Commit Graph

14 Commits

Author SHA1 Message Date
Jeff Young 39d4e422ea Better approximation for pads in Export Gerber to Pcbnew
We can't get all the way there because we can't create pads outside
of modules and the Gerbers don't store any grouping/footprint info.
This change moves us from outputing a via for every flashed item
(some of which don't even have holes) to synthesizing pads from
flashed items using a via (when they have holes) and a copper polygon.

This is much better for SMD pads, perhaps better for regular pads,
and no worse for vias.
2020-06-06 16:38:14 +01:00
jean-pierre charras 9dedbc74a3 Gerbview exporter: fix a wxASSERT. 2018-12-21 13:48:00 +01:00
Jon Evans 3ec28e2acf Refactor layer enumerations to all live in the same place 2017-03-30 16:01:48 -04:00
Wayne Stambaugh 40779a08ce More missing source license fixes. 2014-10-21 14:36:45 -04:00
jean-pierre charras a82127277c Gerbview: fix scaling error in x.6 file format. Minor cleaning code.
Better separation between Pcbnew code and Gerber code.
Update export to Pcb code (uses now the version 4  kicad_pcb file format).
2014-07-14 20:59:41 +02:00
jean-pierre charras 013296cb1a Make gerbview compilable and working (does not use now layers and layer masks from Pcbnew).
Export to Pcbnew is broken, but it is a very rarely used feature. It will be fixed later.
2014-06-27 19:07:42 +02:00
Dick Hollenbeck 4578ea8b9e 1) Add 32 Cu Layers.
2) Change from legacy Cu stack to counting down from top=(F_Cu or 0).
   The old Cu stack required knowing the count of Cu layers to make
   sense of the layer number when converting to many exported file types.
   The new Cu stack is more commonly used, although ours still gives
   B_Cu a fixed number.
3) Introduce class LSET and enum LAYER_ID.
4) Change *.kicad_pcb file format version to 4 from 3.
5) Change fixed names Inner1_Cu-Inner14_Cu to In1_Cu-In30_Cu and their
   meanings are typically flipped.
6) Moved the #define LAYER_N_* stuff into legacy_plugin.cpp where they
   can die a quiet death, and switch to enum LAYER_ID symbols throughout.
7) Removed the LEGACY_PLUGIN::Save() and FootprintSave() functions.
   You will need to convert to the format immediately, *.kicad_pcb and
   *.kicad_mod (=pretty) since legacy format was never going to know
   about 32 Cu layers and additional technical layers and the reversed Cu
   stack.
2014-06-24 11:17:18 -05:00
jean-pierre charras 9f9f2ed380 Minor code cleaning: Remove unused file, remove obsolete or useless defines 2013-11-15 10:28:31 +01:00
Lorenzo Marcantonio 4cbbce3aa6 Removed ugly usage of an extra layer slot for the layer count in gerbview
Fixed layer picker for exporting to pcbnew
Realigned pcb layer name with class BOARD
2013-04-10 09:03:19 +02:00
Lorenzo Marcantonio 9fd79dfa91 Implemented the LAYER_NUM typedef (LAYER was already taken as a class name...) to represent a layer number. 2013-03-31 15:27:46 +02:00
Wayne Stambaugh 63b884558a Doxygen warning fixes. 2012-12-18 08:54:44 -05:00
Dick Hollenbeck 28222961dd fix ownership issue in wxFFile vs. FILE_LINE_READER 2012-10-24 13:42:39 -05:00
jean-pierre charras d9ed8a3085 Pcbnew: automatic selection of plugin when loading a file with .kicad_pcb extension from history list.
Very minor other fixes
2012-06-14 21:10:32 +02:00
jean-pierre charras 4125ea7789 Gerbview: remove dependencies from Pcbnew.
Should allow Pcbnew code easier to change and Gerbview code more understandable and easier to maintain.
Code cleaning (remove dead code, add comments).
Minor other enhancements.
2012-05-04 19:44:42 +02:00