* Remove most (not all) variables that were initialized but never used that
cause GCC 4.6 to generate a warning.
* Fix bug in schematic library editor best zoom calculation.
Pcbnew: refresh issue with dialog designe rules under wxWidgets 2.9.2 under WINDOWS (replace wxChoiceBox by wxComboBox, should not change anything for users)
Eeschema: some issues in libedit (when editing a pin )
(WxWidgets 2.9.1 seems call setlocale( LC_NUMERIC, "" ) when wxConfig read doubles stored in config, but forget to back to current locale.)
Note: perhaps there are some dialogs that need this call to SetLocaleTo_Default() ).
* Minor code cleanup in pcbnew/netlist.cpp
* Fix grid select box update bug on context menu.
* Fix via size and track width select box update bugs.
* Fix layer pair indicator button update bug.
* Fix auto track width tool bar control enable bug.
* Fix via size and track width select status bug in context menu.
* Fix layer select box and layer control widget select bug when current
layer is removed.
* Add virtual function to notify objects derived from EDA_DRAW_FRAME that
the units setting has changed.
* Coding policy class naming fixes.
* Remove base screen methods from draw frame object and correct current
screen methods in derived objects.
* Move restore old wires function code into schematic screen object.
* Make add junction method use current screen position instead of store
position.
* Move poly line ghosting function into the delete current segment method
as that was the only place is was being used.
* Add method to base schematic object of testing if object has a label
that can be incremented.
* Simplified the schematic hierarchy traversing code.
* PCBNew Doxygen warning fixes.
* PCBNew remembers last net list read during the current editing session
as well as between project editing sessions. Closes bug 576902.
* Separate PCBNew application settings from project file settings and
allocate them dynamically instead of statically to make it easier to
eliminate global variables.
================================================================================
+eeschema
* commiting my changes to allow multiple instances of a given schematic file within
a hierarchy:
** internally, m_currentScreen has been replaced with m_currentSheet,
which is a list or 'path' of screens. The path of screens is used to
generate
a series of timestamps, which is converted to flat component reference via
a look-up
table in the schematic files.
** this means that m_currentScreen is no longer used -- use GetScreen().
** GetScreen is virtual, as some of the dialogs keep around a WinEDA_BaseScreen
pointer.
** all sub-sheets in a given schematic must have different names to generate a
meaningful netlist.