Setting the active layer should be tied to the events that are triggered
by the layer change and overloaded for each frame. This ties the hotkey
back to these events.
Fixes: lp:1838244
* https://bugs.launchpad.net/kicad/+bug/1838244
Previously, for instance after modifying preferences or language,
they were rebuilt but the tools state was not set due to a missing call to SyncToolbars() after rebuilding.
The 3D viewer also uses OpenGL, so it also needs to
adjust based on DPI scale factors.
This patch moves the 3D viewer common config code solely
within the 3D viewer, and adds handling of the DPI scale. This
also avoids duplicated logic in PCB_BASE_FRAME::CommonSettingsChanged.
For now, as EDA_3D_VIEWER is not included in the Kiway settings
dispatch, still manually invoke the settings update from
PCB_BASE_FRAME.
The PANEL_3D_PREV gets a similar function to read the config, but
it doesn't have a listener for the update, so it's set just once
at dialog init, just like the existing pan settings.
Fixes: lp:1823681
* https://bugs.launchpad.net/kicad/+bug/1823681
Previously, when the 3D viewer is opened, each board edition creates a 3D view refresh, that usually takes a bit of time.
Now the refresh is postponed until the 3D viewer has the focus.
The config was saving a canvas type EDA_DRAW_FRAME member not always accurately initialized.
And the last canvas opened frame setup was saved, not necessary a frame having a canvas type that can be set by user.
This is a broken feature especially because the footprint viewer has a fixed canvas setting.
wxChoice centers the selection on GTK. So when switching from a
mid-list item to an item at the top, the list is always cut off for
choice lists located on the top toolbar. Using a combobox provides a
drop-down that allows easier access to all elements in the box.
Fixes: lp:1808569
* https://bugs.launchpad.net/kicad/+bug/1808569
Add Display Settings to Footprint Browser.
Make each of them OpenGL on OSX and Cairo on other platforms.
Allow auto-zoom to be turned off and save last zoom setting.
Make ordering of tools in htoolbar consistent.
Standardize grid and zoom drop-downs.
Fixes: lp:1791667
* https://bugs.launchpad.net/kicad/+bug/1791667
Primary change is to replace most control/window borders with
AUI pane borders. We implement our own AUI border drawing
routine which avoids the ugly one-pixel white frames around
dark canvasses.
Also increases the signal-to-noise ratio of all the pane
creation code in the various frames.
... and GetMsgPanelInfo.
Step 4 in the g_UserUnit eradication effort.
Also removes a couple of conversion routines that were close
enough to extinction.
(cherry picked from commit c75da51)
Step 1 of the g_UserUnit global eradication. This commit includes
basic hookup of hotkeys, units tool-buttons and grid dialogs.
(cherry picked from commit e0500ab)
* Refresh the view only when changes are made in the caller frame.
* Allows recreate a new instances when try to open the 3D view from a frame taht is not the initial caller
* Remove duplicate code in kicad frames.
Frame, dialog and config file couldn't agree on whether to use
internal units or not.
Frame now stores internal units, and they're now mapped on the
way in/out of the config file. Dialog was already assuming they
were stored in internal units (though they were previuosly not).
Fixes: lp:1751435
* https://bugs.launchpad.net/kicad/+bug/1751435
Fixes a bunch of errors:
- libedit and libbrowser would zoom to bounding box but centre on canvas
- libedit, libbrowser and gerbview didn’t take the scroll bars into account
- pcbnew didn’t take scroll bars into account or apply the 10% margin
- appending a board file would re-centre, but not re-zoom
Fixes: lp:1504302
* https://bugs.launchpad.net/kicad/+bug/1504302