The variable `m_Initialized` in `BASE_SCREEN` is used by
`SCH_EDIT_FRAME` to mark whether a screen had its zoom level initialized
by the "zoom to fit screen" action. When this variable is `false`, the
function `SCH_EDIT_FRAME::DisplayCurrentSheet()` performs "zoom to fit
screen", modifying the zoom level. This function is indirectly called in
the undo routines, so if `m_Initialized` is not set to `true`, a zoom
change will occur when the user undoes an operation, a behavior that is
undesired.
`m_Initialized` was not initialized to `true` for the null schematic
(the schematic that is loaded if no project is loaded), causing the
aforementioned undesired behavior.
To prevent this, I've changed the `SCH_EDIT_FRAME` constructor to set
`m_Initialized` to `true`, since it zooms to fit screen already. I've
moved `m_Initialized` from `BASE_SCREEN` to `SCH_SCREEN`, as it is used
only in Eeschema, and renamed it to `m_zoomInitialized`, a name I
believe that better describes what this variable does.
I've also introduced the function `SCH_EDIT_FRAME::initScreenZoom()` to
group the "zoom to fit screen" action with setting `m_Initialized` to
`true`, as they often should occur together.
I'd also like to say that I'm not confident whether
`SCH_EDIT_FRAME::DisplayCurrentSheet()` should perform the zoom level
initialization at this point, but I have decided to not change this
behavior for now, as the commit history suggests it's several years old.
Fixes https://gitlab.com/kicad/code/kicad/issues/7343
1) Zero out selection in tree when canvas captures focus so that
save/save as actions will go to canvas, not tree item.
2) Make save do a save to schematic when the canvas symbol is from
the schematic.
3) Copy fields when doing a save to schematic (setting the lib part
doesn't update them on its own).
4) Remove no-longer-necessary calls to update schematic after
saving symbols (the schematic symbols are no longer hot-linked).
Fixes https://gitlab.com/kicad/code/kicad/issues/6763
In theory, the WM should now choose the closest size icon for its
purpose, making it easier to distinguish in space-constrained settings
Fixes https://gitlab.com/kicad/code/kicad/issues/6798
- update hierarchy navigator after any modifications to the SCH_EDIT_FRAME
- do not generate ghost selection events after updating hierarchy tree
- use Human Readable path in SCH_EDIT_TOOL::EditPageNumber
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5760
1) init reference pages before trying to draw the SCH_FIELDs when
turning intersheet references on
2) don't double redraw because we accidentally cleared the last
hover item on a non-mouse-moved event.
3) make sure the root sheet gets a name for the hypertext menu.
1) Generalize SCH_ITEM owners (SCH_COMPONENT, SCH_SHEET, and now
SCH_GLOBALLABEL)
2) Generalize hypertext items
3) Use SCH_FIELD autoplace infrastructure for placing intersheet
references
4) Use textVar infrastructure for buildin intersheet references.
As an important side-effect this also fixes the undo issues with
intersheet refs.
The groundwork has now been laid for per sheet instance data. Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.
ADDED: Support for user defined schematic page numbers.
This will always show 1 unit from each system, with the primary unit
being the current frame unit and the secondary unit being the
most recent unit used from the other system. These are saved in
the settings, so they are saved between runs.
CHANGED: GetDocumentExtents() in 'eda_draw_frame.h' now has a bool
parameter "aIncludeAllVisible" with a default value "true" which makes
it behave as it did before adding parameter. If "aIncludeAllVisible"
is false, the returned bbox ignores some items depending on which
program it is running in.
CHANGED: Made "Zoom to Objects" use only PCB edge in Pcbnew. This
allows text, notes, etc outside the PCB edge to be excluded in the
zoom calculation.
CHANGED: Added "Zoom to Objects" to Pcbnew main menu, and to RMB context
menus for Eeschema and Pcbnew.
Fixes https://gitlab.com/kicad/code/kicad/issues/5787
Eeschema was the only application showing the file path. This is of
limited use and prevented other information from showing in the
shortened menubar display. Also combined strings for better translation
This may affect other EDA_DRAW_FRAME objects as well but it doesn't seem
to be as noticeable in the symbol, footprint, and worksheet editors.
Fixes https://gitlab.com/kicad/code/kicad/issues/5248
The use of printf, wxLogDebug, and std::err/std::out causes excessive
debugging output which makes finding specific debugging messages more
difficult than it needs to be.
There is still some debugging output in test code that really needs to
be moved into a unit test.
Add debugging output section to the coding policy regarding debugging
output.
PROJECT objects will be deleted by SETTINGS_MANAGER::UnloadProject
so we need to make sure that this is called at an early enough point
in the closing process that anything needed by the PROJECT dtor
is still around.
Also fix an issue where the schematic worksheet was depending on
the project existing after the schematic had been reset.
We used to have to open a PCB_EDIT_FRAME to get the settings for
the footprint editor and footprint viewer. This necessitated some
special processing when opening a PCB_EDIT_FRAME to actually edit
a board as it might already be open but unloaded.
Since the new settings architecture allows the footprint editor and
footprint viewer to init themselves we no longer need the special-
case code.
- Fix file extension for new project
- Fixes for exceptions on MSW
- Fix some ASAN issues
- Allow SETTINGS_MANAGER to run headless
- Don't flag schematic as modified after schematic setup is closed
- Don't automatically unload projects when LoadProject is called
- Don't unload project if it's the same as the current one
- Make sure to properly init/de-init template field names
* Move it to a panel along with the canvas to have a better UI
* Allow the infobar to automatically close after a set time
CHANGED: The eeschema find notifications now use the infobar instead of
a popup window
This widget allows for non-intrusive display of text
above the editing canvas. Currently, this is used
for displaying the read only status of the files.
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of. Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
In order to avoid confusion when loading legacy schematics, updating time
stamp UUIDs is no longer performed. If users where not experiencing issues
with time stamp clashes with shared schematics then this was probably a
case of me being overly cautious.
The original conversion code has be moved to
SCH_EDIT_FRAME::ConvertTimeStampUuids() so the working functionality is
not lost. This function should not be used until a way is found to update
the board from the schematics with the appropriate settings.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.
The new file formats are now the default in both the schematic and symbol
library editors. Existing symbol libraries will be saved in their current
format until new features are added to library symbols. Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted. Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.
When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier. The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.
The next save after loading a legacy schematic file will be converted to
the s-expression file format. Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.
Appending schematics requires that the schematic to append has already been
converted to the new file format. This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.
The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol. This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed. It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.
When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded. Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.
Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically. No external manipulation of this library cache should ever
occur.
ADDED: S-expression schematic and symbol library file formats.