The reason the component tree widget was cleared on Windows is the fact
m_adapter->UpdateSearchString( m_query_ctrl->GetLineText( 0 ) ) is
called on any change of the symbol. But if m_query_ctrl is empty,
m_query_ctrl->GetLineText( 0 ) returns the "hint" (currently the word
"Search") not the actual value, so there is no "candidate" symbol in
list. Using m_query_ctrl->GetValue() returns the actual value and fixes
this issue.
Fixes: lp:1737132
* https://bugs.launchpad.net/kicad/+bug/1737132
Pins are weak_ptrs to the library, so they require a lock() before
accessing. This imposes a performance hit on fast loops that access
the pin list repeatedly. This patch caches the pin position locally
for each component, updating only when needed.
Fixes: lp:1737363
* https://bugs.launchpad.net/kicad/+bug/1737363
COMPONENT_TREE::STATE used wxDataViewItem to store the selection, but it
will point to a deleted object if the selection was removed. Switched to
storing the selection using LIB_ID as it is much safer to use.
Show the NC box only on pins connected via the same component,
indicating a stacked pin group. Do not show NC box on pins for
different components with the same symbol.
If a schematic contains two symbols with the same name from different
libraries, the cache will contain the last symbol saved with that name.
Prepend the library nickname with the original schematic symbol library
nickname when saving the cache library to prevent name collisions.
With the implementation of the legacy schematic plugin, any I/O error
when parsing the schematics would prevent the entire schematic from
being loaded. This change restores (somewhat) the previous behavior
where as long as the root schematic is loaded properly, then all of
the remaining sub-sheet will attempt to load.
Add GetError() method the SCH_PLUGIN object to allow for partial
schematic loading.
Check the error message contents when no exception was caught to warn
the user of any accumulated errors.
Fixes lp:1690644
https://bugs.launchpad.net/kicad/+bug/1690644
Fixes the connection display and dragging behavior of wires,
busses and their entries.
The implemented drag logic is:
-busses and bus-bus entries drag each other when connected at endpoints
-wires and wire-bus entries drag each other when connected at endpoints
-entries do not drag wires or busses when connected to wire middles
-wire-bus entries do not drag busses
The implemented connection logic is:
-bus-bus entries connect busses to busses but not wires
-wire-bus entries connect wires to busses but not wire to wires or
busses to busses
It turns out the fastest way to update wxDataViewCtrl is to nuke the
model and rebuild it from scratch rather than via
ItemAdded()/ItemDeleted() update notifications.
Fixes: lp:1734773
* https://bugs.launchpad.net/kicad/+bug/1734773
CHANGE: In Eeschema, when placing a component directly over an existing
wire, the wire is automatically removed where it shorted pins.
This helps workflow in Eeschema, allowing one to quickly add components
to existing lines.
Fixes: lp:1678449
* https://bugs.launchpad.net/kicad/+bug/1678449
This is the last of the object save/load code that was not moved into
the SCH_LEGACY_PLUGIN object. All schematic and library I/O is now
performed in the SCH_LEGACY_PLUGIN object and as been removed from the
schematic and library objects.
The old single symbol file format has been replaced with the normal
symbol library file format since there was no difference between them
except the SYMBOL token. The SYMBOL token was no longer being read
since the introduction of the SCH_LEGACY_PLUGIN symbol library loader.
Update the Doxygen comments in all of the modified files.
BreakSegment now breaks a known segment and BreakSegments
breaks all segments. This allows functions to break a
segment without needing to iterate through the whole list.
Changes to the schematic shouldn't be made
where the user isn't looking. Removing the
cleanup in ERC and netlisting prevents
unintended consequences
CHANGE: ERC and Netlist calls do not modify schematic
SCH_LINE can represent a bus, wire or graphic line. Checking
for the corner needs to distinguish between these types.
Fixes: lp:1635984
* https://bugs.launchpad.net/kicad/+bug/1635984
Make the user prompt an HTML control for improved layout.
Fix some column title sizing issues. This is not a complete fix but
it seems better than the default sizing done by wxWidgets.
Use symbol terminology instead of part and/or component.
Create trace string source files for a common place for them and their
Doxygen comments.
Don't back up schematic files unless the user requests a remap.
Back up all files that could be changed by a remap including the
schematic file(s), cache library, project file, and rescue library
files.
Use an HTML control instead of a static text control for improved layout
of the user remap prompt.
Improve the user prompt in the remap dialog to make it clear that changes
will be made to project files.
Duplicated aliases were given " (copy x)" suffix. There are two
problems: aliases cannot contain spaces and the string was translatable
which could create more issues. Now duplicated aliases receive "_x" suffix.
Change the legacy schematic plugin to preserve illegal LIB_ID characters
when load schematics prior to version 4.
Check for illegal LIB_ID symbol names during project rescue. Rename and
rescue any symbols with illegal LIB_ID names.
Add static methods to LIB_ID object for testing for and fixing names
with illegal characters so there is uniform code for doing so.
Update the Eagle plugin symbol loader to fix symbol names using the new
LIB_ID fix illegal names method.
Fixes lp:1732236
https://bugs.launchpad.net/kicad/+bug/1732236