- Ensure that critical paths (ERC/netlister) are fully-rechecked
- Handle symbol/pin distinction in change markers
- Fully connect hierarchical pins in one pass descending
Also makes the strings match the GUI better so people will know where
to find them later.
And fixes a couple of ERC items that referred to Board Setup (oops).
Don't assume the dialog is mode-less and call Destroy() from within a
dialog method. This will most assuredly crash if the dialog is shown
modally or quasi-modally.
Don't leak memory for mode-less dialogs created on the stack. Make sure
when the parent frame window is closed that all mode-less dialog memory
is cleaned up. Dialogs are not child windows like controls and toolbars
so their memory does not automatically get cleaned up when the parent
window is destroyed.
Do not directly access frame parent window's pointer in dialog destructors.
Apparently the tear down order when destroying mode-less dialogs is not
guaranteed so the parent window may get deleted before the dialog causing
a crash when accessing the parent window pointer from the dialog dtor.
Do not close mode-less dialogs in the parent frame's destructor. This
doesn't guarantee that the dialog(s) will be destroyed before the parent
but it may reduce some careless mode-less dialog event handling in the
future.
Fixes#10926
Contains the following changes:
- Adds a new ERC_SCH_PIN_CONTEXT class which is used to provide deterministic
comparison between items causing ERC violations (e.g. pins) when associated
with a SCH_SHEET_PATH context.
- Adds association of SCH_SHEET_PATHs for ERC_ITEMs and the sub-schematic items
which caused an ERC violation. This allows correct display of markers on the
sheets of interest only, and allows correct naming resolution and cross-probing
from the ERC dialog.
- Adds a new ERC_TREE_MODEL class, derived from RC_TREE_MODEL, which correctly
resolves component references across heirarchical sheets using the associated
SCH_SHEET_PATHs. This allows sheet-specific component references to be displayed
correctly in the ERC results tree.
- Updates SCH_MARKER to only draw sheet-specific markers on the sheet causing
an ERC violation.
- Increments the schematic file version.
- When loading a schematic with legacy ERC exclusions, discards those of type
ERCE_PIN_TO_PIN_WARNING, ERCE_PIN_TO_PIN_ERROR, ERCE_HIERACHICAL_LABEL, and
ERCE_DIFFERENT_UNIT_NET as there is no safe way to automatically infer the
information which is now stored with these exclusions (sheet paths for error
location and related items). Requiring users to (once) re-add exclusions is
preferable to silently incorrectly matching new ERC issues to legacy exclusions.
Reports a warning (by default) for missing units
Reports an error for missing units with power input pins
Reports a warning for missing units with input pins
Reports a warning for missing units with bidi pins
Fixes https://gitlab.com/kicad/code/kicad/issues/1922
Unconnected items and schematic partity violations are also now
represented by markers, so the ERC/DRC window itself needs to do
the deep-delete.
Fixes https://gitlab.com/kicad/code/kicad/issues/12182
Better to have both the single-pin error message and the non-driven
error message when an input pin is not connected than miss error
messages when the pin is connected to a blank net
Fixes https://gitlab.com/kicad/code/kicad/issues/10430
(cherry picked from commit e740db61f5)
This can be a particular problem if you go to run ERC, it shows the
annotation warnging so you re-annotate (but don't notice that your
scope is set to Selection).
Also adds some missing defensive code around closing a modeless RC
checker before the document (which we had for DRC dialog but not the
ERC dialog).
Also fixes a missing override of GetSeverity which kept ERC messages
from having the right prefix.
They don't define a KiCad string class, so the header file name was
somewhat misleading. But the fact that they didn't match definitely
made coding more difficult.