Better to have both the single-pin error message and the non-driven
error message when an input pin is not connected than miss error
messages when the pin is connected to a blank net
Fixes https://gitlab.com/kicad/code/kicad/issues/10430
(cherry picked from commit e740db61f5)
Before they were 1/2 treated as flags and 1/2 treated as a mode enum.
The ERC flag relaxes constraints on data that is settable in the
schematic editor.
Fixes https://gitlab.com/kicad/code/kicad/issues/11018
Also fixes some plot bugs with arcs.
Also moves polygonization of arcs (when required) in plotting code
from 5 degrees to calculated based on ARC_HIGH_DEF.
Fixes https://gitlab.com/kicad/code/kicad/issues/5017
They don't define a KiCad string class, so the header file name was
somewhat misleading. But the fact that they didn't match definitely
made coding more difficult.
SCH_PIN wasn't handling the legacy empty string token (~), but
more importantly this will allow text variable resolution specific
to the schematic.
Fixes https://gitlab.com/kicad/code/kicad/issues/8625
This fix required sorting all of the LIB_PART draw items to ensure
accurate comparison between the symbols stored in the schematic and the
original library symbols. This has a noticeable impact on symbol library
load performance. It may also cause significant changes the next time
the library is saved due to changes in the draw item sorting. Hashing
may be a better solution here but this addressed the immediate problem.
A skeleton method SCH_SCREEN::SwapSymbolLinks() was added because there
is most likely an issue with orphaned symbols in the schematic library
symbol cache during undo/redo operations. More testing is required to
verify this.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7263
Input pins can be driven by many pin types: output, passive, 3state, I/O
But Power pins can be driven by only power output pins, and cannot
use the same criteria in ERC tests.
The groundwork has now been laid for per sheet instance data. Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.
ADDED: Support for user defined schematic page numbers.
Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)
Fixes https://gitlab.com/kicad/code/kicad/issues/5397