Commit Graph

429 Commits

Author SHA1 Message Date
Marek Roszko f341fde938 Move RecordERCExclusions and ResolveERCExclusions out of the schematic frame 2023-08-13 19:50:05 -04:00
Seth Hillbrand 7fe83993cf Be smarter about releasing lockfiles
If KiCad crashes or exits without deleting the lockfile, don't show the
warning message unless we are not the one who locked it or there are
other KiCad instances running locally.

This should catch 99% of the cases where the message is shown
incorrectly.  There may be some corner cases where the lock file is
created on a network drive using two different machines with the same
name and same user but these cases should be (famous last words)
sufficiently rare as to not be observed in practice
2023-07-21 15:40:19 -07:00
Alex Shvartzkop cab0db76f8 Clear view before resetting schematic.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15159
2023-07-11 03:00:42 +05:00
jean-pierre charras 3ef757e3b9 EEschema: hide the splash screen before reading a file, to avoid obfuscate
a info dialog, if any.
Fixes #15076
https://gitlab.com/kicad/code/kicad/-/issues/15076
2023-06-29 12:34:04 +02:00
Ian McInerney 2fb6f19a84 Separate immediate and delayed action dispatch
Using a boolean argument just leads to a lot of trailing booleans in the
function calls and is not user friendly. Instead, introduce PostAction()
to send an action that runs after the coroutine (equivalent to passing
false or the default argument), and leave RunAction as the immediate
execution function.
2023-06-27 00:57:59 +01:00
Jeff Young 20d2568f0c Move where we fire EDA_EVT_SCHEMATIC_CHANGED again.
The location in HARD_REDRAW got called everytime we change schematic
pages, which is not what we want.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/14945
2023-06-13 16:36:05 +01:00
Jeff Young 61493b8489 Return all results with an empty search pane filter.
Also moves the EDA_EVT_SCHEMATIC_CHANGED event so it fires after the
schematic has been loaded.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/14871
2023-06-10 23:05:57 +01:00
Jeff Young e698156975 Upgrade many editing actions to SCHEMATIC_COMMIT. 2023-06-09 22:41:47 +01:00
Seth Hillbrand 5370fdc718 Fix override lock behavior
We don't need to lock in import because we are creating a new file.  We
should, however, show the locking user/machine when opening in schematic
editor and take over the lock if they want to proceed.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/9347
2023-05-31 13:43:58 -07:00
Seth Hillbrand 48ecd742eb Maintain file permissions when renaming
Temporary and autosave files do not neccessarily have the correct
permissions set to replace existing project files.  This updates the
permissions to match the existing values where possible

Fixes https://gitlab.com/kicad/code/kicad/-/issues/13574
2023-05-24 17:09:38 -07:00
Seth Hillbrand 122be418bb Upgrade file locking
wxSingleInstanceChecker is meant for running programs, not file locking.
This implements an RAII class for file locking that stores the lock
files next to the file being locked, allowing it to be easily found and
removed.  Also includes the ability to override the lock, with
information about the original owner

Fixes https://gitlab.com/kicad/code/kicad/-/issues/14734
2023-05-24 13:51:54 -07:00
Jeff Young 69500bfcaa LTSpice schematic import based on the work of Chetan Shinde. 2023-04-24 13:52:52 +01:00
Jeff Young 66f48d56ae Separate sheet reloads (MODEL_RELOAD) and schematic reloads (SUPERMODEL_RELOAD).
Fixes https://gitlab.com/kicad/code/kicad/issues/14523
2023-04-12 11:51:09 +01:00
Marek Roszko 8a8589b9db Fix cli crash due to dialogs buried in the pcb parser...
Fixes sentry KICAD-Q2
2023-03-24 19:52:48 -04:00
Jeff Young c4ef08bead Exercise more caution with user filenames.
In particular, don't assume "1" is an extension in "Schematic_1.1".

