Prior to this change, the schematic connectivity was updated any time a
change was made to a connectable object. Now the connectivity is only
updated when an object change actually affects the connectivity. Other
properties like line width, fill type, custom fonts, etc. will not cause
the connectivity graph to be rebuilt.
The SCH_COMMIT flag SKIP_CONNECTIVITY has been removed. All schematic
objects can test if they are connectable and if there have been changes
to any connection properties that require a connectivity rebuild.
Remove duplicate rebuild connectivity calls from editor control tool.
This was causing the tangling end test to get called four times on every
undo and redo action because the dangling end test is already called in
the connectivity graph calculation code.
Update connectivity when changing label names which fixes an unreported
connectivity bug.
(cherry picked from commit c5a02fc266)
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
Previously, almost all connectivity updates were full updates, meaning
that the entire connectivity graph would be rebuilt each time a change
was made to the schematic. This update modifies the update to only
correct the subgraphs that are directly affected by the change.
It uses the existing connection graph to find all affected subgraphs as
well as connections to the changes based on the visible schematic.
These elements are removed from the existing connectivity graph and
marked dirty. They then have a new connectivity graph built only around
their changes. The resulting graph is merged into the original.
Currently, this ability is behind an advanced config flag
`IncrementalConnectivity` while testing.
Fixes https://gitlab.com/kicad/code/kicad/issues/10846
Fixes https://gitlab.com/kicad/code/kicad/issues/1794
The list of candidates (names) must be restricted to existing global labels
and symbols creating a global net name: power symbols having only one power
input pin (a power output does not create net name).
Fixes#14319https://gitlab.com/kicad/code/kicad/issues/14319
This is mainly for simulation testing where the dialog has to be
grown every time you restart the app, but it might as well be applied
to the similar dialogs.
Fixes https://gitlab.com/kicad/code/kicad/issues/12887
1) Copy label fields when converting.
2) Don't assume netclass directive should be net name -- this is very
unlikely.
3) Don't show font controls in Netclass Directive Properties dialog --
there's no basic text associated witha Directive Label.
This is mostly to output the aliases sorted (for ease of VCS integration),
but also because a btree will be faster than hashing on a small dataset.
Fixes https://gitlab.com/kicad/code/kicad/issues/11890
It hasn't worked since we rejiggered the default grid selection mode
anyway, and for some reason it eats <esc> key events after the dialog
has been resized.
Fixes https://gitlab.com/kicad/code/kicad/issues/11015
Also fixes some plot bugs with arcs.
Also moves polygonization of arcs (when required) in plotting code
from 5 degrees to calculated based on ARC_HIGH_DEF.
Fixes https://gitlab.com/kicad/code/kicad/issues/5017