This allows a setting where the path is not one of the options. This
permits the user to select once to go to any path option (rather than
off the current and then back to currect) when the filetree doesn't
match the dropdown. This also selects the drop down item if it matches
the tree.
Drop all uses of wxRAISED_BORDER and wxSUNKEN_BORDER from dialogs and
panels used in main frame windows.
Drop use of wxSP_3DSASH options on all wxSplitterWindow definitions.
Minor dialog alignment and spacing fixes.
Passing an empty path to the 3D model select dialog results in the file
select control displaying the root path which requires the user to drill
down to get to the 3D models. Use the KISYS3DMOD path as the default
and fall back to the project path as required for the initial file
select control path.
Clean up some coding policy violations.
Fixes lp:1737094
https://bugs.launchpad.net/kicad/+bug/1737094
* Split and rewrite the preview window and canvas.
* Create a new class for handling the board information.
* Adds new render targets: openGL, legacy, and ray tracing.
* Render targets take full advantage of the new 3D plugins system and 3D cache
for a fast 3D model loading.
* Faster board loading.
* New OpenGL render is faster than the old one.
* New ray tracing render target with a post processing shader.
* Use of new 3D plugins (WRL, X3D, STEP and IGES) and 3D model caching.
* Preview of 3D model while browsing the file name.
* 3D preview of the footprint while adding / align 3D shapes.
* Render of 3D models according to attributes: Normal, Normal+Insert, Virtual.
* Pivot rotation centered in one point over the PCB board.
* Shortcuts keys improved for XYZ orientation..
* Animated camera.
* Paths defined via pcbnew->Preferences->Configure Paths are now included in
the 3D file browser's drop-down list except for KICAD_PTEMPLATES, KIGITHUB,
KISYSMOD, any paths resembling a URL, and any non-existent paths. When an
absolute path is shortened using one of these path aliases, let's say
'KISYS3DMOD' then the name appears in the pcb file as "${KISYS3DMOD}/blah.wrl".
If a user defines and actual environment variable with the same name, then
that user defined variable will have precedence over the internally defined
variable.
* Paths relative to the current project directory are no longer represented
as "some/path/to/file.wrl". For compatibility with previous KiCad versions
it shall always be stored as ${KIPRJMOD}/some/path/to/file.wrl.
* Various restrictions on alias path values have been removed since the
imposed restrictions could result in corrupted user data as aliases are
silently dropped.
* Overall the patch should improve back-compatibility by providing a ${ENV_VAR}
mechanism for supporting different model root directories and ensuring that
paths relative to KIPRJMOD are expressed in a way that is compatible with
earlier KiCad versions. This allows users more flexibility and the ability
to work in a way that ensures 3D model files can be correctly resolved in
earlier versions of KiCad. Users who do not care about back-compatibility
may prefer to use the newer alias system.