaved Changes strings between the apps.
2019-06-17 17:01:57 +01:00
Jeff Young 1ea001d497 Go back to event-loop zooming for new frames.
The immediate mode appears to have made things worse not better.
2019-06-04 13:56:54 +01:00
Jeff Young bdd44ce88c Use consistent PageLayout data structure names. 2019-05-27 11:55:58 +01:00
Jeff Young a3dfce5adb Implement common file menu actions and move Eeschema over. 2019-05-25 01:14:21 +01:00
Jeff Young 323bb0f8e1 Moving PageLayout editor to GAL canvas and modern toolset. 2019-05-24 19:49:09 +01:00
Seth Hillbrand b53b29399d eeschema: Ensure conn is updated after import
After importing Eagle files, we need to make sure that the connectivity
network is updated before the system requests a new netlist.  Otherwise,
we end up with different results from the first to second updates.
2019-05-21 19:31:59 -07:00
Tomasz Włostowski aff3243f3b eeschema: fix use-after-free crash in GetScreen()/GetCurrentSheet() 2019-05-20 21:04:46 +02:00
Jeff Young e850592587 Cleanup. 2019-05-15 17:50:52 +01:00
Jeff Young 7995b5cc3c Restore selection on abort and undo/redo.
Also includes a related bug fix to not create an undo record for
the initial schematic cleanup.

Fixes: lp:1825975
* https://bugs.launchpad.net/kicad/+bug/1825975
2019-05-11 15:38:49 +01:00