Fixes https://gitlab.com/kicad/code/kicad/issues/14263
2023-03-12 15:52:45 +00:00
jean-pierre charras b96f3d085c Eeschema: save worksheet filename in project file.
The call to saveProjectSettings() was missing.
Fixes #14219
https://gitlab.com/kicad/code/kicad/issues/14219
2023-03-09 15:56:19 +01:00
Jeff Young b6d0b65261 Naming conventions and commenting. No functional changes. 2023-03-04 00:10:01 +00:00
Mike Williams 959a19a461 Power Symbols: automatically fix mismatched legacy symbols, add tests
Has netlist generation test for legacy power symbols, and test for
fixing legacy mismatched power symbol text fields and invisible pin names.
2023-02-22 18:01:47 +00:00
Marek Roszko 0ff32d20cd wxS more things 2023-01-22 09:41:42 -05:00
Seth Hillbrand e6dbca051c Force realtime connectivity on
The pressure relief valve was not useful for common work patterns as it
forced the recalculation on many common actions such as bus expansion.
This caused it to actually feel slower than with the pressure relief
valve off.

For most schematics, realtime is now fast enough to not need the valve
and for those that are extremely complex, removing the valve helps this
run more predictably
2023-01-20 15:17:57 -08:00
Seth Hillbrand 7e5a2450b8 Move multiple wxMessageBox to DisplayErrorMessage
Also provide protection for headless running in multiple callsites

Fixes https://gitlab.com/kicad/code/kicad/issues/13575
2023-01-18 16:54:01 -08:00
Wayne Stambaugh f81642bbb3 Fix broken graphics import file filters.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13570
2023-01-17 11:19:53 -05:00
Marek Roszko d2c0f5fc2a More wxSing 2023-01-16 23:14:38 -05:00
Roberto Fernandez Bautista ff717fec3f Wait to save non-KiCad imported drawing sheet until user requests a save 2023-01-15 19:17:50 +01:00
Roberto Fernandez Bautista d063eb431b Move FixupJunctions to SCHEMATIC 2023-01-15 19:17:50 +01:00
Seth Hillbrand f4ac4be701 Fix naming of `updateTitle()`
This is a private function so should be lowercased to avoid confusion
2023-01-11 16:06:20 -08:00
Jeff Young 4c63b4e061 Class name <-> file name sync. 2022-12-29 18:05:57 +00:00
Jon Evans 314c813aca Don't try to save hierarchical sheets with empty filenames
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11236
2022-12-26 21:47:17 -05:00
Ian McInerney 0bd39516c4 Cleanup eeschema save as extra control creation to match pcbnew 2022-12-17 23:37:24 +00:00
Jeff Young 6535f407a6 Remove version guard from sim migration, and add migration to paste.
Fixes https://gitlab.com/kicad/code/kicad/issues/13080
2022-12-08 23:57:42 +00:00
Jeff Young b9287968d6 Update symbol default prefixes after updating instance data.
Also moves the sim model fixups after the instance data updating as
it uses the prefixes.
2022-12-07 01:34:56 +00:00
Wayne Stambaugh da0624286c Fix spelling error in schematic import exception handler. 2022-12-06 18:04:38 -05:00
Jeff Young 38906397d2 Move V6->V7 sim model migration from sheets to screens.
Also moves passive RLC inference out from migration to just-in-time
creation for the simulator or netlisting.

Also fixes a version guard mismatch because the spice migration was
done inside UpdateSymbolInstances (which has its own version guard).

