Change teardrop generation to rely more heavily on BOARD_CONNECTIVITY
for improved performance.
Add updating of teardrops on BOARD_COMMIT::Push().
Also converts m_CopperItemRTreeCache to std::shared_ptr.
We don't copy it around anyway, and having to create a new set
of std::unique_ptr's for each operation is likely to be more
expensive than std::shared_ptr's overhead.
SCH_CONNECTION objects are temporary and can become stale any time the
connectivity is updated. Keeping them around to reference later is a
bad idea. Even if the object pointer is still valid in an SCH_ITEM in
the undo/redo buffers, comparing the pointer against another pointer as
a test to see if they are the same connection is not valid. Saving the
connection name is safe and ensures the connection is the same even if
the pointers differ.
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
Also simplifies the scoring algorithm so that it only
differentiates between exact-match, match-at-start and
any-match. The rest of the position-based matching
stuff is gone, as is the knowledge of the name vs the
keywords vs the description. All that is left to the
provider of the weighted search terms array.
Provides a single-point access for modifying the schematic and symbol
elements that allows chaining updates and reverting partial changes.
Standardizes the undo hierarchy between pcb and schematic editors
As this is another layer on the existing undo/redo structure, the
initial commit does not replace all undo/redo calls currently existing.
These will be handled in a series of follow-on commits
- Ensure a change in plugin type is detected
- do not force automatic plugin type selection for *.lib files that need
an access to these libraries: they can be not always available.
in GetMsgPanelInfo() (PPI, scale).
m_image name was confusing: it is not a wxImage, but a BITMAP_BASE item,
and m_image name was already in use in BITMAP_BASE, used inside SCH_IMAGE.
Bitmap properties dialog: show PPI value and add Title to dialog.
- Ensure that critical paths (ERC/netlister) are fully-rechecked
- Handle symbol/pin distinction in change markers
- Fully connect hierarchical pins in one pass descending
Previously, almost all connectivity updates were full updates, meaning
that the entire connectivity graph would be rebuilt each time a change
was made to the schematic. This update modifies the update to only
correct the subgraphs that are directly affected by the change.
It uses the existing connection graph to find all affected subgraphs as
well as connections to the changes based on the visible schematic.
These elements are removed from the existing connectivity graph and
marked dirty. They then have a new connectivity graph built only around
their changes. The resulting graph is merged into the original.
Currently, this ability is behind an advanced config flag
`IncrementalConnectivity` while testing.
Fixes https://gitlab.com/kicad/code/kicad/issues/10846
Fixes https://gitlab.com/kicad/code/kicad/issues/1794
Adds maximum step size setting used by transient analysis solver,
and 'use initial conditions (uic)' setting. Enabling uic disables
DC operating point analysis and may introduce singularities. It requires
a careful selection of initial conditions of circuit elements.
Fixes https://gitlab.com/kicad/code/kicad/issues/2515
Previously, bus elements that were not instantiated as individual nets
could not connect to each other. This caused issues for complex
schematics where busses needed to connect to other busses with elements
that resolved to the same net names. Functionally, this means mixing
bus elements, which we will replace with first-class elements in version
8 but currently can only be accomplished either by using bus aliases and
this patch or by individually instantiating each bus element as a
local label
Fixes https://gitlab.com/kicad/code/kicad/issues/14300