If KiCad crashes or exits without deleting the lockfile, don't show the
warning message unless we are not the one who locked it or there are
other KiCad instances running locally.
This should catch 99% of the cases where the message is shown
incorrectly. There may be some corner cases where the lock file is
created on a network drive using two different machines with the same
name and same user but these cases should be (famous last words)
sufficiently rare as to not be observed in practice
Using a boolean argument just leads to a lot of trailing booleans in the
function calls and is not user friendly. Instead, introduce PostAction()
to send an action that runs after the coroutine (equivalent to passing
false or the default argument), and leave RunAction as the immediate
execution function.
We don't need to lock in import because we are creating a new file. We
should, however, show the locking user/machine when opening in schematic
editor and take over the lock if they want to proceed.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/9347
Temporary and autosave files do not neccessarily have the correct
permissions set to replace existing project files. This updates the
permissions to match the existing values where possible
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13574
wxSingleInstanceChecker is meant for running programs, not file locking.
This implements an RAII class for file locking that stores the lock
files next to the file being locked, allowing it to be easily found and
removed. Also includes the ability to override the lock, with
information about the original owner
Fixes https://gitlab.com/kicad/code/kicad/-/issues/14734
The pressure relief valve was not useful for common work patterns as it
forced the recalculation on many common actions such as bus expansion.
This caused it to actually feel slower than with the pressure relief
valve off.
For most schematics, realtime is now fast enough to not need the valve
and for those that are extremely complex, removing the valve helps this
run more predictably
Also moves passive RLC inference out from migration to just-in-time
creation for the simulator or netlisting.
Also fixes a version guard mismatch because the spice migration was
done inside UpdateSymbolInstances (which has its own version guard).
Also changed UpdateSymbolInstances to UpdateSymbolInstanceData so
someone else in the future doesn't think it's a general-purpose symbol
instance updater.
The crash was caused by an unhandled exception. The uncaught exception
caused a cacophony of null configuration setting pointers so guards were
added to prevent crashes should other exceptions occur that do not get
handled correctly.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13046
This will make it possible to maintain sheet instance information when
copying and pasting from any sheet other that the root sheet of a
project.
Setting and getting sheet page numbers must now be performed using a
sheet path. This was done to ensure that the instance paths were not
getting changed unexpectedly from different code paths.
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Added project name to instance data to improve the readability of the
schematic file format. It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472