- Add a test to be sure a SCHEMATIC exists before trying to use it
- Delete items in Repeat list and undo/redo list before deleting the schematic
- Delete also these items when loading a new schematic (the repeat list was
not cleaned previously)
( include qa compatibility from master )
Before these fixes I saw a use after delete issue due to dangling pointers
stored in Repeat list.
From master branch
Also fixes a bug where ERC testing for text variables in sheet pins
would start with the wrong sheet.
Also fixes a bug where ERC testing of similar labels would use the
wrong sheet.
Also fixes a bug where ERC testing of bus-to-net conflicts would use
the wrong sheet.
Also fixes a bug where ERC didn't process variable references when
checking hierarchical labels against sheet pins.
Also fixes a bug where ERC multiple-drivers and netclass-conflicts
tests didn't set a sheetpath.
Fixes#10926
Contains the following changes:
- Adds a new ERC_SCH_PIN_CONTEXT class which is used to provide deterministic
comparison between items causing ERC violations (e.g. pins) when associated
with a SCH_SHEET_PATH context.
- Adds association of SCH_SHEET_PATHs for ERC_ITEMs and the sub-schematic items
which caused an ERC violation. This allows correct display of markers on the
sheets of interest only, and allows correct naming resolution and cross-probing
from the ERC dialog.
- Adds a new ERC_TREE_MODEL class, derived from RC_TREE_MODEL, which correctly
resolves component references across heirarchical sheets using the associated
SCH_SHEET_PATHs. This allows sheet-specific component references to be displayed
correctly in the ERC results tree.
- Updates SCH_MARKER to only draw sheet-specific markers on the sheet causing
an ERC violation.
- Increments the schematic file version.
- When loading a schematic with legacy ERC exclusions, discards those of type
ERCE_PIN_TO_PIN_WARNING, ERCE_PIN_TO_PIN_ERROR, ERCE_HIERACHICAL_LABEL, and
ERCE_DIFFERENT_UNIT_NET as there is no safe way to automatically infer the
information which is now stored with these exclusions (sheet paths for error
location and related items). Requiring users to (once) re-add exclusions is
preferable to silently incorrectly matching new ERC issues to legacy exclusions.
EDA_ITEMs are responsible for giving their parent a crack at it if
they failed to resolve it. This recurses all the way up to the schematic/
board, and then to the project.
Cross-reference handling is also move to the EDA_ITEMs. It must be done
before bubbling up so that we don't end up in loops. (The aDepth parameter
will break the loop, but without having done anything useful.)
Fixes https://gitlab.com/kicad/code/kicad/issues/13541
This is mostly to output the aliases sorted (for ease of VCS integration),
but also because a btree will be faster than hashing on a small dataset.
Fixes https://gitlab.com/kicad/code/kicad/issues/11890
The legacy and s-expression (prior to version 20200828) file formats only
supported symbol unit and reference fields so the newly added value and
footprint fields must be updated from the original symbol fields.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12226
1) Move a bunch of std::map's to std::unordered_map to get constant-time
look-ups
2) Lengthen progress-reporting intervals to spend more time doing work
and less time talking about it
3) Reverse order of SHAPE_LINE_CHAINs in thermal intersection checks to
make (much) better use of bbox caches
4) Don't re-generate bboxes we already have
5) Fix some autos that weren't by reference (and were therefore copying
large datasets)
6) Rename delta progressDelta so it's easier to search for in future
7) Get rid of a few more autos (because I don't like them)
8) Pass large items to lambdas by reference
Fixes https://gitlab.com/kicad/code/kicad/issues/12130
CHANGED: The text variable ${SHEETNAME} now always represents the name of the
sheet when used anywhere in the schematic editor, including the title block
ADDED: A new text variable ${SHEETPATH} which is replaced with the path to the
current sheet - e.g. "/Sheet 1/Sheet 2".
To ensure backward compatibility, the default drawing sheet now uses
${SHEETPATH}. Custom drawing sheets will need to be manually edited.
Always use full sheet paths when storing sheet instances. Partial sheet
paths cannot be full resolved resulting in lost page numbers when renaming
sheet file name.
Fixes#9782
Remove duplicate instance data saved in both root SCH_SCREEN and SCH_SHEET
objects that was causing them to be out of sync. All sheet instance data
is stored in the SCH_SHEET object itself and rebuilt on the fly so it is
always current.
Remove Get/SetPageNumber from SCH_SHEET_PATH object so it doesn't obfuscate
where the actual sheet page number information exists.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/9782
Also removes the message bar display of assigned netclass for
buses and bus-to-bus entries.
Also fixes a bug where assigning a netclass via the canvas only
looked at the first level of bus members (and not any nested
members).
Also fixes a bug where the bus name validator tried to validate
a vector bus first -- which doesn't work as a vector bus may be
nested in a group bus.
Also fixes a bug where we were failing to check for illegal
chars in bus definitions which otherwise passed the bus parsers.
See additional comments in the bug report.
Fixes https://gitlab.com/kicad/code/kicad/issues/9160
1) Fix a couple of bugs in case processing
2) Make case processing more explicit to prevent more (1)
3) Move label processing to AltiumSpecialStringsToKiCadVariables
4) Strip double-quotes from special strings (and add test cases)
5) Change PROJECTNAME to just filename, not full path
6) PROJECTREV and REVISION are two different things
7) Add support for Altium's Application_BuildNumber
8) Fix some issues in trimming spaces around special strings
ADDED CURRENT_DATE titleblock token (to go with existing ISSUE_DATE)
ADDED PROJECTNAME schematic token (to go with FILENAME and SHEETNAME)
Converts other parameters to project text variables.