Also changed UpdateSymbolInstances to UpdateSymbolInstanceData so
someone else in the future doesn't think it's a general-purpose symbol
instance updater.
2022-12-06 16:01:18 +00:00
Wayne Stambaugh 5001555f0e Fix crash in Altium schematic importer.
The crash was caused by an unhandled exception. The uncaught exception
caused a cacophony of null configuration setting pointers so guards were
added to prevent crashes should other exceptions occur that do not get
handled correctly.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/13046
2022-12-05 20:20:01 -05:00
Jeff Young 96819f6c01 Better cache invalidation for text objects with references.
Fixes https://gitlab.com/kicad/code/kicad/issues/13059
2022-12-04 11:51:44 +00:00
Wayne Stambaugh 4a27d856f7 Move schematic sheet instance information into file sheet definition.
This will make it possible to maintain sheet instance information when
copying and pasting from any sheet other that the root sheet of a
project.

Setting and getting sheet page numbers must now be performed using a
sheet path.  This was done to ensure that the instance paths were not
getting changed unexpectedly from different code paths.
2022-11-22 16:45:38 -05:00
Simon Schaak bd74489b00 Clean up autosave file handling edge cases 2022-11-22 15:21:26 +00:00
Sylwester Kocjan a234d5a2c8 common,eeschema,pcbnew: path cleanup 2022-11-02 13:29:52 +00:00
Wayne Stambaugh 349de90bb0 Fix Altium schematic importer bug(s).
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11412
2022-10-31 10:03:35 -04:00
Wayne Stambaugh 85805bdad7 Fix broken legacy file format symbol instance data import. 2022-10-19 12:23:28 -04:00
Wayne Stambaugh 2a13c0af2e Revert commented out code. 2022-10-18 16:07:14 -04:00
Wayne Stambaugh f782323960 Fix yet another symbol instance issue when loading legacy schematics. 2022-10-15 14:16:03 -04:00
Jeff Young ad5df7f4cc More busy cursor tightening.
Fixes https://gitlab.com/kicad/code/kicad/issues/11648
2022-10-11 23:40:58 +01:00
Jeff Young 8206283a20 Code clarity. 2022-10-11 11:22:26 +01:00
Jeff Young 3221877fe8 Push autosave-require down in to EDA_BASE_FRAME.
Fixes https://gitlab.com/kicad/code/kicad/issues/11790
2022-10-10 14:03:52 +01:00
Jeff Young be6f08deca Code clarity. (No functional changes.) 2022-10-10 14:03:52 +01:00
Wayne Stambaugh a11c40197f Expunge default symbol instance from schematic file format.
Now that importing hierarchical sheets "properly" imports instance data,
the default symbol instance setting doesn't have any meaning.
2022-10-04 15:42:41 -04:00
Wayne Stambaugh 2b387ae9c3 Move schematic symbol instance data back into symbol definition.
This change reverts the storage of all symbol instance data in the root
schematic.  This was done because it's not possible to reuse instance
data when importing from sub-sheets.

There has been a fundamental change in how sheet paths are store in the
instance data.  The root schematic UUID is always used when saving the
instance data.  To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project.  This provides a way
to determine the project that stored the instance data.  All uses of paths
without root sheet have been expunged from the code.

The sheet instance data is still saved only in the root sheet for the
time being.  New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number.  Sheet page
numbers will not be imported.

Added project name to instance data to improve the readability of the
schematic file format.  It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
2022-10-02 15:06:42 -04:00
Wayne Stambaugh 979b4a4eb7 Revert "Move schematic symbol instance data back into symbol definition."
This reverts commit 7984e114db.
2022-09-29 15:33:23 -04:00
Wayne Stambaugh 7984e114db Move schematic symbol instance data back into symbol definition.
This change reverts the storage of all symbol instance data in the root
schematic.  This was done because it's not possible to reuse instance
data when importing from sub-sheets.

There has been a fundamental change in how sheet paths are store in the
instance data.  The root schematic UUID is always used when saving the
instance data.  To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project.  This provides a way
to determine the project that stored the instance data.  All uses of paths
without root sheet have been expunged from the code.

The sheet instance data is still saved only in the root sheet for the
time being.  New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number.  Sheet page
numbers will not be imported.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
2022-09-29 17:47:57 +00:00